Seacom supplies industrial thermometers, temperature probes, data loggers, transmitters, recorders and calibration equipment for portable measurements, production processes, laboratories, food manufacturing, HVAC systems, cold storage and regulated facilities.
The correct temperature instrument depends on the measurement target, temperature range, required accuracy, response time, sensor type, number of channels and whether the application requires local indication, data logging, alarms or connection to a control system.
Choose the Correct Temperature Instrument
Handheld contact thermometers: Portable temperature checks using an application-specific surface, air, liquid, penetration or moving-object probe.
Temperature probes: Thermocouple, RTD and specialised sensors designed to make reliable contact with the actual measurement target.
Multi-channel data loggers: Record several measurement points together for temperature profiling, validation and equipment troubleshooting.
Temperature transmitters: Continuous measurement with analogue or digital outputs for PLC, BMS and process-control systems.
Infrared thermometers: Non-contact measurement where the surface is moving, very hot, inaccessible or unsafe to touch.
Environmental data loggers: Record temperature or temperature and humidity in warehouses, laboratories, cold rooms and production areas.
Continuous monitoring systems: Centralised records, alarms, audit trails and reports for pharmaceutical, healthcare and other regulated facilities.
Temperature calibration equipment: Verification and calibration of thermometers, probes and temperature sensors at defined test points.
Long-range VaiNet wireless logging with local memory and integration into the Vaisala viewLinc system.
Selecting the Right Temperature Probe
The thermometer and probe must be selected as one measurement system. A highly accurate indicator cannot compensate for poor sensor contact, unsuitable probe construction or incorrect installation.
Stationary surfaces: Use the Anritsu SX Series. Its flexible sensing head follows the target surface and maintains reliable contact even when probe alignment is not perfectly perpendicular.
Moving or rotating surfaces: Use the Anritsu UX Series for rollers, belts and other moving or rotating targets. Its contact-support design helps stabilise the sensing head during measurement.
Air temperature: Use the Anritsu AT Series. Different sensing-head constructions are available to balance response time, durability and maximum operating temperature.
Liquids and process gases: Use the Anritsu SHEATH Series. Select the sheath diameter, material, thermocouple type, junction, immersion length and optional chemical-resistant coating according to the process.
Food and soft materials: Use the waterproof Anritsu BC Series for hygienic centre-temperature measurement of food, liquids and semi-solid products.
High-temperature surfaces: Use the Anritsu HHT Series. Confirm the continuous temperature limits of the sensing head, sheath, handle and cable before selection.
High-frequency, microwave or high-voltage environments: Use the Anritsu FL Series Fibre-Optic Thermometer where conventional metallic thermocouple or RTD sensors may be unsuitable.
Information Required for Temperature Instrument Selection
Measurement target: State whether the sensor will measure a surface, moving object, air, gas, liquid, food, chamber or process connection.
Temperature range: Provide the normal, minimum and maximum temperatures at the actual sensing point.
Accuracy and resolution: Define the acceptable measurement uncertainty and display resolution for the application.
Response time: Indicate whether the process changes slowly or requires rapid detection of temperature variation.
Number of points: Confirm whether one channel or simultaneous multi-point measurement is required.
Recording requirement: Specify local reading, internal logging, printed record, computer download or continuous network monitoring.
Output and communication: Identify requirements for 4–20 mA, voltage, relay, Modbus, Ethernet, wireless or system integration.
Calibration: State the required calibration points, certificate type, acceptance tolerance and recalibration interval.
Installation conditions: Include probe dimensions, cable length, mounting connection, ingress protection, vibration and hazardous-area requirements.
Common Temperature Measurement Applications
Manufacturing and maintenance: Machine surfaces, bearings, motors, moulds, rollers, production lines and equipment troubleshooting.
Pharmaceutical and life sciences: Warehouses, refrigerators, freezers, incubators, laboratories and regulated storage areas.
HVAC and data centres: Duct air, chilled-water pipes, cooling systems and environmental monitoring.
Heat treatment and ovens: Multi-point profiling, furnace surveys, dryers and thermal-process validation.
Research and calibration: Laboratory experiments, reference comparisons, sensor verification and cryogenic measurements.
Need Help Selecting a Temperature Instrument?
Contact Seacom with the measurement target, temperature range, required accuracy, response time, number of channels, recording method, output signal and calibration requirements. Our team can recommend a suitable thermometer, probe, transmitter, data logger or monitoring system for your application.
The Anritsu AP-400 Series combines a high-accuracy thermocouple thermometer with a built-in thermal printer. Measurements can be printed immediately, printed automatically at selected intervals or stored and printed later.
Single-channel handheld thermometer with built-in printer
Manual, interval and sequential-number printing
Stores up to 100 measurements for batch printing
AP-400 supports Type E or K with an ASP connector
AP-450 supports Type E, K, J, T or R with an ANP connector
Thermocouple type is selected when ordering and is not switchable
Powered by four AA batteries or an optional AC adaptor
The Sato Baromex 7612-00 combines an easy-to-read analogue barometer with a digital thermometer for local atmospheric-pressure and room-temperature indication.
Atmospheric-pressure range from 945 to 1045 hPa
Dual pressure scale in hPa and mmHg
Movable index pointer helps indicate pressure change
The Sekonic ST-50A displays temperature and relative humidity and records both on a continuous paper chart.
Electronic temperature and humidity sensing with LCD display.
Optional extension cables for remote sensor placement.
Battery operation or a suitable external DC supply.
Desktop or wall-mounted installation.
Being phased out: confirm availability before ordering. Alternatives include the Sato Sigma II for paper records, Sato SK-L754 for electronic logging and Vaisala viewLinc for centralised monitoring.
The Sekonic ST-50M digital thermohygrograph is discontinued. It combined temperature and humidity measurement with paper chart recording and SD-card storage.
Paper records: consider the Sato Sigma II NSII-Q.
Electronic records: consider the Sato SK-L754 temperature and humidity data logger.
Centralised monitoring and alarms: consider Vaisala RFL100, AP10 and viewLinc.
Contact Seacom to match the replacement to your recording requirements. Features and accessories differ from the original ST-50M.
The Sato Thermohygrograph Sigma II NSII-Q continuously records temperature and relative humidity on an easy-to-read paper chart, providing a visible record without requiring a computer or network.
Temperature ranges of −15 to +40 °C or −10 to +50 °C
Relative-humidity range from 0 to 100 %RH, non-condensing
Selectable 1-day, 7-day or 32-day chart rotation
Transparent cover allows the chart to be viewed while closed
Battery-powered quartz clock with no external supply required
Suitable for warehouses, laboratories, clean areas and production rooms
The compact Vaisala HM40 Series provides reliable humidity and temperature spot checks for HVAC, construction, warehouses, laboratories, museums and industrial applications.
The Vaisala PTU300 combined barometric pressure, relative humidity and temperature in one transmitter. The series is discontinued and has been replaced by a suitable Indigo520 barometric-pressure configuration with an application-specific HMP probe.
Legacy three-in-one pressure, humidity and temperature transmitter
PTU301, PTU303, PTU304, PTU305, PTU307 and PTU308 variants
Former applications include laboratories, meteorology and semiconductor measurement
Current replacement platform: Indigo520 with barometric-pressure measurement
Humidity probe selected according to mounting and process conditions
Existing wiring, outputs and process connections require migration review
The Vaisala HMT120 and HMT130 provide accurate, stable humidity and temperature measurement for cleanrooms, laboratories, data centres and demanding HVAC applications.
Product transition: HMT120/HMT130 are expected to be phased out. For new projects, the Vaisala Origo10 is the recommended replacement platform.