Indicating flow meters provide a local reading for operators checking flow through equipment, pipework and process systems. This category includes instruments for liquid or gas service, with the suitable technology depending on the fluid and operating conditions.
Options include glass or acrylic tube meters, metal tube variable-area meters and electronic flow meters with displays. Not every model measures both liquids and gases; select a meter calibrated and configured for the intended service.
Choose the Right Instrument Type
Instrument type
Typical purpose
What to check
Purge and panel flowmeter
Local indication of small flows in equipment, sampling and purge systems.
Calibrated fluid, scale range, valve position, mounting and connections.
Glass or acrylic tube flowmeter
Direct visual flow readings for compatible liquids or gases.
Tube and seal compatibility, temperature, pressure and installation orientation.
Metal tube variable-area flowmeter
Local indication where operating conditions require a suitable metal measuring tube.
Fluid properties, construction materials, pressure rating and optional electrical outputs.
Electronic flowmeter with display
Local readings with options for remote monitoring or totalisation.
Measurement principle, fluid suitability, power supply and output requirements.
GTF, ATF, GTV and ATV: tube-type variable-area families with different construction and connection options.
ADF, GDF and GDR: water-flow indication across model-specific measuring ranges.
EM Series: metal tube flowmeters with local indication and optional outputs, depending on configuration.
Information Needed for Selection
Fluid: state the liquid or gas, composition and relevant properties.
Flow: provide the required range and units. For gases, specify whether the values refer to actual or reference conditions.
Pressure and temperature: include normal and maximum operating conditions.
Installation: confirm pipe connections, mounting orientation, available space and viewing access.
Control: specify whether you need indication only, a regulating valve, alarms or remote outputs.
Variable-area scales depend on the calibration conditions. A scale for one fluid or gas pressure should not be assumed accurate for another without checking the applicable correction or calibration.
Contact Seacom with your fluid, required flow range, operating pressure and temperature, connections and mounting arrangement. For a replacement, include the existing model number and a photograph of its scale.
The Ryutai Kogyo MCF and E-MCF references relate to earlier metal tube flowmeters and transmitters. This page supports existing instrument identification and replacement enquiries.
For current options, see the Ryutai Kogyo EM Series. Confirm the complete model, flow range, connections and electrical requirements before selecting a replacement.
The TOKICO PFA ultrasonic vortex flowmeter measures compatible chemicals, corrosive liquids and ultrapure water using PFA liquid-contacting construction.
No moving parts.
Connection sizes: 3/8, 1/2, 3/4 and 1 inch.
Fluid temperature range: 0–100°C.
Flow range and pressure rating depend on size and operating conditions.
Local display with output functions according to configuration.
The Badger Meter ModMAG M2000 measures conductive liquid flow, with applications in data centre chilled-water and cooling-water systems. Communication options support integration with building and plant monitoring systems.
Flow velocity range: 0.03–12 m/s
Accuracy: ±0.20% of reading ±1 mm/s with suitable straight pipe
Integral or remote transmitter arrangements
BACnet, Modbus and other communication options
Zero-straight-run capability subject to specified conditions
Kofloc RK120XM Flow Meter for Gas Mixing combines two to four variable-area flowmeters into one compact unit for simple multicomponent gas mixing.
Each gas line has an individual inlet, calibrated flow scale and precision needle valve. The individually adjusted gases combine and leave through a common mixed-gas outlet.
Mixing of two to four gas lines
Individual flow indication and adjustment for each gas
Flow ranges from 50 mL/min to 10 L/min
Maximum 10 L/min per line and 20 L/min total
Standard accuracy of ±2% full scale
Precision non-rotating needle valves
Brass or stainless-steel construction
Suitable for laboratory and research gas mixing