Anritsu FL Series Fiber Optic Thermometers – FL-2000 & FL-2400

The Anritsu FL Series uses fiber optic probes to measure temperature in microwave, high-voltage and strong electromagnetic environments where conventional electrical probes may be unsuitable.

  • FL-2000: one measurement channel.
  • FL-2400: four measurement channels.
  • 0.1°C resolution.
  • Probe options for chemicals, intense light, high temperatures and semisolid samples.
  • Analog output and RS-232C communication.

Probes are ordered separately. The usable temperature range depends on the selected probe.

Anritsu FL Series Fiber Optic Thermometers

The Anritsu FL Series measures temperature using dedicated fiber optic probes in applications exposed to microwaves, strong electromagnetic fields or high voltages. Choose the FL-2000 for one measurement channel or the FL-2400 for four channels.

The optical sensing method provides an alternative where electrical interference makes conventional temperature probes difficult to use. Select the probe for the actual temperature, material and installation conditions.

Key Features

  • One-channel and four-channel instrument options.
  • 0.1°C resolution.
  • Dedicated probes for general use, chemicals, intense light, high temperatures and semisolid samples.
  • Analog temperature output and RS-232C communication.
  • AMS-850 software for transferring measurements to a PC.

Compare FL Instruments

SpecificationFL-2000FL-2400
Channels 1 4
Instrument range −195.0 to 450.0°C −195.0 to 450.0°C
Internal memory Up to 15,000 readings at one-second intervals No internal memory
Power Specified AC supply or six AA alkaline batteries Specified AC supply
Approximate power consumption 12 VA 40 VA
Dimensions, excluding protrusions 210 × 88 × 230 mm (W × H × D) 320 × 99 × 280 mm (W × H × D)
Approximate weight 3 kg 5 kg

FL-2000 One-Channel Thermometer

Anritsu FL-2000 fiber optic thermometer

FL-2400 Four-Channel Thermometer

Anritsu FL-2400 fiber optic thermometer

Temperature probes are ordered separately. Specify the required AC supply when ordering: the existing specification lists 100, 115 or 230 VAC configurations.

Measurement Specifications

ParameterPublished specification
Resolution 0.1°C
Accuracy without calibration ±2°C from −195.0 to 399.9°C; ±5°C from 400.0 to 450.0°C
Accuracy with calibration ±0.5°C within ±50°C of the calibration point
Calibration method One-point calibration at an actual temperature within the measuring range
Operating environment 0 to 40°C; 15 to 80% RH, non-condensing
Communication RS-232C, 9600 bps
Analog output 10 mV/°C; 1 mV resolution

The instrument’s range does not extend the rating of a connected probe. Use the narrower applicable range and confirm the calibration conditions required for your measurement.

Fiber Optic Probe Selection

Each probe below is shown with its existing product picture. Model-code asterisks indicate ordering selections, such as cable length or coating length; confirm the complete code before ordering.

FS100-*M General-Purpose Probe

SpecificationFS100-*M

Anritsu FS100-*M general-purpose probe

Temperature range −190 to 260°C
Selection guidance General measurements involving microwaves or electromagnetic fields.
Repair classification Listed as repairable; assessment depends on the damage

FS150-*M Durable General-Purpose Probe

SpecificationFS150-*M

Anritsu FS150-*M durable general-purpose probe

Temperature range −190 to 260°C
Selection guidance A more robust tip arrangement with the sensing section the same thickness as the cable.
Repair classification Listed as repairable; assessment depends on the damage

FS100H-**-*M Liquid and Chemical-Resistant Probe

SpecificationFS100H-**-*M

Anritsu FS100H-**-*M liquid and chemical-resistant probe

Temperature range −190 to 260°C
Selection guidance For compatible oils, liquids and chemicals; select the required coating configuration.
Repair classification Listed as repairable; assessment depends on the damage

FS150H-**-*M Durable Liquid and Chemical-Resistant Probe

SpecificationFS150H-**-*M

Anritsu FS150H-**-*M durable liquid and chemical-resistant probe

Temperature range −190 to 260°C
Selection guidance Liquid and chemical-resistant construction with a more robust tip arrangement.
Repair classification Listed as repairable; assessment depends on the damage

FS200-*M Chemical-Resistant Probe

SpecificationFS200-*M

Anritsu FS200-*M chemical-resistant probe

Temperature range −30 to 200°C
Selection guidance For compatible chemicals; confirm the fluid and concentration before selection.
Repair classification Listed as repairable; assessment depends on the damage

FS300-*M Light-Resistant Probe

SpecificationFS300-*M

Anritsu FS300-*M light-resistant probe

Temperature range −190 to 260°C
Selection guidance For measurements exposed to intense light, including laser or plasma environments.
Repair classification Listed as repairable; assessment depends on the damage

FS400-*M High-Temperature Probe

SpecificationFS400-*M

Anritsu FS400-*M high-temperature probe

Temperature range −20 to 400°C
Selection guidance For high-temperature materials, including semiconductor applications; not for liquids.
Repair classification Listed as repairable; assessment depends on the damage

FS500-*M Needle Probe

SpecificationFS500-*M

Anritsu FS500-*M needle probe

Temperature range −60 to 260°C
Selection guidance For insertion into semisolid samples such as food.
Repair classification Listed as repairable; assessment depends on the damage

FS600-*M Plastic Probe

SpecificationFS600-*M

Anritsu FS600-*M plastic probe

Temperature range 0 to 80°C
Selection guidance For specialised research applications involving MRI, NMR or hyperthermia equipment; confirm the complete installation requirements.
Repair classification Not repairable

Extension Cables and Installation Accessories

Check the complete optical connection arrangement, routing and mechanical support before selecting extensions or fittings.

FK1-*M General-Purpose Extension Cable

Anritsu FK1-*M general-purpose extension cable

Extension cable for standard installations.

FK2-*M Heavy-Duty Extension Cable

Anritsu FK2-*M heavy-duty extension cable

Extension cable for more demanding installation environments.

FA1 Connection Adapter

Anritsu FA1 connection adapter

Connects a probe to an extension cable.

FN1-T Compression Fitting

Anritsu FN1-T compression fitting

NPT 1/8 fitting with TFE sealant material.

FN1-V Compression Fitting

Anritsu FN1-V compression fitting

NPT 1/8 fitting with Viton sealant material.

For a vacuum or pressure-vessel installation, confirm the rating of the complete probe-and-fitting assembly at the operating temperature. The published FN1 test uses a stainless steel rod and must not be treated as an unconditional pressure rating for every fiber probe installation.

PC Connection and Data Collection

The existing product documentation specifies AMS-850 software and RS-232C communication. The FL-2000 provides internal memory, whereas the FL-2400 requires an external data-collection arrangement when records are needed.

Confirm software, operating-system and connection compatibility before ordering. The existing page lists older Windows versions; it does not establish Windows 11 support.

FL Series Video

Choosing an FL Measurement System

  • Measurement points: decide whether one or four channels are required.
  • Environment: describe the microwave, electrical, magnetic or light exposure.
  • Probe contact: specify the surface, liquid or sample, including chemical composition where relevant.
  • Installation: provide cable length, routing, mounting and any vessel-entry requirements.
  • Records and outputs: identify whether you need PC data collection or an analog signal.

Related Anritsu Instruments

Need Help Selecting an FL Thermometer?

Contact Seacom Process Instruments Sdn Bhd with your temperature range, number of channels, sample material and measurement environment. For an existing system, include the instrument and probe model numbers.