Vaisala viewLinc provides continuous monitoring, alarming and reporting for temperature, humidity, CO₂, differential pressure and other critical parameters in GxP-regulated and demanding industrial environments.
The Vaisala viewLinc Continuous Monitoring System is a complete environmental monitoring, alarming and reporting platform for pharmaceutical facilities, biotechnology production, cleanrooms, laboratories, warehouses, hospitals, blood banks, cold rooms, freezers and other critical environments.
At the centre of the system is viewLinc Enterprise Server 5.2, the current on-premises software platform. It receives measurements from Vaisala data loggers, transmitters and compatible Modbus devices, then provides real-time displays, multi-stage alarms, secure records, audit trails and automated reports.
viewLinc operates independently from process-control and building-management systems, preserving a separate monitoring record for quality and compliance. Validated data can also be made available to authorised external systems through optional OPC UA or the viewLinc API.
| System Layer | Function |
|---|---|
| Measurement Probes and Transmitters | Measure temperature, relative humidity, CO₂, differential pressure, dew point and other required parameters |
| Data Loggers | Record measurements independently and transfer data through Ethernet, PoE, Wi-Fi or VaiNet |
| Network and Access Devices | Provide secure communication between field devices and the monitoring server |
| viewLinc Enterprise Server | Stores records and manages monitored locations, alarms, events, reports and user access |
| Users and Alarm Recipients | Review dashboards and reports, acknowledge alarms and perform authorised system functions |
| External Systems | Receive authorised viewLinc data through optional OPC UA or API integration |
viewLinc is designed for regulated environments where monitoring records must remain complete, attributable, reviewable and protected from unauthorised change.
| Quality Requirement | viewLinc Capability |
|---|---|
| FDA 21 CFR Part 11 | Access controls, electronic records, audit trails and controlled system functions support compliant implementation |
| EU GMP Annex 11 | Validation documentation, security, audit trails, data retention and controlled access support regulated computerised systems |
| Data Integrity | Secure records, device memory, audit trails and role-based permissions help protect measurement history |
| Calibration Traceability | Compatible devices are available with calibration traceable to SI units through national metrology institutes or accredited laboratories |
| Validation | IQ/OQ protocols and optional GAMP-based GxP documentation support documented system implementation |
| Audit Readiness | Historical, alarm, event and audit-trail reports provide accessible evidence for quality review and inspections |
| Alarm Method | Typical Use |
|---|---|
| On-Screen Alarm | Immediate notification for users viewing the system |
| Detailed alarm information delivered to selected recipients | |
| SMS or Voice | Escalation to mobile or telephone recipients using configured services |
| Signal Tower | Visible and audible local indication in production, laboratory or warehouse areas |
| Relay Output | Activation of compatible beacons, diallers or external alarm systems |
| Escalation Schedule | Progressive notification when an alarm remains unacknowledged |
The Vaisala VDL200 is the current secure PoE data logger for temperature, humidity, CO₂, analog and Boolean monitoring. Probe combinations support rooms, refrigerators, freezers, incubators and other critical equipment.
The established Vaisala DL Series remains an important part of many viewLinc installations. These compact loggers provide autonomous recording at the measurement point and are available for temperature, humidity, thermocouple and universal-input applications.
DL Series devices are particularly relevant when expanding an existing viewLinc system, maintaining compatibility with an installed logger fleet or addressing a specialised measurement that requires a dedicated logger type.
Vaisala DL2000
Temperature and relative-humidity data logger for rooms, warehouses, laboratories, stability areas and controlled storage environments.
Vaisala DL1000 and DL1400 Series
High-accuracy temperature data loggers for refrigerators, freezers, cold rooms, incubators, chambers and other critical equipment.
Vaisala DL1700
Multi-channel thermocouple logger for wide-range temperature monitoring, validation, mapping and specialised process applications.
Vaisala DL4000
Universal-input logger for integrating compatible current or voltage transmitters and additional measurement parameters into viewLinc.
| Logger Series | Primary Measurement | Typical Applications | Product Link |
|---|---|---|---|
| DL2000 | Temperature and relative humidity | Rooms, laboratories, warehouses and controlled environmental spaces | View DL2000 |
| DL1000, DL1400, DL1016 and DL1416 | High-accuracy temperature | Refrigerators, freezers, cold rooms, incubators and chambers | View DL Temperature Loggers |
| DL1700 | Thermocouple temperature | Wide-range temperature, mapping, validation and specialised equipment | View DL1700 |
| DL4000 | Universal current or voltage input | Compatible pressure, level, flow, gas and other analog transmitters | View DL4000 |
| Requirement | Recommended Direction |
|---|---|
| Expansion of an existing DL installation | Review the installed logger models, probes, network interfaces and viewLinc compatibility before selecting an additional DL Series device |
| New PoE-based project | Consider VDL200 as the current flexible Power-over-Ethernet platform |
| Dedicated thermocouple measurement | DL1700 provides specialised multi-channel thermocouple monitoring |
| Existing universal-input architecture | DL4000 supports compatible analog transmitters in established systems |
| New analog or Boolean input requirement | Consider VDL200 with ANP115 or another supported input configuration |
The Vaisala RFL100 and AP10 use secure, long-range VaiNet wireless communication. Battery-powered loggers can continue recording during temporary network or power interruptions at the access-point level.
The Vaisala CAB100 centralises differential-pressure transmitters, analog input channels, intrinsic-safety barriers and selected interface equipment in a preconfigured cabinet.
The Vaisala PDT101 and PDT102 provide low differential-pressure measurement for cleanroom pressure cascades, isolation rooms, data centres and air-handling systems.
The Vaisala HMT370EX supports humidity, temperature and moisture measurement in hazardous areas through properly engineered intrinsic-safety interfaces.
| Monitoring Requirement | Recommended Component |
|---|---|
| Room temperature and humidity with PoE | VDL200 with a compatible Vaisala humidity and temperature probe |
| Wireless room monitoring | RFL100 with HMP115 or compatible probe and AP10 access point |
| Refrigerator or cold-room temperature | VDL200 or RFL100 with an external temperature probe |
| Ultra-low freezer | Compatible logger with TMP115 wide-range temperature probe |
| Liquid-nitrogen storage | Compatible logger and cryogenic TMP115 configuration |
| CO₂ incubator | VDL200 or compatible logger with GMP251 and required temperature/humidity probes |
| Existing DL temperature/RH installation | DL2000 or the appropriate DL1000/DL1400 temperature logger according to the existing architecture |
| Multi-channel thermocouple monitoring | DL1700 thermocouple data logger |
| Established universal analog inputs | DL4000 universal-input data logger |
| Cleanroom differential pressure | PDT101 or PDT102 integrated through CAB100 or a compatible input device |
| Remote analog transmitter | ANP115 with VDL200 or an appropriate CAB100 analog-input configuration |
| Hazardous-area humidity | HMT370EX with certified barriers and a suitable CAB100/viewLinc architecture |
| Interruption | System Response |
|---|---|
| Temporary Device Communication Loss | Compatible data loggers continue recording measurements in local memory |
| Communication Restored | Stored records are transferred automatically to close the data gap |
| Server Interruption | Monitoring devices continue autonomous recording according to their local memory capacity |
| Ethernet Switch Power Loss | Battery-backed compatible loggers continue recording even when network communication is unavailable |
| Wireless Interruption | RFL100 retains measurements locally until the VaiNet connection returns |
| Integration Method | Purpose |
|---|---|
| Modbus Devices | Bring compatible third-party measurement parameters into viewLinc for monitoring |
| Vaisala OPC UA Server | Provide authorised viewLinc data to OPC UA-compatible historians, MES or other systems |
| viewLinc API | Enable custom extraction of real-time data, historical records, alarms and events |
| Active Directory | Synchronise applicable users and groups for enterprise user management |
OPC UA and API integrations extract data from viewLinc. They do not import or overwrite validated monitoring records in viewLinc.
| Project Stage | Support Scope |
|---|---|
| Requirement Review | URS, monitored parameters, operating ranges, alarm strategy and compliance objectives |
| Monitoring-Point Selection | Rooms, equipment, storage locations, pressure boundaries and sensor placement |
| System Architecture | Server, database, network, VaiNet coverage, PoE, cabinets and device quantities |
| Installation | Data loggers, probes, access points, cabinets, pressure tubing and network components |
| Commissioning | Device configuration, locations, thresholds, alarm notifications, reports and functional testing |
| Validation | IQ/OQ execution and project documentation according to the agreed validation scope |
| Calibration | Initial and lifecycle calibration planning with suitable traceability |
| Lifecycle Support | Training, system review, expansion, software updates and service planning |
| Project Requirement | Recommended Approach |
|---|---|
| Small PoE monitoring system | VDL200 loggers connected through the existing Ethernet and PoE network |
| Wireless warehouse or laboratory | RFL100 loggers with AP10 access points following a VaiNet site assessment |
| Cleanroom pressure monitoring | PDT101/PDT102 transmitters with a suitable CAB100 or analog-input configuration |
| Mixed wired and wireless facility | Combine VDL200, RFL100/AP10 and appropriate interface devices in one viewLinc server |
| Hazardous-area measurement | Certified HMT370EX and intrinsic-safety interfaces integrated through a suitable safe-area architecture |
| Multiple sites | Central viewLinc Enterprise Server with network and access design reviewed for each facility |
| Quality-system integration | Optional OPC UA or API after defining authorised consumers, data scope and cybersecurity requirements |
Seacom Process Instruments supplies, installs and supports the Vaisala viewLinc Continuous Monitoring System in Malaysia for pharmaceutical facilities, cleanrooms, laboratories, hospitals, warehouses, cold-chain storage, semiconductor manufacturing and other critical environments.
Our team can assist with system design, monitoring-point selection, wireless coverage assessment, server and network architecture, installation, commissioning, alarm configuration, reporting, calibration and GxP validation documentation.
Contact Seacom with your facility layout, monitored parameters, temperature ranges, alarm requirements, device quantities, network constraints and validation expectations for a suitable viewLinc configuration.