Select a Dew Point Transmitter by Application
Refrigerated dryers:Vaisala DMT132 for dryer-outlet dew point measurement with a two-wire 4–20 mA signal.
Compact dryers and OEM equipment:Vaisala DMT143 and DMT143L for installations needing a compact transmitter, with configuration selected for the required range and output.
Ultra-dry air and suitable industrial gases:Vaisala DMT153 for applications requiring calibrated dew/frost point measurement down to −80 °C Td/f.
Pressurised pipelines:Vaisala DMP8 with an adjustable insertion arrangement and process fittings selected for the line.
Tight installation spaces:Vaisala DMP7 for a compact probe installation.
Dry rooms:Vaisala DMP1 for wall-mounted measurement in low-humidity environments.
Hot industrial drying processes: review Vaisala DMP5 or DMP6 against the actual gas temperature and installation requirements.
Match the Sensor and Output to Your System
Confirm the operating dew point and required accuracy before comparing models. A refrigerated dryer and an ultra-dry gas process need different measurement performance. Also specify gas composition, pressure, temperature and whether the sensor will be fitted directly into the process or installed in a sampling arrangement.
The probe, transmitter and display are not always one device. Where a selected probe needs an additional transmitter for the required display or output, include that equipment in the selection. State whether your receiving system needs 4–20 mA, a voltage signal, Modbus or another interface so the complete configuration can be checked.
Replacing an Existing Dew Point Transmitter?
Send the existing model and order code, a photograph of its label, the output settings and the process connection. A replacement should be checked against the installation as well as the required measurement range.
For an existing DMT152, review the DMT153 configuration. For other older instruments listed in this category, use their product pages to identify the replacement direction and confirm the details with Seacom before ordering.
Dew Point Measurement Guides
Choosing a dew point instrument depends on whether you need permanent monitoring or portable checking, the dryer or process type, operating pressure and the target dew point. Use the comparison below as a starting point before selecting the instrument.
Application
Portable or Fixed
Pressure / Installation
Target Dew Point
Recommended Instrument
Refrigerated air dryer
Fixed
Dryer outlet; up to 20 bar depending on installation
A permanent transmitter is normally preferred when the process needs continuous measurement, alarms, control-system integration or long-term trending. Portable measurement is more suitable for maintenance, commissioning, troubleshooting and checking several measurement points with one instrument.
Requirement
Recommended Approach
Continuous dryer monitoring
Fixed dew point transmitter
Permanent alarm or PLC/BMS signal
Fixed dew point transmitter
Check several dryers or air lines
Portable dew point meter
Verify an installed transmitter
Portable reference instrument
Commissioning or troubleshooting
Portable measurement, followed by permanent monitoring where required
The Vaisala DPT145 provides online dew-point, pressure and temperature measurement for SF6-insulated electrical equipment. The model is being discontinued and should not be specified for new projects.
Measures dew point, pressure and temperature
Calculates SF6 density, normalised pressure and moisture in ppm
RS-485 communication with Modbus RTU
Contact Seacom for availability and replacement assessment
The Vaisala DPT146 combines dew-point and process-pressure measurement in one compact transmitter for compressed-air systems. This model is discontinued and should not be selected for new projects.
Dew-point measurement from −70 to +30 °C Td
Absolute-pressure measurement from 1 to 12 bar
Pressure-compensated dew point and ppm calculation
Analog outputs and RS-485 with Modbus RTU
Contact Seacom for existing-unit support and replacement assessment
The Vaisala DMT143 and DMT143L provide compact, dependable dew-point measurement for small industrial dryers, compressed-air systems, glove boxes and OEM equipment.
Dew-point measurement range across the family from −70 to +60 °C Td/f
Accuracy up to ±2 °C Td/f
Vaisala DRYCAP® technology with automatic calibration
Resistant to condensation, compressor oil and particulate contamination
Analog output and RS-485 with Modbus RTU options
Compatible with the Vaisala Indigo80 handheld indicator
The Vaisala DMT152 provides accurate dew-point measurement down to −80 °C Td/f for ultra-dry industrial and OEM applications. This model is discontinued and has been replaced by the Vaisala DMT153.
Calibrated dew-point range from −80 to −20 °C Td/f
Accuracy up to ±2 °C Td/f
Operating pressure up to 50 bar
Analog outputs and RS-485 communication
DRYCAP® sensor resistant to condensation and contamination
The Vaisala DMT132 is a compact and economical dew-point transmitter designed to verify refrigerant-dryer performance by measuring the actual outlet-air dew point.
Dew-point measurement range from −30 to +50 °C Td/f
Accuracy up to ±1 °C in the typical refrigerant-dryer range
The Vaisala DMT345 and DMT346 provided direct dew-point measurement in hot industrial drying processes. Both models are discontinued and replaced by Vaisala DMP5 or DMP6 smart probes with an Indigo transmitter.
DMT345: former solution for processes up to +180 °C
DMT346: former solution for very hot processes up to +350 °C
DMT345 replacement: DMP5 with a suitable Indigo transmitter
DMT346 replacement: DMP6 with a suitable Indigo transmitter
Direct in-process measurement without a conventional sampling system
Contact Seacom for mechanical and electrical migration review
The Vaisala DMT340 Series provided configurable dew-point and temperature measurement for industrial low-humidity applications. The series is discontinued and replaced by Vaisala Indigo500 transmitters with DMP7 or DMP8 smart probes.
Former models: DMT341, DMT342, DMT344, DMT347 and DMT348
Designed for dry rooms, industrial dryers, compressed air and process gases
Legacy display, data logging, analog, relay and communication options
Use DMP7 for compact, wall-mounted or tight-space applications
Use DMP8 for pressurised processes and pipelines
Pair the selected probe with an Indigo500 transmitter
The Vaisala Indigo500 Series provides flagship industrial measurement integration: choose Indigo510 for a simplified single-probe system or Indigo520 for full dual-probe capability.
Indigo510: one probe and two isolated analog outputs
Indigo520: two probes, four isolated outputs and two relays
Ethernet web interface and Modbus TCP communication
The Vaisala Indigo200 Series is the standard transmitter platform for one interchangeable Indigo-compatible smart probe, providing local display and practical automation-system connectivity.
Indigo201 with three analog outputs and two relays
Indigo202 with Modbus RTU and two relays
Colour display with numerical and graphical views
IP65 enclosure for industrial measurement applications
The Vaisala DRYCAP® Dew Point and Temperature Probe DMP5 measures humidity directly in hot industrial processes with a long stainless-steel probe and adjustable installation depth.
Direct in-line measurement at process temperatures up to +180 °C
Dew point measurement range from −40 to +100 °C Td/f
Long probe reaches through insulation and thick process walls
Built-in Modbus RTU or integration with Vaisala Indigo transmitters
Connect to Indigo80 for portable display, diagnostics, configuration and field calibration
The Vaisala DRYCAP® Dew Point and Temperature Probe DMP8 provides reliable low-humidity measurement in pressurised pipelines with adjustable installation depth.
Dew point measurement range from −70 to +80 °C Td/f
Designed for pressurised processes from 0 to 40 bar absolute
Adjustable insertion depth with ISO R 1/2 or NPT 1/2 process connection
Optional ball-valve kit permits insertion and removal without shutting down the process
Use with Modbus RTU, an Indigo transmitter or the portable Indigo80 handheld indicator
This website uses cookies to ensure you get the best experience on our website