Cart
Custom content

This is custom content

  • Out-of-Stock
    Vaisala DMT152 - Discontinued

Vaisala DMT152 Dew Point Transmitter – Discontinued

The Vaisala DMT152 provides accurate dew-point measurement down to −80 °C Td/f for ultra-dry industrial and OEM applications. This model is discontinued and has been replaced by the Vaisala DMT153.

  • Calibrated dew-point range from −80 to −20 °C Td/f
  • Accuracy up to ±2 °C Td/f
  • Operating pressure up to 50 bar
  • Analog outputs and RS-485 communication
  • DRYCAP® sensor resistant to condensation and contamination
  • Use DMT153 for new projects

Need advice or a quotation?

Ask Seacom about specifications, availability and the right instrument for your application.

Product status: Vaisala is discontinuing the DMT152 and states that it should not be specified for new projects. The Vaisala DMT153 is the official successor, retaining the same core measurement range and DRYCAP® 180U sensor while adding current connectivity and service tools.

Vaisala DMT152 for Existing Ultra-Dry Applications

The Vaisala DRYCAP® DMT152 was developed for very-low-dew-point measurement in semiconductor and battery manufacturing, plastics and compressed-air dryers, glove boxes, dry chambers, pure-gas systems, additive manufacturing and other moisture-sensitive processes.

Its compact stainless-steel construction supports direct process installation or use with a sampling cell. The sensor tolerates temporary condensation and provides stable performance in demanding combinations of low humidity and elevated gas temperature.

DMT152 Measurement Performance

SpecificationDMT152 performance
Sensor Vaisala DRYCAP® 180U
Calibrated dew/frost-point range −80 to −20 °C Td/f
Non-calibrated output range −100 to +20 °C Td/f
Accuracy from −80 to −40 °C Td/f ±2 °C Td/f
Accuracy from −40 to −20 °C Td/f ±3 °C Td/f
Typical dry-to-wet response 2 seconds to 63%; 5 seconds to 90%
Typical wet-to-dry response 30 seconds to 63%; 7.5 minutes to 90%
Typical long-term stability Better than 2 °C Td/f per year
Recommended calibration interval Two years under normal conditions

Legacy Outputs and Installation

FeatureDMT152 configuration
Analog outputs Configurable current or voltage outputs, depending on ordered model
Digital communication RS-485
Operating pressure Up to 50 bar with the correct supply and installation
Process connections G1/2, NPT 1/2 and selected UNF options
Electrical connections Two four-pin M8 connectors
Handheld compatibility Vaisala MI70 platform
Protection rating IP66
Wetted housing material AISI 316L stainless steel

Replacing DMT152 with DMT153

The DMT153 is designed to provide familiar DMT152 measurement performance while updating the electrical connection, digital protocol, portable tools and transmitter-platform compatibility. It is the correct starting point for new specifications and most DMT152 migration projects.

Migration pointDMT152DMT153
Product status Discontinued Current official successor
Calibrated range −80 to −20 °C Td/f −80 to −20 °C Td/f
Accuracy ±2 °C from −80 to −40 °C; ±3 °C from −40 to −20 °C Same core accuracy
Sensor and algorithm DRYCAP® 180U DRYCAP® 180U with the same core algorithm
Analog signals Current or voltage options One current and one voltage channel in analog mode
Digital communication RS-485 Modbus RTU over RS-485
Operating mode Configuration-dependent legacy arrangement Standalone analog mode or digital mode; not simultaneous
Electrical connector Two M8 four-pin connectors One M12 five-pin connector
Portable indicator MI70 Indigo80; not backward compatible with MI70
Transmitter platform Not Indigo compatible Compatible with Vaisala Indigo transmitters
Configuration software Legacy service tools Vaisala Insight PC software
Process threads Included a 5/8-18 UNF option G1/2, NPT 1/2 or UNF 3/4-16

Not a direct wiring swap: DMT153 replaces the DMT152 functionally, but its M12 connector, wiring, output-mode logic, available process threads and handheld platform differ. Check the complete installed DMT152 order code and receiving system before ordering a replacement.

Explore the Vaisala DMT153 replacement

Information Needed for a DMT152 Replacement

  • Complete DMT152 order code and serial number
  • Required dew-point or ppm measurement range
  • Gas type, operating pressure and gas temperature
  • Existing process connection or sampling cell
  • Analog signal type, scaling and receiving-system input
  • RS-485 use and existing communication settings
  • Power supply, cable arrangement and connector access
  • Portable indicator, calibration and data-logging requirements

Direct Installation and Sampling Systems

DMT152 installations may measure directly at process pressure or through a sampling cell. Retaining the same measurement location does not automatically guarantee the same performance after replacement: check leaks, tubing material, sample flow, pressure reduction, isolation method and the time required for the system to reach equilibrium.

Ultra-dry measurements are particularly sensitive to ambient-air ingress and moisture released from sampling tubes. Use clean stainless-steel tubing, minimise joints and dead volumes, and locate the measurement point as close to the process as practical.

Existing DMT152 Maintenance

For an operating DMT152, retain its manuals, calibration records, order code, output scaling and wiring documentation. Continued service, calibration and remaining product availability should be checked for the individual unit and application.

Do not change a working installation solely because the product has entered discontinuation. Plan the migration according to maintenance risk, spare availability, calibration schedule, shutdown access and the importance of the measurement to production.

Vaisala DMT152 Support and DMT153 Migration in Malaysia

Seacom Process Instruments supports existing Vaisala DMT152 installations in Malaysia and supplies the current Vaisala DMT153 replacement for battery production, semiconductor manufacturing, pure-gas systems, compressed air, plastics drying, glove boxes and other ultra-dry applications.

Our team can assist with product-status checks, order-code review, output and wiring comparison, process connections, sampling cells, Indigo integration, Indigo80 portable use and calibration planning.

Contact Seacom with the existing DMT152 model code, process conditions, required outputs, connection details and receiving-system configuration so we can assess a suitable DMT153 migration arrangement.

Product documents

Catalogues, manuals and other files available for this instrument.

DMT152 catalogue

Dew Point Transmitter for Very Dry Environment DMT152

562.89KB
Download

You might also like

Vaisala DMT132 Dew Point Transmitter | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DMT132 is a compact and economical dew-point transmitter designed to verify refrigerant-dryer performance by measuring the actual outlet-air dew point.

  • Dew-point measurement range from −30 to +50 °C Td/f
  • Accuracy up to ±1 °C in the typical refrigerant-dryer range
  • Two-wire, loop-powered 4–20 mA output
  • Operating pressure up to 20 bar
  • Resistant to condensation and compressor oil
  • Optional warning LED and loop-powered display
Vaisala DMT143 & DMT143L Dew Point Transmitters | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DMT143 and DMT143L provide compact, dependable dew-point measurement for small industrial dryers, compressed-air systems, glove boxes and OEM equipment.

  • Dew-point measurement range across the family from −70 to +60 °C Td/f
  • Accuracy up to ±2 °C Td/f
  • Vaisala DRYCAP® technology with automatic calibration
  • Resistant to condensation, compressor oil and particulate contamination
  • Analog output and RS-485 with Modbus RTU options
  • Compatible with the Vaisala Indigo80 handheld indicator

15 other products in the same category:

Vaisala Transmitter Indigo300
  • Out-of-Stock

The Vaisala Indigo300 is a rugged industrial transmitter for one Vaisala Indigo-compatible smart probe, providing local measurement display and up to three configurable analog outputs.

Its corrosion-resistant IP66 metal enclosure, flexible probe mounting and interchangeable probe design make Indigo300 suitable for humidity, temperature, dew point, CO2, moisture in oil and other demanding industrial measurements.

Vaisala DMT153 Dew Point Transmitter
  • Out-of-Stock

The Vaisala DMT153 provides traceable low-dew-point measurement for ultra-dry industrial processes. It is the current replacement for the DMT152, with modern analog, Modbus and Vaisala Indigo connectivity.

  • Calibrated dew-point range from −80 to −20 °C Td/f
  • Dew-point accuracy up to ±2 °C Td/f
  • Operating pressure from vacuum to 50 bar absolute
  • Analog outputs or RS-485 with Modbus RTU
  • Compatible with Vaisala Indigo transmitters and Indigo80
  • DRYCAP® sensor with automatic calibration and sensor purge
Indigo200 Series Transmitters for Vaisala smart probes for Vaisala Smart Probes
  • Out-of-Stock

The Vaisala Indigo200 Series is the standard transmitter platform for one interchangeable Indigo-compatible smart probe, providing local display and practical automation-system connectivity.

  • Indigo201 with three analog outputs and two relays
  • Indigo202 with Modbus RTU and two relays
  • Colour display with numerical and graphical views
  • IP65 enclosure for industrial measurement applications
Vaisala DPT146 Dew Point Transmitter - Discontinued
  • Out-of-Stock

The Vaisala DPT146 combines dew-point and process-pressure measurement in one compact transmitter for compressed-air systems. This model is discontinued and should not be selected for new projects.

  • Dew-point measurement from −70 to +30 °C Td
  • Absolute-pressure measurement from 1 to 12 bar
  • Pressure-compensated dew point and ppm calculation
  • Analog outputs and RS-485 with Modbus RTU
  • Contact Seacom for existing-unit support and replacement assessment
Vaisala Indigo510 Indigo520 Malaysia
  • Out-of-Stock

The Vaisala Indigo500 Series provides flagship industrial measurement integration: choose Indigo510 for a simplified single-probe system or Indigo520 for full dual-probe capability.

  • Indigo510: one probe and two isolated analog outputs
  • Indigo520: two probes, four isolated outputs and two relays
  • Ethernet web interface and Modbus TCP communication
  • Rugged IP66 and NEMA 4 metal enclosure
Vaisala DMP6 High-Temperature Dew Point Probe | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DRYCAP® Dew Point Probe DMP6 measures humidity directly inside very hot industrial processes using a robust probe and passive cooling set.

  • Direct in-line measurement at process temperatures from +100 to +350 °C
  • Dew point measurement range from −25 to +100 °C Td/f
  • Passive cooling requires no power, cooling water or moving components
  • Built-in Modbus RTU or integration with Vaisala Indigo transmitters
  • Connect to Indigo80 for portable display, diagnostics, configuration and field calibration
Dew Point Probe DMP8
  • Out-of-Stock

The Vaisala DRYCAP® Dew Point and Temperature Probe DMP8 provides reliable low-humidity measurement in pressurised pipelines with adjustable installation depth.

  • Dew point measurement range from −70 to +80 °C Td/f
  • Designed for pressurised processes from 0 to 40 bar absolute
  • Adjustable insertion depth with ISO R 1/2 or NPT 1/2 process connection
  • Optional ball-valve kit permits insertion and removal without shutting down the process
  • Use with Modbus RTU, an Indigo transmitter or the portable Indigo80 handheld indicator
Vaisala DMT345 DMT346 Dewpoint Transmitter - Discontinued
  • Out-of-Stock

The Vaisala DMT345 and DMT346 provided direct dew-point measurement in hot industrial drying processes. Both models are discontinued and replaced by Vaisala DMP5 or DMP6 smart probes with an Indigo transmitter.

  • DMT345: former solution for processes up to +180 °C
  • DMT346: former solution for very hot processes up to +350 °C
  • DMT345 replacement: DMP5 with a suitable Indigo transmitter
  • DMT346 replacement: DMP6 with a suitable Indigo transmitter
  • Direct in-process measurement without a conventional sampling system
  • Contact Seacom for mechanical and electrical migration review
Vaisala DMT132 Dew Point Transmitter | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DMT132 is a compact and economical dew-point transmitter designed to verify refrigerant-dryer performance by measuring the actual outlet-air dew point.

  • Dew-point measurement range from −30 to +50 °C Td/f
  • Accuracy up to ±1 °C in the typical refrigerant-dryer range
  • Two-wire, loop-powered 4–20 mA output
  • Operating pressure up to 20 bar
  • Resistant to condensation and compressor oil
  • Optional warning LED and loop-powered display
Vaisala DMT340 Dewpoint Transmitter | Replaced by Indigo500 and DMP
  • Out-of-Stock

The Vaisala DMT340 Series provided configurable dew-point and temperature measurement for industrial low-humidity applications. The series is discontinued and replaced by Vaisala Indigo500 transmitters with DMP7 or DMP8 smart probes.

  • Former models: DMT341, DMT342, DMT344, DMT347 and DMT348
  • Designed for dry rooms, industrial dryers, compressed air and process gases
  • Legacy display, data logging, analog, relay and communication options
  • Use DMP7 for compact, wall-mounted or tight-space applications
  • Use DMP8 for pressurised processes and pipelines
  • Pair the selected probe with an Indigo500 transmitter
Vaisala DMP5 High-Temperature Dew Point Probe | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DRYCAP® Dew Point and Temperature Probe DMP5 measures humidity directly in hot industrial processes with a long stainless-steel probe and adjustable installation depth.

  • Direct in-line measurement at process temperatures up to +180 °C
  • Dew point measurement range from −40 to +100 °C Td/f
  • Long probe reaches through insulation and thick process walls
  • Built-in Modbus RTU or integration with Vaisala Indigo transmitters
  • Connect to Indigo80 for portable display, diagnostics, configuration and field calibration
Vaisala DMT143 & DMT143L Dew Point Transmitters | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DMT143 and DMT143L provide compact, dependable dew-point measurement for small industrial dryers, compressed-air systems, glove boxes and OEM equipment.

  • Dew-point measurement range across the family from −70 to +60 °C Td/f
  • Accuracy up to ±2 °C Td/f
  • Vaisala DRYCAP® technology with automatic calibration
  • Resistant to condensation, compressor oil and particulate contamination
  • Analog output and RS-485 with Modbus RTU options
  • Compatible with the Vaisala Indigo80 handheld indicator
Smart Dew Point Probe and Transmitter DMP7
  • Out-of-Stock

The Vaisala DRYCAP® Dew Point and Temperature Probe DMP7 is designed for accurate low-humidity measurement where installation space is limited.

  • Short 41 mm probe for remote installation in tight spaces
  • Dew point measurement range from −70 to +80 °C Td/f
  • Pressure-tight installation for processes from 0 to 10 bar
  • Use with Modbus RTU, an Indigo transmitter or the portable Indigo80 handheld indicator
  • Suitable for dry rooms, compressed air, industrial drying and semiconductor equipment
Vaisala Dewpoint Probe DMP1
  • Out-of-Stock

The Vaisala DMP1 Dew Point and Temperature Probe provides fast, dependable low-humidity measurement for dry rooms and moisture-sensitive manufacturing areas.

  • Dew point measurement range from −70 to +80 °C Td/f
  • Fast response for detecting changes across large dry rooms
  • Modbus RTU communication or integration with Vaisala Indigo transmitters
  • Connect to Indigo80 for portable display, data logging, diagnostics and field calibration
  • Suitable for battery production, semiconductor manufacturing and controlled dry environments
Vaisala DPT145 SF6 Transmitter | Discontinued
  • Out-of-Stock

The Vaisala DPT145 provides online dew-point, pressure and temperature measurement for SF6-insulated electrical equipment. The model is being discontinued and should not be specified for new projects.

  • Measures dew point, pressure and temperature
  • Calculates SF6 density, normalised pressure and moisture in ppm
  • RS-485 communication with Modbus RTU
  • Contact Seacom for availability and replacement assessment
This website uses cookies to ensure you get the best experience on our website