Home

There are 10 products.

Showing 1-10 of 10 item(s)

Active filters

  • Categories: Flow
  • Categories: Others
  • Brand: Onicon
  • Brand: Others
  • Brand: Vaisala
Cabinet for Continuous Monitoring System (CMS)
Vaisala

Cabinet CAB100 for Continuous Monitoring System (CMS)

Vaisala CMS Industrial Cabinet CAB100 integrates Vaisala’s world-class instruments for monitoring differential pressure and other parameters into a simple, preconfigured instrument panel. In combination with the Vaisala viewLinc Enterprise Server Software, the cabinet provides pre-installed real-time monitoring of your critical environments.

Onicon

Electromagnetic Flowmeter FT-3000

ONICON's FT-3000 Series family of Inline Electromagnetic Flow Meters are suitable for measuring electrically conductive liquids in a wide variety of commercial HVAC applications. The FT-3000 series provides analog and digital outputs for flow rate and programmable pulse outputs for flow totalization and/or alarms.

The ONICON FT-3000 Inline Electromagnetic Flow Meters are available in various sizes and arrive factory-configured for ease of installation and start-up. All FT-3000 series flow meters are wet calibrated in a flow laboratory against standards that are directly traceable to international standards. A certificate of calibration accompanies every meter. Typical applications include monitoring of cooling water, heating water, condenser water and domestic water.

  • Highly Accurate
    Individually wet-calibrated with flow measurement accuracy from 0.2% to 0.4% of reading, depending on the transmitter type.

  • Simple Installation and Commissioning
    Each meter is factory programmed and ready for use upon delivery.

  • Low Maintenance
    No moving parts and durable construction provide years of maintenance-free service.

  • Simplified Installation and Commissioning
    Each meter is fully configured and programmed before it leaves the factory and is ready for use upon delivery.
Others

Leak Detector LD400

If gases escape through leaks in piping systems (e.g. untight screwed connections, corrosions and so on) ultrasonic noises are generated. By means of LD 400 even the smallest leakages which cannot be heard by the human ear can be detected even from distances of several meters. LD 400 transforms the inaudible signals into a frequency which can be identified. By means of the comfortable sound-proof headset these noises can be realized even in extremely noisy environments.

Due to a particularly designed acoustic trumpet a better focusing of the acoustic waves is achieved. This acoustic trumpet acts like a directional microphone while interfering ambient noises are cushioned and the accurate localization of the leakages is eased even in areas which are difficult to access.

SPI Magnetic Flowmeter MM800
Others

SPI Magnetic Flowmeter

Electromagnetic flow meters detect flow by using Faraday's Law of induction.

Inside an electromagnetic flow meter, there is an electromagnetic coil that generates a magnetic field, and electrodes that capture electromotive force(voltage). Due to this, although it may appear as if there is nothing inside the flow pipe of an electromagnetic flow meter, flow can be measured.

SPI Positive Displacement Flowmeter MG Series
Others

SPI Oval Gear Flowmeter

Oval gear flowmeters are categorised as positive displacement flow technology. When liquid flows through this type of positive displacement flowmeter, two oval geared rotors measure a constant volume per rotation within a precisely machined measuring chamber.

With each rotation, a constant volume of liquid is measured. The rotation of the oval gears is sensed via magnets embedded within the rotors. These magnets transmit a high resolution pulse output. The output signal can be process externally via a remote display controller or PLC or via a variety of output/display options available as accessories attached to the flowmeters.

The positive displacement flow technology allows for precise flow measurement of most clean liquids regardless of the media conductivity. Other liquid properties also have a minimal effect on the performance of this type of meter. Flow profile conditioning is not required as with alternative flow technology options making oval gear installations simple to install in tight spaces and at an economical price.

Others

Temperature And Universal Controller

Yashima's temperature controller and transmitter accepts 15 type of different input from thermocouple, R.T.D. mA & DC voltage. Range setting & alternation can be easy done from thermocouple to R. T. D. or mA to DC voltage. It has programmable scale range and it is so easy that you may program it within few touches!

Others

Ultrasonic Leak Detector

Whisper Ultrasonic Leak Detector is ideal for detecting and locating sources of ultrasonic sound through the use of sophisticated electronic circuitry. Unaffected by audible noise, Whisper incorporates an Internal Noise Control allowing for use in extremely noisy environments, such as mechanical rooms, and around operating chillers. Because Whisper is designed to detect ultrasound at 40.5 kHz, not even a murmur will escape detection.

Vaisala

Wi-Fi Data Logger HMT140 (for GxP Compliant Continuous Monitoring System CMS viewLinc)

The Vaisala HMT140 wireless data logger is designed for humidity, temperature and analog signal monitoring in warehouses, freezer and cryogenic farms, laboratories, blood banks and many other life science applications

The Vaisala HMT140 incorporates Vaisala HUMICAP® technology to measure relative humidity and temperature accurately and reliably. The Vaisala HUMICAP sensor is resistant to dust and most chemicals. Alternatively, the Vaisala HMT140 can connect to Resistance Temperature Detectors (RTDs), Voltage, Current and Contact sensors, making the Vaisala HMT140 the most versatile Vaisala data logger for life science applications.

back to top