Seacom supplies pressure data loggers, pressure chart recorders, low differential-pressure transmitters, barometers and barometric-pressure transfer standards for industrial, laboratory, cleanroom, HVAC, meteorological and environmental applications.
The correct pressure instrument depends on whether the application measures gauge pressure, differential pressure or atmospheric pressure. Selection must also consider the required range, accuracy, process connection, recording method, output signal, environmental protection and calibration requirements.
Pressure Measurement Solutions Available
Electronic pressure data loggers: Record line or equipment pressure for troubleshooting, surveys and unattended monitoring without a permanently connected computer.
Pressure chart recorders: Produce a continuous paper record that can be reviewed directly at the measurement location.
Differential-pressure transmitters: Monitor small pressure differences in cleanrooms, isolation rooms, data centres and air-handling systems.
Industrial digital barometers: Provide accurate atmospheric-pressure measurement, configurable outputs and long-term stability.
Compact barometric transmitters: Supply low-power pressure signals to weather stations, data loggers and environmental monitoring systems.
Pressure transfer standards: Support accurate field and laboratory comparison of barometric-pressure instruments.
Mechanical barometers: Provide straightforward local atmospheric-pressure indication without a permanently wired power supply.
Barographs: Create a visible paper-chart history of atmospheric-pressure changes over time.
Pressure Instrument Selection by Application
Application
Recommended product
Why it fits
Electronic recording of air, water or compatible equipment pressure
Records atmospheric pressure on a chart with selectable 1-day, 7-day or 32-day rotation periods.
Understand the Type of Pressure Required
Gauge pressure: Pressure measured relative to the surrounding atmospheric pressure, commonly used for compressed-air, water and hydraulic systems.
Differential pressure: The difference between two pressure points, used for room-pressure cascades, filters and airflow-related applications.
Atmospheric pressure: Absolute pressure of the surrounding atmosphere, measured by barometers for meteorology, environmental monitoring and reference work.
Absolute pressure: Pressure measured relative to a vacuum reference. Confirm this requirement explicitly because it is not interchangeable with gauge pressure.
Information Required for Pressure Instrument Selection
Pressure type: State whether the requirement is gauge, differential, atmospheric or absolute pressure.
Normal and maximum pressure: Provide the usual operating value, full required range and any possible startup or transient pressure peaks.
Process medium: Identify the gas or liquid and confirm compatibility with the sensor, process connection and wetted materials.
Accuracy requirement: Define the acceptable uncertainty at the actual operating pressure, not only as a percentage of full scale.
Pressure connection: Confirm the thread type, size, adaptor requirement, tubing arrangement and available installation space.
Temperature conditions: Provide the process and ambient temperature ranges at the installation location.
Recording method: Choose local indication, electronic data logging, paper chart, continuous transmitter output or network monitoring.
Output signal: Specify voltage, current, frequency, relay, serial communication or integration with a monitoring system.
Environmental protection: Consider indoor or outdoor installation, moisture, dust, washdown, vibration and enclosure rating.
Calibration: State the required calibration points, certificate type, tolerance and recalibration interval.
Common Pressure Measurement Applications
Compressed-air systems: Record pressure variation, compressor cycling and pressure loss during changes in plant demand.
Water and pump systems: Monitor pump operation, pressure decay, supply variation and intermittent pressure events.
Industrial equipment: Investigate pressure cycles, regulator behaviour and equipment performance during operation.
Cleanrooms and healthcare: Monitor low differential-pressure relationships between rooms and controlled areas.
Data centres and HVAC: Measure room, duct, filter and air-handling differential pressure.
Meteorology and environmental monitoring: Measure atmospheric pressure for weather stations, research and environmental data systems.
Laboratory and calibration work: Compare barometers and verify pressure instruments against a suitable reference.
Need Help Selecting a Pressure Instrument?
Contact Seacom with the pressure type, medium, normal and maximum range, process connection, temperature, required accuracy, recording method, output signal and calibration requirements. Our team can recommend a suitable pressure logger, chart recorder, differential-pressure transmitter or barometric-pressure instrument.
The Vaisala DPT146 combines dew-point and process-pressure measurement in one compact transmitter for compressed-air systems. This model is discontinued and should not be selected for new projects.
Dew-point measurement from −70 to +30 °C Td
Absolute-pressure measurement from 1 to 12 bar
Pressure-compensated dew point and ppm calculation
Analog outputs and RS-485 with Modbus RTU
Contact Seacom for existing-unit support and replacement assessment
The Dickson PR125, PR325 and PR525 are rugged battery-powered pressure data loggers for recording equipment and line pressure without a permanently connected computer.
PR125: 0 to 100 PSI pressure range
PR325: 0 to 300 PSI pressure range
PR525: 0 to 500 PSI pressure range
Pressure accuracy of ±1% of full scale
User-selectable sampling from 1 second to 24 hours
Segmented LCD with current and minimum/maximum readings
The Dickson PW4 and PW8 provide a continuous paper record of pressure at the measurement point for equipment monitoring, testing, troubleshooting and permanent visual documentation.
PW4 compact recorder with a 4-inch circular chart
PW8 high-resolution recorder with an 8-inch circular chart
Pressure ranges from 0–100 PSI up to 0–1000 PSI
24-hour or 7-day recording configurations
Pressure accuracy of ±2% of full scale
IP66/NEMA 4X weather-resistant enclosure
1/4-inch NPT process connection
Operates for approximately one year from one AA battery
The Vaisala PTB110 is a compact, low-power barometer for accurate atmospheric-pressure measurement and integration with data loggers, weather stations and environmental monitoring systems.
Selectable barometric-pressure ranges from 500 to 1100 hPa
The Vaisala PTB330 provides accurate, stable barometric-pressure measurement for professional meteorology, aviation, maritime systems, laboratories and demanding environmental applications.
500 to 1100 hPa or extended 50 to 1100 hPa pressure range
Accuracy up to ±0.10 hPa at +20 °C
Choice of one, two or three Vaisala BAROCAP® pressure sensors
Optional graphical display with trends and measurement history
RS-232 with optional RS-485, RS-422 and analogue outputs
WMO pressure trend and tendency calculations
IP66 housing without display for demanding installations
The Vaisala PDT101 and PDT102 provide precise low differential-pressure measurement for cleanrooms, isolation rooms, regulated facilities, data centres and air-handling systems.
PDT101 accuracy up to 0.40% of span
PDT102 high accuracy up to 0.25% of span
4–20 mA or voltage output configurations
Compatible with Vaisala viewLinc monitoring solutions
The Sato 7610-20 is a traditional brass aneroid barometer with an integrated glass thermometer for local atmospheric-pressure and temperature observation.
Atmospheric-pressure range from 930 to 1070 hPa
Secondary pressure scale from 700 to 800 mmHg
Movable index pointer helps indicate pressure change
Glass thermometer covering −10 to +50 °C
Fully mechanical and requires no battery or external power
The Sato Baromex 7612-00 combines an easy-to-read analogue barometer with a digital thermometer for local atmospheric-pressure and room-temperature indication.
Atmospheric-pressure range from 945 to 1045 hPa
Dual pressure scale in hPa and mmHg
Movable index pointer helps indicate pressure change
The Vaisala PTU300 combined barometric pressure, relative humidity and temperature in one transmitter. The series is discontinued and has been replaced by a suitable Indigo520 barometric-pressure configuration with an application-specific HMP probe.
Legacy three-in-one pressure, humidity and temperature transmitter
PTU301, PTU303, PTU304, PTU305, PTU307 and PTU308 variants
Former applications include laboratories, meteorology and semiconductor measurement
Current replacement platform: Indigo520 with barometric-pressure measurement
Humidity probe selected according to mounting and process conditions
Existing wiring, outputs and process connections require migration review
The Vaisala DPT145 provides online dew-point, pressure and temperature measurement for SF6-insulated electrical equipment. The model is being discontinued and should not be specified for new projects.
Measures dew point, pressure and temperature
Calculates SF6 density, normalised pressure and moisture in ppm
RS-485 communication with Modbus RTU
Contact Seacom for availability and replacement assessment