The SPI MM800 electromagnetic flowmeter measures electrically conductive liquids using Faraday's law of induction. Different sensor and converter arrangements are available to suit the pipework, installation location and indication requirements.
Electromagnetic measurement for electrically conductive liquids
No moving measuring parts in the flow sensor
Compact, remote and battery-powered converter options
Flanged, wafer, tri-clamp and insertion sensor configurations
Configuration selected to match the liquid and operating conditions
The SPI MG Series oval gear flowmeter measures liquid volume using positive displacement technology. Pulse signals can be connected to a compatible indicator, PLC or batch controller.
Direct volumetric measurement of compatible clean liquids
Measurement principle does not depend on liquid conductivity
Pulse output for remote counting and control applications
Display and controller options to suit the installation
Batch measurement when paired with a suitable control system
The TOKICO PFA ultrasonic vortex flowmeter measures compatible chemicals, corrosive liquids and ultrapure water using PFA liquid-contacting construction.
No moving parts.
Connection sizes: 3/8, 1/2, 3/4 and 1 inch.
Fluid temperature range: 0–100°C.
Flow range and pressure rating depend on size and operating conditions.
Local display with output functions according to configuration.
The Badger Meter ModMAG M2000 measures conductive liquid flow, with applications in data centre chilled-water and cooling-water systems. Communication options support integration with building and plant monitoring systems.
Flow velocity range: 0.03–12 m/s
Accuracy: ±0.20% of reading ±1 mm/s with suitable straight pipe
Integral or remote transmitter arrangements
BACnet, Modbus and other communication options
Zero-straight-run capability subject to specified conditions
The Tokico MBA Series is an electrical signal-operated emergency shut-off valve using a CO₂ cartridge to power the cylinder actuator and close a ball valve.
Catalogue connection sizes from 25 to 400 mm.
CO₂-powered actuation without a plant compressed-air supply.
Electrical triggering through suitable control equipment.
Manual reset and horizontal or vertical piping installation.
Contact Seacom to confirm fluid compatibility, pressure, flange specification and control requirements.