Choose the Right Type of Barometer

Instrument typeMain purposeWhat to check
Analogue aneroid barometer Local atmospheric-pressure indication on a dial Scale readability, measuring range, installation altitude and adjustment requirements
Digital barometer Electronic atmospheric-pressure measurement Accuracy, temperature performance, display availability and communication options
Barometric pressure transmitter Pressure signals for a logger, controller or monitoring system Power supply, output signal, scaling and receiving-system compatibility
Recording barograph Atmospheric-pressure trends recorded on a paper chart Recording period, chart range, consumables and maintenance

Barometer and Barograph Product Selection

ProductMeasurement approachApplication to consider
Vaisala PTB330 Digital barometric-pressure measurement Precision atmospheric-pressure measurement for weather, laboratory and marine applications. Confirm the required display and output configuration.
Vaisala PTB110 Barometric pressure transmitter Integration into weather stations, environmental monitoring equipment and data-acquisition systems.
Sato 7610-20 Aneroid pressure dial with glass thermometer Local atmospheric-pressure and temperature observation using a mechanical instrument.
Sato Baromex 7612-00 Analogue pressure dial with digital thermometer Local pressure observation with a separate digital temperature indication.
Sato NSII-BQ Barograph Atmospheric-pressure recording on a paper chart Applications requiring a visible record of pressure changes over time.

Confirm the exact model, configuration and availability before ordering. For an existing installation, provide the instrument model and the measurement or recording functions that must be retained.

Applications for Barometric Pressure Measurement

  • Weather observation: Measure atmospheric pressure and follow changes over time.
  • Laboratories: Record ambient pressure where it is relevant to a measurement procedure or environmental record.
  • Marine applications: Select suitable instruments for atmospheric-pressure observation and weather-system integration.
  • Environmental monitoring: Connect compatible pressure transmitters to data loggers or monitoring equipment.
  • Local observation and chart recording: Choose a readable dial or recording barograph according to the required record format.

What to Check Before Selecting a Barometer

  • Pressure range: Confirm the expected atmospheric pressure at the installation altitude.
  • Accuracy and resolution: Display resolution alone does not establish measurement accuracy.
  • Operating temperature: Review performance across the actual environmental conditions.
  • Display or output: Decide whether you need local indication, an electrical signal, recorded data or a combination.
  • Recording method: Choose between a paper chart and a compatible electronic logging arrangement.
  • Calibration: Specify any certificate, traceability and periodic checking requirements.
  • Installation: Check mounting, environmental protection, pressure-port arrangements and access for servicing.

Installation and Pressure Reference

Atmospheric pressure varies with altitude. A local barometer reading may differ from a weather report that presents pressure corrected to sea level. Before comparing readings, confirm the pressure reference and any correction applied.

Install the instrument according to its instructions. For precision measurement, consider pressure disturbances caused by ventilation systems or wind at the sensing location. Protect the instrument from conditions outside its specified operating limits.

Barometric Pressure or Differential Pressure?

Barometric pressure describes atmospheric pressure measured against an absolute reference. Differential pressure describes the difference between two pressure points, such as adjacent rooms or the two sides of a filter.

For cleanroom pressure relationships, filter monitoring or other process-pressure requirements, explore our pressure measurement instruments . For related recording equipment, see pressure recorders and data loggers .

Frequently Asked Questions

What is the difference between a barometer and a barograph?

A barometer indicates atmospheric pressure. A recording barograph also produces a pressure history, typically by tracing the measurement onto a moving paper chart.

Is a digital barometer always more accurate than an analogue model?

Not automatically. Compare the specified accuracy, measuring range, temperature performance and calibration requirements of the individual instruments. A digital display with more decimal places does not necessarily mean higher accuracy.

Does a barometer with a digital thermometer measure pressure digitally?

Not necessarily. Some instruments combine a mechanical pressure dial with a digital temperature display. Check how each parameter is measured and displayed.

Can a barometer be connected to a data logger?

Yes, if the selected instrument provides an output compatible with the logger. Check the signal type, power supply, wiring and scaling. A mechanical dial barometer does not normally provide an electrical measurement output.

Why does my barometer differ from a weather website?

The two readings may use different pressure references, locations or observation times. Check whether the weather service reports sea-level pressure and whether your instrument displays local atmospheric pressure before considering an adjustment.

Seacom Product Selection and Technical Support

Seacom Process Instruments supplies measurement instruments and provides technical support for product selection, installation requirements and system integration. Our team can help review your application and identify a suitable model, configuration and accessories.

For barometer enquiries, share your application, installation altitude, required accuracy, display or recording preference, and any output or calibration requirements.

Email: seacom@seacom.com.my

WhatsApp: +60 16 208 0697

Barometer

Active filters

Barograph NSII-BQ

Barograph NSII-BQ

Sato Barograph NSII-BQ (Cat No 7237-00)

Barograph measures atmospheric pressure with the range of 940 to 1045 hPa and records the measured data on a chart..

Recording period is changeable in 1 day, 7 day and 32 day by the cylinder speed switch.

One box (55 sheets/box) of 7-day chart for one year use is included.

Vaisala PTB330 High-Accuracy Digital Barometer

Vaisala PTB330 High-Accuracy Digital Barometer

The Vaisala PTB330 provides accurate, stable barometric-pressure measurement for professional meteorology, aviation, maritime systems, laboratories and demanding environmental applications.

  • 500 to 1100 hPa or extended 50 to 1100 hPa pressure range
  • Accuracy up to ±0.10 hPa at +20 °C
  • Choice of one, two or three Vaisala BAROCAP® pressure sensors
  • Optional graphical display with trends and measurement history
  • RS-232 with optional RS-485, RS-422 and analogue outputs
  • WMO pressure trend and tendency calculations
  • IP66 housing without display for demanding installations
Vaisala PTB330TS Barometric Pressure Transfer Standard

Vaisala PTB330TS Barometric Pressure Transfer Standard

The Vaisala PTB330TS is a portable, battery-operated reference instrument for accurate barometric-pressure checks in the field and laboratory.

  • PTB330 digital barometer with Vaisala BAROCAP® technology
  • Handheld MI70 indicator with graphical display and data logging
  • 500 to 1100 hPa barometric-pressure range
  • Class A pressure accuracy for demanding reference measurements
  • Optional HMP155 probe for humidity and temperature measurement
  • Available with one, two or three pressure modules
  • Supplied in a durable weatherproof transport case
Vaisala PTB110 Analogue Barometric Pressure Transmitter

Vaisala PTB110 Analogue Barometric Pressure Transmitter

The Vaisala PTB110 is a compact, low-power barometer for accurate atmospheric-pressure measurement and integration with data loggers, weather stations and environmental monitoring systems.

  • Selectable barometric-pressure ranges from 500 to 1100 hPa
  • Accuracy up to ±0.3 hPa at +20 °C
  • 0–2.5 V, 0–5 V or frequency-output options
  • Less than 4 mA current consumption
  • External trigger supports power-saving operation
  • Compact DIN-rail-mountable construction
Barometer with Thermometer Analog

Sato 7610-20 Aneroid Barometer with Glass Thermometer

The Sato 7610-20 is a traditional brass aneroid barometer with an integrated glass thermometer for local atmospheric-pressure and temperature observation.

  • Atmospheric-pressure range from 930 to 1070 hPa
  • Secondary pressure scale from 700 to 800 mmHg
  • Movable index pointer helps indicate pressure change
  • Glass thermometer covering −10 to +50 °C
  • Fully mechanical and requires no battery or external power
  • Buffed brass case with a glass front
  • Specified for installation up to 500 m altitude
Vaisala PTU300 Pressure, Humidity and Temperature Transmitter – Discontinued

Vaisala PTU300 Pressure, Humidity and Temperature Transmitter – Discontinued

The Vaisala PTU300 combined barometric pressure, relative humidity and temperature in one transmitter. The series is discontinued and has been replaced by a suitable Indigo520 barometric-pressure configuration with an application-specific HMP probe.

  • Legacy three-in-one pressure, humidity and temperature transmitter
  • PTU301, PTU303, PTU304, PTU305, PTU307 and PTU308 variants
  • Former applications include laboratories, meteorology and semiconductor measurement
  • Current replacement platform: Indigo520 with barometric-pressure measurement
  • Humidity probe selected according to mounting and process conditions
  • Existing wiring, outputs and process connections require migration review
Sato Baromex 7612-00 Barometer with Digital Thermometer

Sato Baromex 7612-00 Barometer with Digital Thermometer

The Sato Baromex 7612-00 combines an easy-to-read analogue barometer with a digital thermometer for local atmospheric-pressure and room-temperature indication.

  • Atmospheric-pressure range from 945 to 1045 hPa
  • Dual pressure scale in hPa and mmHg
  • Movable index pointer helps indicate pressure change
  • Digital temperature display from 0 to 50 °C
  • Rear °C/°F temperature-selection switch
  • Compact wall mounting with the supplied bracket
  • Powered by one AA battery