The Hyoda AY Series provides local temperature indication with a stainless steel exterior and IP65 protection.
The Hyoda AY Series provides local temperature indication using a bimetal sensing element and a dial mounted at the sensing stem. Its stainless steel exterior and IP65 enclosure suit installations requiring a protected mechanical temperature display.
Choose AY4 or AY5 for a standard head arrangement, or AY4-QS or AY5-QS when an adjustable viewing angle helps make the dial easier to read. Specify the temperature scale, stem dimensions and connection to suit the measurement point.
| Model | Dial diameter | Head arrangement | Protection |
|---|---|---|---|
| AY4 | 100 mm | Standard | IP65 |
| AY5 | 125 mm | Standard | IP65 |
| AY4-QS | 100 mm | Adjustable angle | IP65 |
| AY5-QS | 125 mm | Adjustable angle | IP65 |
| Specification | Details |
|---|---|
| Measuring principle | Bimetal |
| Available range coverage | −50 to 500°C; select a suitable standard scale |
| Function | Temperature indication; no microswitch |
| Listed stem diameters | 8, 10 or 12 mm |
| Listed stem lengths | 85 to 500 mm |
| Listed construction | SUS304 stainless steel; SUS316 on request, tempered glass and aluminium dial plate |
| Listed accuracy | ±1.5 to ±2.0% of full scale; special ±1.0% of full scale on request |
The range coverage does not mean every instrument has a −50 to 500°C scale. Stem, material and accuracy options depend on the selected configuration; confirm the complete specification before ordering. Accuracy expressed as a percentage of full scale is different from a percentage of the measured reading.

| Product / range | Instrument type | Display / arrangement | Indication / switching | Protection | Selection focus |
|---|---|---|---|---|---|
| M Series | Fluid-filled; M3/M4/M6 and WP versions | 75 / 100 / 150 mm; remote bulb | Optional pointer contacts; M3: one, M4/M6: one or two | IP43; WP: IP65 | Remote reading with a choice of dial sizes |
| S6 / S6-WP | Fluid-filled | 150 mm; remote bulb | Indication only or one/two pointer contacts | IP43; WP: IP65 | Large dial for remote temperature indication |
| AY Series | Bimetal; AY4/AY5 and QS versions | 100 / 125 mm; stem-mounted; QS adjustable head | Temperature indication | IP65 | Local reading at the sensing stem |
| KME-2 / KME-4 | Fluid-filled; wall-mounted | KME-2: with indicator; KME-4: without indicator | One microswitch contact | IP43 | Temperature switching with or without local indication |
| ES-UT | Liquid-filled; wall-mounted | Remote sensing bulb | One or two microswitch contacts | IP65; published explosion-proof designation d2G4 | Applications requiring a suitable explosion-protected controller; confirm approval suitability |
| Fluid-Filled Thermometer Range | General range listing; multiple configurations | Depends on selected model | Depends on selected model | Depends on selected model | Explore other Hyoda temperature indication and control options |
The Fluid-Filled Thermometer Range is an overview listing, not a single model with one specification. Compare the exact model, temperature scale, sensing bulb, connection and mounting before ordering. S6 and M6 both have 150 mm dials, but this does not establish interchangeability.
Contact Seacom with your temperature range, dial size, stem diameter, insertion length and connection requirements. For a replacement, include photographs of the existing thermometer, model markings and mounting arrangement so we can help identify a suitable configuration.
.