Model |
AR-6500 |
Measurement Range |
-50.0 to 500.0°C |
Resolution |
0.1°C |
Field of view |
Fig1 |
Measurement Accuracy
(Non-Contact) |
-50.0 to -0.1°C |
±3°C±1digit |
0.0 to 250.0°C |
±2°C±1digit |
250.1 to 500.0°C |
± (0.8% of reading + 1digit) |
Delector |
Thermopile |
Spectral response |
8~14μm |
Repeatability |
± (0.4% of reading + 1digit) |
Response time |
approx. 300ms |
A-constant adjustment |
0.10 to 2.00 (0.01 step) |
Laser aiming |
L2 models meet IEC Class2 |
Reference junction compensation accuracy |
±0.2°C at 25±10°C |
Temperature coefficient |
±0.01% of full scale °C |
Power supply |
Ni-Cd rechargeable battery (4AA) |
Battery life |
30 hours to (10 hours when laser is used continuously) |
Environmental limit(Operation) |
0 to 40°C, 0 to 80%RH (Without Dew) |
Environmental limit (Storage ) |
-20 to 50°C, 0 to 85%RH (Without Dew) |
Dimensions |
Fig2 |
Weight |
App. 400g |
Contact mode |
Input |
Thermocouple Type : K
ANP connector (Miniture plug) |
Measurement Range |
-50.0 to 500.0°C |
Measurement Accuracy |
± (0.05% of reading + 0.1°C) ±1digt |
Sampling time |
approx. 300ms |
Linearlizer |
Digital Linearizer method (Compliant with IEC 60584-1 (2013)) |
Accessories |
Manual, Soft case, Lens cap, Charger, Test report |