The Sato SK-8950 measures surface temperature without contact, with a circular laser marker and adjustable emissivity to suit different materials.
For industrial surface measurements; not intended for clinical body-temperature measurement.
The Sato SK-8950 is a handheld infrared thermometer for non-contact surface temperature checks from −60 to 550°C. Its circular laser marker helps with aiming, while adjustable emissivity allows the setting to be matched to the material being measured.
It is a practical option for comparing surface temperatures during maintenance, production checks and heating or cooling investigations. The IP54 enclosure provides protection against dust ingress and water splashes for everyday industrial handling.

| Specification | SK-8950 |
|---|---|
| Catalogue number | 8269-00 |
| Measuring range | −60 to 550°C |
| Accuracy: 0 to 550°C | ±2°C or ±2% of reading, whichever is greater |
| Accuracy: below 0°C | ±(2°C + 5% of the reading magnitude) |
| Accuracy conditions | Blackbody measurement at 23 ±3°C ambient temperature and emissivity 0.95 |
| Display resolution | 0.1°C |
| Response time | Approximately 1 second to reach 90% of the response |
| Emissivity adjustment | 0.10 to 1.00, in 0.01 steps |
| Distance-to-spot ratio | Approximately 12:1 |
| Detector / spectral range | Thermopile / 8–14 μm |
| Laser marker | Red circular laser; Class II; 650 nm; output below 1 mW |
| Ingress protection | IP54: dust protection and resistance to splashing water |
| Operating temperature | 0 to 50°C, without condensation |
| Power supply | Two AAA alkaline batteries |
| Battery life | Approximately 14 hours of continuous measurement with laser and backlight on, under normal temperature conditions |
| Dimensions | Approximately 42 W × 143 H × 80 D mm |
| Weight | Approximately 196 g including batteries |
| Supplied accessories | Two AAA alkaline batteries, neck strap and instruction manual |

The thermometer measures an area rather than a single point. As the distance increases, the measurement area becomes larger. At a distance of approximately 600 mm, the spot diameter is approximately 50 mm.
Keep the target larger than the measuring spot so surrounding surfaces do not contribute unwanted temperature information. Sato defines the spot using the area receiving 90% of the target’s emitted energy.

The laser circle is an aiming guide. Sato specifies that the laser circle and actual measuring area coincide at a measurement distance of 2,000 mm. At other distances, allow for the difference between the laser indication and the infrared measuring area.

Set upper and lower limits to receive a buzzer alert when a reading moves outside the selected limits. MAX and MIN show the extremes during measurement, AVG displays the average, and DIF shows the difference between maximum and minimum readings.
Automatic measurement mode allows continuous operation without holding the trigger. During normal trigger operation, the last reading remains on screen for one minute after release before automatic power-off.
The IP54 rating supports use with wet hands and protection from splashes; it is not an immersion rating. Keep the optical window clean and follow the manufacturer’s cleaning instructions. The Class II laser must not be directed at anyone’s eyes.
The SK-8950 is an industrial surface thermometer and is not intended for clinical body-temperature measurement.
Contact Seacom Process Instruments Sdn Bhd with the target material, surface finish, temperature range, object size and measuring distance. We can help you assess whether the SK-8950 suits the task or whether a contact probe would be more appropriate.
Download |
.
.