Hyoda (Japan) Explosion Proof (d2G4)Thermometer ES-UT
.
Humidity and Temperature Probe HMP3
for general purpose humidity and temperature applications with exchangeable sensor
Vaisala HUMICAP® Humidity and Temperature Probe HMP3 is a general-purpose probe designed for processes with moderate humidity and temperature levels. The probe structure allows the sensor to be replaced in the field without tools, making it suitable for applications such as industrial HVAC systems, paint booths, cleanrooms, environmental chambers, and applications where periodic recalibration is not sufficient for maintenance.
HMP3 is part of the Indigo family and is compatible with Indigo500 and Indigo200 series transmitters. It can be used with Vaisala Insight PC software for data visualization, easy probe configuration, and field calibration.
Humidity and Temperature Probe HMP5
for high temperature humidity and temperature applications with exchangeable sensor
Vaisala HUMICAP® Humidity and Temperature Probe HMP5 is designed for high temperature applications such as baking ovens, pasta dryers, ceramics and industrial drying kilns where measurement performance and chemical tolerance are essential
HMP1 is part of the Indigo family and is compatible with Indigo500 and Indigo200 series transmitters. It can be used with Vaisala Insight PC software for data visualization, easy probe configuration, and field calibration.
EDL Practi-Cal (PRI) Dry Well / Surface Calibrator (PRI) allows for easy testing and verification of virtually any size or shaped surface and insertion-style sensor – in one compact package. Utilizing an interchangeable dry well system, this calibrator has a uniform flat surface alongside a custom drilled insertion dry well. The PRI is ideal for use in the lab or in the field. It weighs in at under 30lbs., and can be taken virtually anywhere.
Vaisala's multi-application temperature data logger monitors temperatures in up to four applications with one logger – ultra-low temperature freezers, freezer/refrigerators and incubators. A superior alternative to chart recorders and hard-wired systems.
Vaisala DL1000, DL1016, 1400, DL1416 is a high-accuracy temperature data logger. Ideal for ultra-low temperature freezers, fridges, cold rooms in regulated environments, the DL1000-1400 temperature logger provides stable, reliable measurements. With a measurement range from -90 °C to +70 °C and stable accuracy at ±0.10°C, the DL1000-1400 series can take up to four inputs for monitoring or mapping temperatures in that range. This series also offers an optional input for door monitoring
The DL-series temperature loggers connect to Vaisala's viewLinc software to provide historical and real-time data, remote alarming, and reporting in compliance with global regulations and standards. The Vaisala OPC-DA Server software can be used to integrate Vaisala DL-series data loggers to non-Vaisala systems. If access to historical measurements is needed, the Vaisala OPC-UA Server can be used to integrate the viewLinc database with non-Vaisala systems.
Hyoda (Japan) Waterproof Bimetal Thermometer M series
Model: M3, M4, M6
for Vaisala's Smart Humidity, Temperature, Dew Point, Moisture in Oil, CO2 and H2O2 Probes
Vaisala Indigo200 Series host devices are part of Vaisala Indigo product family and intended for Vaisala's intelligent, stand-alone humidity probes (HMP1, HMP3, HMP4, HMP5, HMP7, HMP8 and HMP9), dew point probes (DMP5, DMP6, DMP7 and DMP8), temperature probe (TMP1), CO2 probes (GMP251 and GMP252), moisture in oil probe MMP8, as well as our vaporized hydrogen peroxide probe series HPP270: including HPP271 to measure hydrogen peroxide vapor (ppm), or the HPP272 to measure hydrogen peroxide vapor (ppm), temperature, and humidity (relative humidity and relative saturation). The HPP272 probe includes other calculated parameters such as dew point and vapor pressure measurements..
Looking for a transmitter with a metal enclosure? See Indigo500 series with dual-probe support and many more additional features.
Typical applications for the Indigo200 include industrial and compressed air drying, life science incubators, hatchers and setters, greenhouses, cold storage & refrigeration, food transportation, CO2 safety, hydraulic and lubrication oil monitoring, demanding HVAC such as animal shelters, swimming pools, parking garages, and facilities using vaporized hydrogen peroxide decontamination.
Vaisala Indigo 200 allows for easy evaluation and visualization of data, also wirelessly. The installation is uncomplicated, which saves time. Watch video on how to install Indigo201 and configure analog outputs. Also the probe types are interchangeable reducing downtime. The enclosure with an IP65 classification is safe for harsh environments and resistant to dust and most chemicals. The smooth surface of the enclosure makes cleaning easy.
Hyoda (Japan) Thermometer with MicroSwitch Model KME-2, KME-4.
EDL’s Single Black Body (SBB) IR Calibrators were designed for easy and reliable testing of virtually any in line or handheld infrared pyrometer/gun. The Single Black Body (SBB) is used for applications requiring only one temperature range. Lightweight and compact, the SBB is ideal for use in the lab or in the field. Units are available to cover the most tested temperatures: SBB-1 (low-range) accommodates temperatures from -30 °C up to 110 °C, SBB-2 (mid-range) accommodates temperatures from ambient up to 350 °C, and SBB-3 (high-range) accommodates temperatures from ambient up to 650 °C.
The wall-mounted Vaisala GMW90 Series CARBOCAP® Carbon Dioxide, Temperature and Humidity Transmitters are especially suited for green building projects and demand controlled ventilation. The devices measure carbon dioxide and temperature and have an option for an additional humidity measurement.
The instruments come with a calibration certificate that meets traceability and compliance requirements. Traceability is easily maintained with field-exchangeable intelligent measurement modules. The transmitter can be blended into the interior design of the space where it is installed using the optional decorative cover.
The Vaisala HMW90 Series has been complemented with four new models: TMW92 and TMW93 temperature transmitters for applications where only temperature measurement is needed and the configurable HMW90 and TMW90 for special scalings.
The HMW90 and TMW90 transmitters are available in four color options: standard white, black, grey and ivory.
The Vaisala Dewpoint, Pressure and Temperature Multiparameter Transmitter DPT145 for SF6 Gas is a unique innovation that enables online measurement of dew point, pressure, and temperature. It also calculates four other values, including SF6 density. The DPT145 is especially well suited for integration into OEM systems.
- First transmitter to offer online measurement of seven SF6 parameters in one unit
- Measured parameters: dew point, pressure, temperature
- Calculated parameters: SF6 density, normalized pressure, dew point in atmospheric pressure, ppm
- Saves time and money across the board, from investment and installation to operation and servicing
- More reliable assessment of the condition of SF6 insulation due to online measurement
- Long calibration interval of years
The DL1700 thermocouple data loggers provide accurate temperature data acquisition, remote alarming, and continuous monitoring.
The loggers are ideal for demanding environments that use extreme temperatures, from -240 °C to 1760 °C; applications such as liquid nitrogen (LN2), ovens, sterilization chambers and other extreme temperatures in laboratories and industrial environments.
The loggers connect to Vaisala's viewLinc software to provide historical and real-time data, remote alarming, and reporting in compliance with global regulations and standards.
The Vaisala OPC-DA Server software can be used to integrate Vaisala DL-series data loggers to non-Vaisala systems. If access to historical measurements is needed, the Vaisala OPC-UA Server can be used to integrate the viewLinc database with non-Vaisala systems.
Hyoda (Japan) Explosion Proof (d2G4)Thermometer ES-UT