Features
- Measurement with high accuracy
Because the fluid is directly measure, the integration accuracy of this flow meter is within ±0.5% (The accuract within ±0.2 is also available according to the demands for a dealing and a tax certificate, etc.) Especially, because a pair of roots is non-contact, a light material can be adopted for the TOKICO FLOWMETER. And low viscosity fluids can be measured with high accuracy and wide flow range.
- Small size and light weight
Because the roots is adopted for the rotor, discharging fluid volume in one rotation of rotor is larger and the roots meter is designed small and light.
- Excellent stability of accuracy
Mechanical parts of the roots meter do not wear because of non-contact rotation and there is little change of instrument accuracy in a long time operation.
Because the roots meter rotates without contact, the rotor is excellent in durability.
The pressure loss is smaller than another displacement type flow meter because the rotors do not contact each other.
Suitable for:
- Light Fuel Oil (Diesel)
- Crude Palm Oil (CPO)
- Heavy Oil
- Other oil
Electronic Version (Click Picture to View)
|
We also provide accredited calibration service for Tokico flowmeter
We stock Tokico flowmeters and strainers from 1/2" to 4", feel free to send us an inquiry at seacom@seacom.com.my, international shipping available!
|
|
Model |
FRO Flowmeter |
Accuracy |
±0.5% |
Flow range |
Refer to next table |
Max Working Pressure |
10kgf/cm2 |
Max Working Temperature |
50 ºC kerosene and light oil 100ºC for heavy oil(120ºC with the FGB-00X AND FGB-02X types) |
Flange Rating |
JIS 10 kgf/cm2FF |
Material |
Body: FGB type: Bore 156mm - FC250 (Cast Iron), Bore 20, 25mm - FCD400 (Ductile Iron) FRO type: FC250 * 1 Rotor: FGB type: Resin FRO type: Aluminium alloy casting |
Counter Unit |
Integrating pointer and integrating counter (a reset conter is also available) |
Electricle Transmitter Unit |
Transmitter: FGB type: Reed switch (S), FRO type: Microswirch (M) Power Supply: AC100V, 50/60Hz as standard Number of Pulse: 0~5 PPS Output Signal: ON - OFF contact Transmission Cable 2-Wire cable with cabtype |
Flow Direction |
Right to Left |
Paint Color |
Munsell 1.4PB3.1/1.2 |
Model |
Bore(mm) |
Direct-reading integrating type |
Direct-reading integrating type with reset counter |
Pointer |
Number of digits |
Minimum unit |
FGB type |
15 |
FGBB423BAL-00X/02X |
FGBB423BAL-04X |
1 |
7 (6 digits for 00X type) |
1 |
FGB type |
20 |
FGBB631BDL-00X/02X |
FGBB631BDL-04X |
10 |
7 (6 digits for 00X type) |
10 |
FGB type |
25 |
FGBB835BDL-00X/02X |
FGBB835BDL-04X |
10 |
7 (6 digits for 00X type) |
10 |
FRO type |
40 |
FR00438-02X (RO11AB-1-A4) |
FR00438-04X (RO11AB-2-A4) |
10 |
7 |
10 |
FRO type |
50 |
FR00541-02X (RO12-1-A4) |
FR00541-04X (RO12-2-A4) |
10 |
7 |
10 |
Model |
Bore (mm) |
Flow Range (l/h) (Accuracy ±0.5%) |
FGB
|
15 |
Fluid |
Kerosene
Light oil
|
A heavy oil |
B, C heavy oil |
20 |
Viscosity |
1.2~3cP |
10cP |
50~300cP |
25 |
Normal operation |
10~200 |
5~200 |
- |
40~1250 |
20~1250 |
10~1250 |
150~3000 |
50~3000 |
25~1250 |
FRO |
40 |
Normal Operation |
Intermitent |
800~6000 |
100~7000 |
50~7000 |
Continuous |
800~4500 |
100~6000 |
50~6000 |
Max. |
7000 |
8000 |
8000 |
50 |
Normal operation |
Intermitent |
1500~13000 |
250~15000 |
100~15000 |
Continuous |
1500~9000 |
250~13000 |
100~13000 |
Max. |
15000 |
17000 |
17000 |
80 |
Normal Operation |
Intermitent |
3500~35000 |
600~40000 |
300~40000 |
Continuous |
3500~25000 |
600~35000 |
300~35000 |
Max |
40000 |
45000 |
45000 |
Meter Type |
Bore (mm) |
|
Flow Range(l/h) (Accuracy: 0.5%) For Oil |
|
Fluids |
Gasoline |
Kerosene |
Light Oil |
A Heavy Oil |
B Heavy Oil |
C Heavy Oil |
Conditions |
Viscosity |
0.3~0.7 mPa's |
0.9~2.5 mPa's |
2~4 mPa |
5~10 mPa |
50 mPa's |
150 mPa's |
FRP |
50 |
Normal Operation |
Intermittent |
5~35 |
3.5~25 |
1.8~35 |
0.6~35 |
0.3~35 |
0.15~35 |
Continuous |
5~25 |
3.5~25 |
1.8~35 |
0.6~35 |
0.3~35 |
0.15~35 |
Max. |
40 |
40 |
45 |
45 |
45 |
45 |
FRP |
80 |
Normal Operation |
Intermittent |
8~50 |
5~50 |
2.5~50 |
1~50 |
0.5~50 |
0.25~50 |
Continuous |
8~35 |
5~35 |
2.5~50 |
1~50 |
0.5~50 |
0.25~40 |
Max. |
55 |
55 |
60 |
60 |
60 |
60 |
FRP |
100 |
Normal Operation |
Intermittent |
16~120 |
12~120 |
8~130 |
4~130 |
2~130 |
0.7~130 |
Continuous |
16~85 |
12~85 |
8~120 |
4~120 |
2~120 |
0.7~120 |
Max |
130 |
130 |
140 |
140 |
140 |
140 |
FRP |
100 |
Normal Operation |
Intermittent |
20~110 |
15~110 |
10~140 |
8~140 |
6~140 |
3~140 |
Continuous |
20~150 |
15~150 |
10~160 |
8~160 |
6~160 |
3~160 |
Max |
160 |
160 |
170 |
170 |
170 |
170 |
Model
|
Bore (mm)
|
Direct-reading integrating type with reset counter
|
Pointer
|
Number of Digits
|
One Revolution
(L/rev)10-1
|
Minimum Scale (L) |
FRP |
80 |
FRP0845BAA-04X2-X |
100 |
1 |
10 |
FRP |
80 |
FRP0847BAA-04X2-X |
100 |
1 |
10 |
FRP |
100 |
FRP1051BAA-04X2-X |
100 |
1 |
10 |
FRP |
100 |
FRP1052BAA-04X2-X |
100 |
1 |
10 |
|