Vaisala DL1000, DL1400, DL1016 and DL1416 temperature data loggers provide reliable, traceable monitoring for refrigerators, freezers, cold rooms, incubators and regulated facilities.
The Vaisala DL1000 and DL1400 series are precision temperature data loggers for continuous monitoring and validation work. Available with two or four channels and a choice of internal or external sensors, they can cover applications ranging from warehouses and incubators to ultra-low-temperature freezers.
The DL1016 and DL1416 are the external-probe configurations. The DL1016 provides two external channels, while the DL1416 provides four, allowing one logger to monitor several cabinets, chambers or measurement positions.
When connected to the Vaisala viewLinc Continuous Monitoring System, the loggers provide historical and real-time data, remote alarms and controlled reporting. They can also be used with Vaisala vLog for validation and mapping.
| At a Glance | DL1000–DL1416 Series |
|---|---|
| Channel configurations | 2 or 4 channels, depending on model |
| External-probe calibrated ranges | −25 to +70 °C with N-range probes; −90 to −40 °C with V-range probes |
| Recording | Autonomous onboard memory with user-selectable sampling intervals |
| Power | Internal lithium battery with a typical 10-year life at intervals of one minute or longer |
The Vaisala VDL200 is the current replacement platform for many DL1000, DL1400, DL1016 and DL1416 continuous-monitoring applications. It uses interchangeable smart probes and a native Ethernet or Power over Ethernet connection to the viewLinc system.
| Consideration | Legacy DL1000–DL1416 Series | Current VDL200 Platform |
|---|---|---|
| Product generation | DL-series platform approaching phase-out | Current-generation viewLinc data logger |
| Measurement arrangement | Internal or fixed channel-specific temperature configuration | Interchangeable smart probes selected for the application |
| Channels | Two- or four-channel configurations | Up to two probe ports and multiple recorded parameters, depending on probe selection |
| Network connection | RS-232 with optional USB, Ethernet, PoE or Wi-Fi interface | Native Ethernet and Power over Ethernet with battery backup |
| Migration requirement | Existing systems may remain in service | Probe range, channel quantity, cabling, network and viewLinc compatibility must be checked |
| Model Family | Configuration | Suitable Applications |
|---|---|---|
| DL1000 | Two-channel platform with internal and external sensor configurations | Single cabinets, rooms and equipment requiring one or two measurement points |
| DL1400 | Four-channel platform with internal and external sensor configurations | Several measurement points located close together |
| DL1016 | Two external V-range temperature channels | Two freezers, refrigerators or external probe positions |
| DL1416 | Four external V-range temperature channels | Multi-application monitoring or mapping with up to four probes |
| Sensor Option | Calibrated Range | Typical Application |
|---|---|---|
| Internal sensor | −25 to +70 °C | Rooms, warehouses and chambers where the complete logger can be installed at the measurement point |
| N-range external probe | −25 to +70 °C | Refrigerators, incubators and general temperature monitoring |
| V-range external probe | −90 to −40 °C | Ultra-low-temperature freezers and other low-temperature equipment |
External probes are calibrated with their assigned logger channel. Keep each probe paired with the correct channel to maintain the stated system accuracy.
| Software | Purpose |
|---|---|
| viewLinc Enterprise Server | Continuous monitoring, remote alarms, audit trails, access control and reporting |
| vLog VL | Validation and mapping for GxP-regulated applications |
| vLog SP | Graphing and reporting for non-GxP applications |
| OPC integration | Makes compatible live or historical monitoring data available to third-party systems |
The complete viewLinc system can support records and workflows designed to meet FDA 21 CFR Part 11 and EU GMP Annex 11 requirements. Compliance depends on the complete system configuration, validation and operating procedures.
| Sampling interval | User selectable from once every 10 seconds to once per day |
| Memory | Non-volatile EEPROM |
| DL1000-series capacity | 48,100 12-bit samples |
| DL1400-series capacity | 85,300 12-bit samples |
| DL1016-series capacity | 68,600 16-bit samples |
| DL1416-series capacity | 101,375 16-bit samples |
| Memory modes | Wrap when full (FIFO) or stop when full |
| Connectivity | RS-232 serial; USB, Ethernet, Wi-Fi or PoE using the appropriate interface |
| Internal clock accuracy | ±1 minute/month within the specified operating range |
| Dimensions | 85 × 59 × 26 mm |
| Weight | 76 g |
| Monitoring Requirement | Recommended Logger |
|---|---|
| Two or four precision temperature channels | DL1000 / DL1400 / DL1016 / DL1416 |
| Thermocouple measurement from cryogenic to very high temperatures | DL1700 |
| Temperature and relative humidity | DL2000 |
| Current, voltage or other analog transmitter signals | DL4000 |
| PoE logger with interchangeable smart probes | VDL200 |
Seacom Process Instruments supplies and supports Vaisala DL1000, DL1400, DL1016 and DL1416 temperature data loggers in Malaysia for pharmaceutical facilities, laboratories, hospitals, blood banks, warehouses, cold rooms, refrigerators, incubators and ultra-low-temperature freezers. We can also assist existing DL-series users with migration planning for the VDL200 platform.
Our team can assist with model and probe selection, monitoring-point planning, thermal-buffer selection, network connectivity, viewLinc system integration, installation, commissioning, alarm configuration, calibration planning and GxP validation documentation.
Contact Seacom with your temperature range, required accuracy, number of channels, probe length, door-contact requirement, sampling interval, network constraints and validation expectations. We can check whether a DL-series logger is still appropriate or prepare a suitable VDL200 configuration.