Vaisala VDL200 is an Ethernet-connected data logger for continuous monitoring systems.
It provides high accuracy measurements from up to 2 detachable humidity, temperature, and carbon dioxide probes.
Suitable applications include real-time measurements in environments where wired connections are preferred.
VDL200 is compatible with the Vaisala viewLinc Enterprise Server software.
Vaisala Official Distributor in Humidity, Dewpoint, Continuous Monitoring System (CMS) viewLinc (2015),
Temperature, CO2, Barometric Pressure, Moisture in Oil, Wind etc in Malaysia since 1990s
The Vaisala VDL200 data logger integrates Vaisala's advanced sensor technology with the viewLinc Continuous Monitoring System software, which ensures data integrity and compliance with global regulations in the life science industries. Designed for applications that prioritize communication performance, the VDL200 uses Power-over-Ethernet connectivity to streamline installation and facilitate configuration. With a single cable for power and data, the VDL200 is compatible with a range of Vaisala's high-performance, interchangeable probes. Equipped with probe inputs for monitoring temperature, relative humidity, and CO2 levels, VDL200 offers versatile, scalable monitoring across multiple applications. VDL200 can also connect to Vaisala Insight PC software to provide many field-service friendly features, including on-site calibration. The Vaisala VDL200 data logger can be used with our software to download, display, and analyze environmental data as well as provide tamper-proof electronic records that meet 21 CFR Part 11 requirements. The optional browser-based viewLinc system provides 24/7 multi-stage alarm notification, remote, real-time monitoring and gap-free data. Reports are customizable and can be exported to Excel. |
Download |
.
The Vaisala 2000 recorder combines internal temperature and RH sensors with an optional external channel for either current or voltage inputs for recording parameters such as differential pressure, CO2, level, particles, or conductivity. The Vaisala 2000 recorder can include a Boolean channel for door switches or alarm contacts.
The Vaisala 4000 Series of data recorders are designed to interface with a wide range of transducers, transmitters, and sensors with a DC voltage or 0 - 20 mA current loop output.
The Vaisala HMT140 wireless data logger is designed for humidity, temperature and analog signal monitoring in warehouses, freezer and cryogenic farms, laboratories, blood banks and many other life science applications
The Vaisala HMT140 incorporates Vaisala HUMICAP® technology to measure relative humidity and temperature accurately and reliably. The Vaisala HUMICAP sensor is resistant to dust and most chemicals. Alternatively, the Vaisala HMT140 can connect to Resistance Temperature Detectors (RTDs), Voltage, Current and Contact sensors, making the Vaisala HMT140 the most versatile Vaisala data logger for life science applications.
The Vaisala continuous monitoring system is ideal for both light and heavy industrial environments, as well as GxP-regulated applications, the system integrates a wide selection of data loggers, transmitters and Modbus devices to monitor several parameters: temperature, relative humidity, dew point temperature, CO2, differential pressure, door contacts, and more. The viewLinc software is backwards compatible and able to access data created with older versions of the software.
The DL1700 thermocouple data loggers provide accurate temperature data acquisition, remote alarming, and continuous monitoring.
The loggers are ideal for demanding environments that use extreme temperatures, from -240 °C to 1760 °C; applications such as liquid nitrogen (LN2), ovens, sterilization chambers and other extreme temperatures in laboratories and industrial environments.
The loggers connect to Vaisala's viewLinc software to provide historical and real-time data, remote alarming, and reporting in compliance with global regulations and standards.
The Vaisala OPC-DA Server software can be used to integrate Vaisala DL-series data loggers to non-Vaisala systems. If access to historical measurements is needed, the Vaisala OPC-UA Server can be used to integrate the viewLinc database with non-Vaisala systems.
Vaisala's multi-application temperature data logger monitors temperatures in up to four applications with one logger – ultra-low temperature freezers, freezer/refrigerators and incubators. A superior alternative to chart recorders and hard-wired systems.
Vaisala DL1000, DL1016, 1400, DL1416 is a high-accuracy temperature data logger. Ideal for ultra-low temperature freezers, fridges, cold rooms in regulated environments, the DL1000-1400 temperature logger provides stable, reliable measurements. With a measurement range from -90 °C to +70 °C and stable accuracy at ±0.10°C, the DL1000-1400 series can take up to four inputs for monitoring or mapping temperatures in that range. This series also offers an optional input for door monitoring
The DL-series temperature loggers connect to Vaisala's viewLinc software to provide historical and real-time data, remote alarming, and reporting in compliance with global regulations and standards. The Vaisala OPC-DA Server software can be used to integrate Vaisala DL-series data loggers to non-Vaisala systems. If access to historical measurements is needed, the Vaisala OPC-UA Server can be used to integrate the viewLinc database with non-Vaisala systems.
.
The Vaisala RFL100 Data Logger uses Vaisala’s proprietary VaiNet wireless technology. It can be used to monitor temperature (T), relative humidity (RH), and carbon dioxide level (CO2) in a wide range of environments. Suitable applications include warehouses, production areas, cleanrooms, laboratories, incubators, fridges, cold storage areas, and freezers down to −196 °C (approx. −320 °F).
The Vaisala 2000 recorder combines internal temperature and RH sensors with an optional external channel for either current or voltage inputs for recording parameters such as differential pressure, CO2, level, particles, or conductivity. The Vaisala 2000 recorder can include a Boolean channel for door switches or alarm contacts.
The DL1700 thermocouple data loggers provide accurate temperature data acquisition, remote alarming, and continuous monitoring.
The loggers are ideal for demanding environments that use extreme temperatures, from -240 °C to 1760 °C; applications such as liquid nitrogen (LN2), ovens, sterilization chambers and other extreme temperatures in laboratories and industrial environments.
The loggers connect to Vaisala's viewLinc software to provide historical and real-time data, remote alarming, and reporting in compliance with global regulations and standards.
The Vaisala OPC-DA Server software can be used to integrate Vaisala DL-series data loggers to non-Vaisala systems. If access to historical measurements is needed, the Vaisala OPC-UA Server can be used to integrate the viewLinc database with non-Vaisala systems.
The PDT101 differential pressure transmitter is designed for demanding cleanroom applications. The sensor integrates with the Vaisala viewLinc monitoring system to measure and monitor pressure differentials in regulated environments. Ideal for high performance cleanroom environments in the life science, semiconductor and electronics industries.
The Vaisala continuous monitoring system is ideal for both light and heavy industrial environments, as well as GxP-regulated applications, the system integrates a wide selection of data loggers, transmitters and Modbus devices to monitor several parameters: temperature, relative humidity, dew point temperature, CO2, differential pressure, door contacts, and more. The viewLinc software is backwards compatible and able to access data created with older versions of the software.
The Vaisala 4000 Series of data recorders are designed to interface with a wide range of transducers, transmitters, and sensors with a DC voltage or 0 - 20 mA current loop output.
Vaisala's multi-application temperature data logger monitors temperatures in up to four applications with one logger – ultra-low temperature freezers, freezer/refrigerators and incubators. A superior alternative to chart recorders and hard-wired systems.
Vaisala DL1000, DL1016, 1400, DL1416 is a high-accuracy temperature data logger. Ideal for ultra-low temperature freezers, fridges, cold rooms in regulated environments, the DL1000-1400 temperature logger provides stable, reliable measurements. With a measurement range from -90 °C to +70 °C and stable accuracy at ±0.10°C, the DL1000-1400 series can take up to four inputs for monitoring or mapping temperatures in that range. This series also offers an optional input for door monitoring
The DL-series temperature loggers connect to Vaisala's viewLinc software to provide historical and real-time data, remote alarming, and reporting in compliance with global regulations and standards. The Vaisala OPC-DA Server software can be used to integrate Vaisala DL-series data loggers to non-Vaisala systems. If access to historical measurements is needed, the Vaisala OPC-UA Server can be used to integrate the viewLinc database with non-Vaisala systems.
Vaisala CMS Industrial Cabinet CAB100 integrates Vaisala’s world-class instruments for monitoring differential pressure and other parameters into a simple, preconfigured instrument panel. In combination with the Vaisala viewLinc Enterprise Server Software, the cabinet provides pre-installed real-time monitoring of your critical environments.
The Vaisala HMT140 wireless data logger is designed for humidity, temperature and analog signal monitoring in warehouses, freezer and cryogenic farms, laboratories, blood banks and many other life science applications
The Vaisala HMT140 incorporates Vaisala HUMICAP® technology to measure relative humidity and temperature accurately and reliably. The Vaisala HUMICAP sensor is resistant to dust and most chemicals. Alternatively, the Vaisala HMT140 can connect to Resistance Temperature Detectors (RTDs), Voltage, Current and Contact sensors, making the Vaisala HMT140 the most versatile Vaisala data logger for life science applications.
Vaisala VDL200 is an Ethernet-connected data logger for continuous monitoring systems.
It provides high accuracy measurements from up to 2 detachable humidity, temperature, and carbon dioxide probes.
Suitable applications include real-time measurements in environments where wired connections are preferred.
VDL200 is compatible with the Vaisala viewLinc Enterprise Server software.