Vaisala viewLinc Continuous Monitoring System

Vaisala viewLinc Continuous Monitoring System

Vaisala Continuous Monitoring System

viewLinc Continuous Monitoring System for Critical Environments

The Vaisala viewLinc Continuous Monitoring System provides continuous measurement records, real-time trends, configurable alarms and secure reporting for temperature, relative humidity, carbon dioxide, differential pressure, door contacts and other critical parameters.

Continuous monitoring and alarming GxP data-integrity support Wired, PoE and VaiNet connectivity Scalable multi-site architecture
Independent environmental monitoring

Protect products, processes and controlled environments

viewLinc combines monitoring software, Vaisala data loggers, measurement probes, network devices and compatible Modbus instruments into one scalable environmental monitoring system.

Measurements are recorded autonomously at the monitoring location and transferred to the viewLinc Enterprise Server for centralised display, alarms, reports and audit review. This independent architecture can operate alongside a building-management or process-control system.

Continuous RecordsAutonomous measurement and local device memory help preserve environmental records.
Configurable AlarmsThreshold, device and communication alarms notify responsible personnel.
Secure ReportingHistorical, alarm and audit-trail reports support quality review and inspections.
Flexible ExpansionAdd monitoring points, locations and compatible devices as requirements grow.
System architecture

How the viewLinc monitoring system works

Each layer of the system has a defined role—from measurement at the monitored location to centralised alarm and report management.

01

Measure at the Monitoring Point

Vaisala data loggers and probes measure temperature, relative humidity, carbon dioxide and other parameters directly at rooms, chambers, refrigerators, freezers, warehouses and production areas.

Typical parameters Temperature and humidity Carbon dioxide Differential pressure
02

Record Data Locally

Compatible data loggers record measurements autonomously. Local device memory protects records during temporary network or server interruptions and transfers stored data after communication is restored.

Operational benefit Independent recording Network-interruption protection Automatic data transfer
03

Transfer Through the Facility Network

Devices can connect through Ethernet, Power over Ethernet and Vaisala VaiNet long-range wireless technology. The appropriate connection method is selected according to the site layout, infrastructure and monitoring requirements.

Connectivity VaiNet wireless Ethernet Power over Ethernet
04

Monitor, Alarm and Report

viewLinc Enterprise Server receives measurement data, displays real-time and historical trends, recognises alarm conditions and creates reports for operational and quality review.

Software functions Real-time trends Alarm management Scheduled reports
GxP and data-integrity support

Designed for secure monitoring records

viewLinc supports regulated monitoring workflows with controlled user access, audit trails, alarm acknowledgements, secure records and configurable reports. The system can support implementation aligned with requirements such as FDA 21 CFR Part 11 and EU Annex 11 when it is correctly configured, validated and operated within the organisation’s quality system.

  • User accounts, roles and authority levels
  • Audit trails for system events and configuration changes
  • Alarm acknowledgement and comment records
  • Historical, alarm and audit-trail reporting
  • Optional IQ/OQ protocols and GxP documentation
  • Calibration options traceable to recognised standards
Explore viewLinc compliance features →
Protected monitoring workflow Measure Record Alarm Acknowledge Report
System components

Build the system around each monitoring requirement

viewLinc supports different measurement and connectivity options, allowing each monitoring point to use a suitable logger, probe or transmitter.

viewLinc Enterprise Server

Central software for real-time monitoring, alarm management, trends, reports, audit trails and multi-site visibility.

View the viewLinc system →

RFL100 and AP10

VaiNet wireless data loggers and access points for long-range temperature, humidity and carbon-dioxide monitoring.

View RFL100 and AP10 →

VDL200

Power-over-Ethernet data logger for temperature, humidity, carbon dioxide, analog inputs and door-contact applications with suitable probes.

View Vaisala VDL200 →

CAB100 Cabinet

Preconfigured instrument cabinet for centralised integration of differential pressure, analog inputs and other measurements.

View Vaisala CAB100 →

PDT101

Differential-pressure transmitter for cleanrooms, laboratories and other pressure-controlled environments.

View Vaisala PDT101 →

Compatible Modbus Devices

Licensed Modbus-device support allows additional measurement parameters to be incorporated into the monitoring architecture.

Discuss device integration →
Alarm and reporting functions

Notify the right people and document the response

Alarm thresholds, delays, schedules and notification routes can be configured according to monitoring-point risk and operating procedures. Alarm acknowledgements and comments provide a record of the response.

Preconfigured and custom reports can be generated for environmental history, alarms and audit trails. Reports may also be scheduled for automatic delivery to selected users.

Monitoring applications

Where viewLinc is used

The system can support regulated, industrial and critical-storage environments requiring dependable environmental records and alarm notification.

Pharmaceutical and Biotechnology

Warehouses, production areas, cleanrooms, laboratories, stability chambers and controlled storage.

Explore viewLinc →

Hospitals and Healthcare

Pharmacies, blood banks, vaccine storage, tissue storage, refrigerators and freezers.

Explore viewLinc →

Cleanrooms and Laboratories

Temperature, humidity and differential-pressure monitoring in controlled environments.

View pressure monitoring →

Cold Rooms and Freezers

Continuous monitoring of temperature-sensitive medicines, samples and biological materials.

View wireless monitoring →

Semiconductor Manufacturing

Environmental monitoring for production, cleanroom and material-storage areas.

Discuss your application →

Data Centres

Independent monitoring of server rooms, data halls, equipment rooms and cooling infrastructure.

Read the data-centre guide →
Implementation and Lifecycle Support

viewLinc Project Support in Malaysia

Seacom provides technical assistance throughout the planning, implementation and operational lifecycle of the Vaisala viewLinc Continuous Monitoring System.

Requirement Review Review of the user requirement specification, monitored parameters and project objectives.
System Architecture Planning of the viewLinc server, network infrastructure, access points and monitoring devices.
Monitoring-Point Selection Selection of representative measuring locations in rooms, equipment and controlled-storage areas.
Installation Installation of data loggers, probes, access points and network components.
Commissioning Device configuration, communication checks, alarm testing and functional verification.
Validation Support IQ/OQ execution assistance and supporting documentation for regulated applications.
Calibration Planning Planned verification and calibration according to the monitoring-point requirements.
Lifecycle Support System expansion, device servicing, software review and ongoing technical assistance.
Vaisala viewLinc supplier in Malaysia

Plan a Reliable Continuous Monitoring System

Share your facility layout, monitored parameters, alarm requirements, regulatory needs and preferred network architecture. Seacom Process Instruments can assist from system selection through installation, commissioning, validation support and calibration planning.

Contact Seacom

For current system capabilities and technical information, refer to the official Vaisala viewLinc product information.

All comments

back to top