Vaisala Humidity Calibrator HMK15 makes calibration and spot checking of humidity probes and transmitters easy and reliable.
Vaisala Official Distributor in Humidity, Dewpoint, Continuous Monitoring System (CMS) viewLinc (2015),
Temperature, CO2, Barometric Pressure, Moisture in Oil, Wind etc in Malaysia since 1990s
It is essential that the functioning of an instrument is periodically checked against a reference Vaisala has developed the Vaisala humidity Calibrator HMK15 to make claibration and spot checking of humidity probes and transmitters easily and reliable.
|
Model | HMK15 | |
Accuracy (at 20ºC) of certified calibrated and ready dosed salt |
LiCl (11% rH): ±1.3% MgCl2 (33% rH): ±1.2% NaCl (75% rH): ±1.5% K2SO4 (97% rH): ±2.0% |
|
Included accessories |
|
Download |
.
Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMD110, HMW110, HMS110 series measure relative humidity and temperature in multiple HVAC applications.
The series includes transmitters for duct mounting HMD110, IP65-classified wall transmitters, and outdoor transmitters with integrated radiation shieldsHMS110.
Vaisala HMD110, HMW110, HMS110 series transmitters are equipped with trusted HUMICAP® 180R sensors. They are individually adjusted and delivered with a calibration certificate. The factory calibration is traceable to NIST.
Transmitters can be field-calibrated using either an HM70 Hand-Held Humidity and Temperature Meter, or a PC connection.
Sato Thermohygrograph NSII-Q, Sigma II, 7210-00, 7211-00
(as known as Sato Thermohygrograph SigmaII, Sato Thermohygrograph 7210-00, Sato Thermohygrograph 7211-00) comes with all transparent acryl-resin made case provides a full view of the chart paper without opening the case
Features:
* The required time cycle is selected by simply pushing the changeover switch
* Recording charts is made by non-dust paper and it is with holes for easy binding in a file .
Humidity and Temperature Probe HMP5
for high temperature humidity and temperature applications with exchangeable sensor
Vaisala HUMICAP® Humidity and Temperature Probe HMP5 is designed for high temperature applications such as baking ovens, pasta dryers, ceramics and industrial drying kilns where measurement performance and chemical tolerance are essential
HMP1 is part of the Indigo family and is compatible with Indigo500 and Indigo200 series transmitters. It can be used with Vaisala Insight PC software for data visualization, easy probe configuration, and field calibration.
Humidity and Temperature Probe HMP155
Superior Accuracy for Harshest Environments
Vaisala Humidity and Temperature Probe HMP155 provides reliable humidity and temperature measurement. It is designed especially for demanding outdoor applications.
The Vaisala HUMICAP® Humidity and Temperature Probe HMP9 is designed for easy installation in rapidly changing environments where a fast response time, measurement performance, and chemical tolerance are essential. The compact size enables installation even in tight spaces, with the probe head only 5 mm (0.2 in) in diameter.
The HMP9 complements the Indigo product family and is ideal for applications such as inlet monitoring in dryers, air handling units, data centers, test chambers, and other humidity measurement applications with temperatures under 120 °C (248 °F) that don’t involve high pressure. The HMP9 is compatible with Indigo500 and Indigo200 series transmitters and Insight PC Software.
Vaisala HUMICAP® Humidity and Temperature Probe HMP8 is designed for pressurized applications in compressed air systems, refrigerant dryers, and other pressurized industrial applications where easy insertion and removal of the probe and adjustable installation depth into the pipeline are needed.
The HMP8 is part of the Indigo product family and compatible with Indigo500 and Indigo200 series transmitters and free Insight PC Software.
Vaisala HMT360 humidity and temperature transmitter is designed for use in potentially explosive atmospheres. The electronics are designed so that the transmitter is intrinsically safe. The whole transmitter can be installed directly into an explosive area, even into areas classified as having a constant risk of explosion (Zone 0). HMT360 fulfils all requirements of current standards. The microprocessor-based HMT360 is easy to install, maintain and calibrate due to its modular structure. The interchangeable probes are easy to remove and enable on-site calibration. They make the HMT360 series versatile and ensure its suitability for almost any application
Also suitable for measuring water activity of Jet Fuel
Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300
Vaisala Indigo300 Transmitter is a host device for displaying measurement values from Vaisala Indigo-compatible probes and/or transmitting them to automation systems through analog signals.
The Vaisala HUMICAP® Digital Humidity Module HMM105 is an open frame module for integration into environmental chambers.
The modules provide an I2C output>for relative humidity (RH) or dew point (Td). The module consists of a detachable probe assembly – a probe head with M10x1 threads and a flex cable – and the module circuit board. The probe assembly is 30 cm in length.
The module incorporates the Vaisala HUMICAP® 180R sensor which ensures excellent measurement accuracy.
Humidity and Temperature Probe HMP4
for high pressure humidity and temperature applications with exchangeable sensor
Vaisala HUMICAP® Humidity and Temperature Probe HMP4 is designed for high-pressure applications such as compressed air systems in maritime, breathing air, and industrial applications, where measurement performance and chemical tolerance are essential.
HMP4 is part of the Indigo family and is compatible with Indigo500 and Indigo200 series transmitters. It can be used with Vaisala Insight PC software for data visualization, easy probe configuration, and field calibration.
Humidity and Temperature Probe HMP3
for general purpose humidity and temperature applications with exchangeable sensor
Vaisala HUMICAP® Humidity and Temperature Probe HMP3 is a general-purpose probe designed for processes with moderate humidity and temperature levels. The probe structure allows the sensor to be replaced in the field without tools, making it suitable for applications such as industrial HVAC systems, paint booths, cleanrooms, environmental chambers, and applications where periodic recalibration is not sufficient for maintenance.
HMP3 is part of the Indigo family and is compatible with Indigo500 and Indigo200 series transmitters. It can be used with Vaisala Insight PC software for data visualization, easy probe configuration, and field calibration.