    Watanabe Output Isolator TW-2X

Watanabe TW-2X Two-Output DC Signal Isolator

The Watanabe TW-2X converts one DC voltage or current input into two proportional DC outputs for measurement and control systems.

  • Two outputs for connecting compatible receiving instruments.
  • 24 V DC power supply.
  • Accuracy: ±0.1% of full scale.
  • Response time: 50 ms, from 0 to 90%.
  • Compact construction with integrated wiring terminals.

Need advice or a quotation?

Ask Seacom about specifications, availability and the right instrument for your application.

Watanabe TW-2X Two-Output DC Signal Isolator

The Watanabe TW-2X accepts a DC voltage or current signal and provides two proportional DC outputs. It is useful when one measurement signal needs to serve two receiving devices, such as a PLC and a recorder, subject to matching their signal and load requirements.

Powered by 24 V DC, the TW-2X combines the converter and terminal block in a compact unit for instrument-panel installations.

Key Features

  • One DC voltage or current input with two DC outputs.
  • Signal isolation and proportional conversion.
  • Accuracy of ±0.1% of full scale.
  • 50 ms response time from 0 to 90%.
  • Integrated terminal-block construction.

Technical Specifications

SpecificationTW-2X
Input DC voltage or DC current
Output Two outputs; DC voltage/current according to ordering specification
Power supply 24 V DC
Accuracy ±0.1% FS
Response time 50 ms, 0–90%
Dielectric strength 2000 V AC
Dimensions 98 × 48 × 41 mm (H × W × D)
Weight Approximately 130 g
Operating temperature −5 to +50°C
Operating humidity 90% RH or below

FS means full scale. Specify the input range and both output ranges when ordering. Check the applicable load limits and wiring arrangement for the complete model code.

Using One Signal with Two Instruments

A typical arrangement sends one output to the control system and the other to a display or recording device. Both outputs represent the same measured input; this is not a two-input measurement instrument.

ConnectionApplication example
Input DC measurement signal from a compatible transmitter or signal source.
Output 1 Signal to a PLC or controller for process control.
Output 2 Signal to a recorder or indicator for monitoring.

Confirm the required isolation between circuits against the manufacturer’s connection diagram, especially when the receiving devices have different grounding arrangements.

Original Specification Reference — Part 1

Watanabe TW-2X two-output isolator original specification reference part 1

Original Specification Reference — Part 2

Watanabe TW-2X two-output isolator original specification reference part 2

Selection and Ordering

  • Input signal: provide the signal type, minimum and maximum values, and source instrument.
  • Both outputs: identify the signal range and input requirements of each receiving device.
  • Power: confirm that a suitable 24 V DC supply is available.
  • Connections: confirm the required terminal or connector arrangement.
  • Existing installations: include the complete model code and photographs of the label and wiring terminals.

Related Signal Isolators

For applications requiring one output, compare the Watanabe TZ-1XA and TZ-5XA DC signal isolators.

Need Help Selecting a Two-Output Isolator?

Contact Seacom with your input signal, both required outputs and connected equipment. We can help check the configuration for your measurement and control application.

16 other products in the same category:

Vaisala DMT152 - Discontinued
  • Out-of-Stock

The Vaisala DMT152 provides accurate dew-point measurement down to −80 °C Td/f for ultra-dry industrial and OEM applications. This model is discontinued and has been replaced by the Vaisala DMT153.

  • Calibrated dew-point range from −80 to −20 °C Td/f
  • Accuracy up to ±2 °C Td/f
  • Operating pressure up to 50 bar
  • Analog outputs and RS-485 communication
  • DRYCAP® sensor resistant to condensation and contamination
  • Use DMT153 for new projects
Tokico electronic oil flowmeter FRL
  • Out-of-Stock

The Tokico FRL and FRY are high-accuracy electronic positive displacement flow meters for diesel, kerosene, fuel oil, heavy oil, lubricating oil, crude palm oil and other compatible industrial liquids.

The Tokico 75 Series combines direct volumetric measurement with a large LCD display and optional pulse, analogue and alarm outputs for local indication and integration with industrial monitoring systems.

Vaisala MMT330 Discontinued | MMP8 Replacement | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala MMT330 Series provided continuous measurement of moisture and temperature in transformer oil, lubrication oil, hydraulic fluid and other liquid hydrocarbons.

  • Discontinued series; not recommended for new installations
  • Legacy MMT332, MMT337 and MMT338 probe configurations
  • Measures water activity, relative saturation, temperature and calculated ppm
  • Graphical display, data logging and versatile analogue or digital outputs
  • Used for oil-condition monitoring, dryer control and free-water risk detection
  • Use Vaisala MMP8 with an Indigo transmitter for new installations
TOKICO PFA Ultrasonic Vortex Flowmeter for Chemicals and Ultrapure Water
  • Out-of-Stock

The TOKICO PFA ultrasonic vortex flowmeter measures compatible chemicals, corrosive liquids and ultrapure water using PFA liquid-contacting construction.

  • No moving parts.
  • Connection sizes: 3/8, 1/2, 3/4 and 1 inch.
  • Fluid temperature range: 0–100°C.
  • Flow range and pressure rating depend on size and operating conditions.
  • Local display with output functions according to configuration.
MSR Gas Detection and Alarm System
  • Out-of-Stock

MSR gas detection systems continuously monitor combustible, toxic and refrigerant gases, generate local or central alarms and interface with ventilation, shutdown and building-management systems.

  • Gas-specific fixed detectors for commercial and industrial applications
  • Compact controllers for small systems and networked controllers for larger sites
  • Analogue, relay, RS-485 and Modbus integration options
  • Local displays, warning indicators, sounders and beacons
  • Solutions for general areas and certified hazardous areas
  • Applications include refrigeration plants, laboratories, garages and process facilities
Needle Probe for Food BC Series
  • Out-of-Stock

The Anritsu BC Series measures internal temperature in food, liquids and semi-solid materials. Its needle design reaches the measurement point inside the sample.

  • Designed for food core-temperature measurement.
  • IPX5 construction allows washing under running water.
  • Type K and Type E thermocouple options.
  • Choice of probe diameter, length, protective-pipe coating and connector.
Vaisala DPT146 Dew Point Transmitter - Discontinued
  • Out-of-Stock

The Vaisala DPT146 combines dew-point and process-pressure measurement in one compact transmitter for compressed-air systems. This model is discontinued and should not be selected for new projects.

  • Dew-point measurement from −70 to +30 °C Td
  • Absolute-pressure measurement from 1 to 12 bar
  • Pressure-compensated dew point and ppm calculation
  • Analog outputs and RS-485 with Modbus RTU
  • Contact Seacom for existing-unit support and replacement assessment
Tokico Flow Meter Malaysia FGB FRO FRP | Seacom
  • Out-of-Stock

The Tokico FGB, FRO and FRP are high-accuracy mechanical positive displacement flow meters for measuring diesel, kerosene, fuel oil, heavy oil, crude palm oil and other compatible industrial liquids.

Available in sizes from 15 to 100 mm, these durable Tokico flow meters provide direct mechanical totalisation, accuracy within ±0.5% and flow capacities ranging from small-volume fuel consumption to large oil-transfer applications.

Vaisala HMT120 and HMT130 Transmitters (Are Being replaced by Origo10) | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala HMT120 and HMT130 provide accurate, stable humidity and temperature measurement for cleanrooms, laboratories, data centres and demanding HVAC applications.

Product transition: HMT120/HMT130 are expected to be phased out. For new projects, the Vaisala Origo10 is the recommended replacement platform.

  • Humidity accuracy up to ±1.5% RH
  • HMT120 loop-powered 4–20 mA output
  • HMT130 voltage outputs, RS-485 and relay
  • Interchangeable fixed or remote measurement probe
  • Origo10 recommended for new installations
MSR ADT-23 Combustible Gas Transmitter
  • Out-of-Stock

The MSR PolyGard ADT-23 is a fixed transmitter for continuous monitoring of combustible gases and vapours in ambient air.

  • Digital processing with temperature compensation
  • Gas- and range-specific sensor configuration
  • Selectable (0) 4–20 mA or (0) 2–10 V DC analogue output
  • RS-485 interface for compatible communication protocols
  • Optional two relays with adjustable switching thresholds
  • Calibration routine with controlled access
Cabinet for Continuous Monitoring System (CMS)
  • Out-of-Stock

The Vaisala CAB100 centralises differential-pressure transmitters, analog inputs and interface components for cleanroom and industrial monitoring with the viewLinc Continuous Monitoring System.

  • Preconfigured cabinet for viewLinc monitoring systems
  • CAB100A and higher-capacity CAB100B models
  • Differential pressure, analog input and hazardous-area options
  • IP54 or IP66 enclosure protection, depending on model
Vaisala Origo10
  • Out-of-Stock

The Vaisala Origo10 Series comprises modular HVAC transmitters with interchangeable probes for humidity, temperature, CO2 and dew-point measurement.

Available with analog, Modbus RTU and BACnet MS/TP outputs, wall or duct mounting, an optional display and an IP65-rated enclosure.

Waterproof Infrared Thermometer SK-8950
  • Out-of-Stock

The Sato SK-8950 measures surface temperature without contact, with a circular laser marker and adjustable emissivity to suit different materials.

  • Measuring range: −60 to 550°C.
  • Approximately 12:1 distance-to-spot ratio.
  • Adjustable emissivity from 0.10 to 1.00.
  • High/low alarms and MAX, MIN, AVG and DIF display.
  • Backlit display and continuous measurement mode.
  • IP54 protection against dust and water splashes.

For industrial surface measurements; not intended for clinical body-temperature measurement.

CO₂ Probe GMP252
  • Out-of-Stock

The Vaisala GMP252 is an intelligent standalone probe for stable ppm-level carbon-dioxide measurement in demanding HVAC, refrigeration, agriculture and industrial applications.

  • CO₂ measurement range from 0 to 10,000 ppm
  • Measurement up to 30,000 ppm with reduced accuracy
  • Accuracy of ±40 ppm from 0 to 3000 ppm
  • Compensation for temperature, pressure, humidity and oxygen
  • Heated sensor head helps prevent condensation
  • 0–20 mA, 4–20 mA, 0–5 V, 0–10 V and RS-485 output options
  • Standalone Modbus RTU operation or connection to an Indigo transmitter
  • Compatible with Vaisala Indigo80 and Insight PC software
FUJIFILM Prescale Pressure Film | Seacom
  • Out-of-Stock

FUJIFILM Prescale reveals contact pressure and pressure distribution through changes in red colour density. Place the film between contacting surfaces to identify uneven loading and compare contact patterns.

  • Nine standard grades covering 0.006 to 300 MPa
  • Two-sheet and mono-sheet types, depending on the grade
  • For pressure checks on rollers, flanges, gaskets, presses and contact surfaces
  • Choose the grade according to pressure, temperature and humidity conditions