Isuzu Thermohygrograph TH27R Isuzu Thermohygrograph TH27R

Isuzu TH27R Quartz Thermohygrograph – Discontinued

The Isuzu TH27R paper temperature and humidity recorder has been discontinued and is no longer recommended for new installations. Seacom continues to support existing instruments with selected chart papers and recording pens.

  • Legacy temperature range from −20 to +50 °C
  • Relative-humidity range from 0 to 100 %RH
  • Quartz-driven cylindrical paper-chart recorder
  • Replacement TH27R chart papers and cartridge pens remain available
  • Existing recorder and chart details must be confirmed before ordering
  • Closest current substitute: Sato Sigma II NSII-Q thermohygrograph

The Isuzu TH27R paper thermohygrograph is discontinued and should not be specified for new installations. Seacom continues to help existing users identify selected chart papers and recording pens.

  • Legacy measuring range: −20 to +50 °C and 0 to 100 %RH
  • Quartz-driven cylindrical temperature and humidity chart recorder
  • Existing recorder and consumable references must be checked before ordering
  • Selected TH27R chart papers and pens remain available, subject to confirmation
  • Closest current paper-recorder option: Sato Sigma II NSII-Q
  • Malaysia-based support for local and international enquiries

Discontinued thermohygrograph support

Isuzu TH27R Discontinued — Consumables and Replacement Guidance

The complete Isuzu TH27R recorder is discontinued. Keep an existing unit in service only while it remains suitable and serviceable. Seacom can check selected TH27R chart papers and recording pens against the recorder and existing consumable details.

For a new paper temperature-and-humidity recorder, consider the current Sato Sigma II NSII-Q. It performs the same basic recording function, but it is not a direct drop-in replacement and uses different chart papers and pens.

View the Sato Sigma II NSII-Q →

About the Isuzu TH27R Thermohygrograph

The Isuzu TH27R records temperature and relative humidity continuously on a cylindrical paper chart. It has been used in warehouses, laboratories, production areas, museums, archives and other locations where staff need a visible local record without software or network infrastructure.

This page is retained to help existing TH27R owners identify their instrument, find compatible consumables and compare a current replacement. It should not be used to specify the discontinued recorder for a new project.

Legacy Isuzu TH27R Specifications

Product status Discontinued
Temperature range −20 to +50 °C
Temperature accuracy Approximately ±1 °C
Relative-humidity range 0 to 100 %RH
Humidity accuracy Approximately ±3 %RH under specified conditions
Minimum chart graduation 1 °C and 1 %RH
Temperature sensor Bimetallic strip
Humidity sensor Human-hair bundle
Recording mechanism Quartz-driven cylindrical chart
Legacy recording periods 1, 7, 31, 62, 93, 183 or 365 days, depending on chart and recorder setting

Compatibility warning: similar-looking charts can have different time scales, temperature ranges, centre holes or printed arcs. Pens can also differ in arm fit and tip position. Do not order by appearance alone.

Isuzu TH27R Chart Paper and Recording Pens

When requesting consumables, provide as much of the following information as possible:

  • Recorder model and a clear photograph of the nameplate
  • Part number printed on the existing chart paper
  • Temperature and humidity scales printed on the chart
  • Recording period, such as 1, 7, 31 or 62 days
  • Photographs of the installed pens and recording arms
  • Required quantity and destination country

Supply remains subject to compatibility and stock confirmation. A chart or pen should not be assumed compatible merely because it fits another cylindrical recorder.

Isuzu TH27R or Sato Sigma II NSII-Q?

Selection pointIsuzu TH27RSato Sigma II NSII-Q
Product status Discontinued; support for existing units only Current paper thermohygrograph for new enquiries
Temperature range −20 to +50 °C 7210-00: −15 to +40 °C
7211-00: −10 to +50 °C
Humidity range 0 to 100 %RH 0 to 100 %RH, non-condensing
Chart periods 1, 7, 31, 62, 93, 183 or 365 days, depending on configuration Selectable 1, 7 or 32 days
Recording method Cylindrical paper chart with two pens Cylindrical paper chart with two pens
Power Battery-powered quartz mechanism Two C-size batteries
Chart compatibility Uses TH27R-specific charts Uses model- and period-specific Sato 7210/7211 charts
Recommended direction Maintain only while the installed recorder remains serviceable Evaluate for new paper-recorder requirements

The Sato Sigma II does not reproduce every TH27R chart period or the full legacy temperature span. Review the operating range, chart interval, mounting space and documentation procedure before changing recorder.

See Sato Sigma II models, specifications and chart references →

Choosing the Right Replacement Approach

Keep a paper recordEvaluate the Sato Sigma II when staff still need a visible chart at the monitoring location.
Move to electronic recordsConsider a temperature and humidity data logger when downloadable readings and trend analysis are required.
Add remote alarmsConsider a central monitoring system for multiple locations, alarm notifications, historical records and reporting.

Isuzu TH27R support and Sato replacement selection

Ask Seacom About TH27R Consumables or a Replacement Recorder

Seacom Process Instruments is based in Malaysia and welcomes local and international enquiries. For an existing TH27R, send the recorder nameplate, chart reference, printed range, recording period and photographs of the installed pens. For a new recorder, include the required temperature range, chart period, application and destination country.

We will check the suitable consumable or replacement direction and confirm availability, compatibility and delivery arrangements with the quotation.

Download


Specific References

You Might Also Like

.

12 other products in the same category:

.

back to top