DeltaTrak in-transit temperature loggers and recorders document temperature conditions during shipment.
Choose a transit temperature logger or recorder to document conditions during shipment. The DeltaTrak range below offers two record formats: a physical chart from the 16000 Series, or electronic reports from the FlashLink Mini PDF.
| Selection point | 16000 Series | FlashLink Mini PDF 31010 |
|---|---|---|
| Instrument type | Disposable temperature chart recorder | Single-use electronic temperature logger |
| Record format | Paper strip chart | PDF and CSV via USB |
| Recording period | 5–90 days, depending on model | Up to 85 days |
| Temperature coverage | Three ranges; see model table below | −40 to 60°C |
| Receiving workflow | Retrieve and retain the chart | Download and save electronic files |
The DeltaTrak 16000 Series produces a paper record of temperature conditions during transport and storage. These disposable strip chart recorders are used with temperature-sensitive shipments where the receiver needs a physical record to review and retain.
Select the recorder by both journey duration and temperature range. Model 16000 is the 5-day standard-range version; the wider series includes longer recording periods and high- and low-range options.
| Duration | Standard range −29 to 38°C | High range 0 to 65°C | Low range −40 to 27°C |
|---|---|---|---|
| 5 days | 16000 | 16002 | 16004 |
| 10 days | 16100 | 16102 | 16104 |
| 20 days | 16200 | 16202 | 16203 |
| 30 days | 16300 | 16302 | — |
| 40 days | 16350 | — | — |
| 60 days | 16400 | 16402 | 16403 |
| 90 days | 16500 | 16502 | — |
— indicates that no model is listed for that combination. Confirm availability of the required model when ordering.
| Specification | Details |
|---|---|
| Published temperature accuracy | ±2°F (±1°C) or better |
| Sensor | Bimetal coil |
| Chart | Pressure-sensitive strip, 36 inches (91.4 cm), dual °F/°C scale |
| Drive | Solid-state quartz motor |
| Clock accuracy | Average ±20 seconds per month |
| Battery type | Standard: AA carbon zinc; high range: AA alkaline; low range: AA lithium |
| Published shelf life | 3 years |
| Dimensions | 5.5 × 4 × 2.5 inches (L × W × H) |
| Weight | 198 g |
The FlashLink Mini PDF 31010 suits shipments requiring electronic records. Its built-in USB connection provides reports without installing dedicated logger software.
| Specification | FlashLink Mini PDF 31010 |
|---|---|
| Sampling interval | 10 minutes |
| Memory | 12,288 readings |
| Start delay | 30 minutes |
| Standard alarm configuration | No alarms; confirm any required alarm configuration before ordering |
| Protection | IP54 with silicone cap fitted |
| Published shelf life | 18 months |
Specify the recipient’s report requirements and computer connection when selecting this option. Confirm the supplied configuration before dispatch.
| Model | Alarm configuration | Logging interval | Data capacity | Maximum trip duration |
|---|---|---|---|---|
| 31010 | No alarms | 10 minutes | 12,288 readings | 85 days |
| 31010-25 | Low alarm: 7.2°C (45°F) | 10 minutes | 12,288 readings | 85 days |
| 31010-26 | Low alarm: 5.0°C (41°F) | 10 minutes | 12,288 readings | 85 days |
All three models provide °C/°F reports. Select the complete model code for the required alarm setting and confirm availability when ordering.
Contact Seacom with your shipment temperature range, expected journey duration, quantity and preferred record format. For repeat orders, include the existing logger or recorder model number so we can check the appropriate option.