    Watanabe Output Isolator TW-2X

Watanabe TW-2X Two-Output DC Signal Isolator

The Watanabe TW-2X converts one DC voltage or current input into two proportional DC outputs for measurement and control systems.

  • Two outputs for connecting compatible receiving instruments.
  • 24 V DC power supply.
  • Accuracy: ±0.1% of full scale.
  • Response time: 50 ms, from 0 to 90%.
  • Compact construction with integrated wiring terminals.

Need advice or a quotation?

Ask Seacom about specifications, availability and the right instrument for your application.

Watanabe TW-2X Two-Output DC Signal Isolator

The Watanabe TW-2X accepts a DC voltage or current signal and provides two proportional DC outputs. It is useful when one measurement signal needs to serve two receiving devices, such as a PLC and a recorder, subject to matching their signal and load requirements.

Powered by 24 V DC, the TW-2X combines the converter and terminal block in a compact unit for instrument-panel installations.

Key Features

  • One DC voltage or current input with two DC outputs.
  • Signal isolation and proportional conversion.
  • Accuracy of ±0.1% of full scale.
  • 50 ms response time from 0 to 90%.
  • Integrated terminal-block construction.

Technical Specifications

SpecificationTW-2X
Input DC voltage or DC current
Output Two outputs; DC voltage/current according to ordering specification
Power supply 24 V DC
Accuracy ±0.1% FS
Response time 50 ms, 0–90%
Dielectric strength 2000 V AC
Dimensions 98 × 48 × 41 mm (H × W × D)
Weight Approximately 130 g
Operating temperature −5 to +50°C
Operating humidity 90% RH or below

FS means full scale. Specify the input range and both output ranges when ordering. Check the applicable load limits and wiring arrangement for the complete model code.

Using One Signal with Two Instruments

A typical arrangement sends one output to the control system and the other to a display or recording device. Both outputs represent the same measured input; this is not a two-input measurement instrument.

ConnectionApplication example
Input DC measurement signal from a compatible transmitter or signal source.
Output 1 Signal to a PLC or controller for process control.
Output 2 Signal to a recorder or indicator for monitoring.

Confirm the required isolation between circuits against the manufacturer’s connection diagram, especially when the receiving devices have different grounding arrangements.

Original Specification Reference — Part 1

Watanabe TW-2X two-output isolator original specification reference part 1

Original Specification Reference — Part 2

Watanabe TW-2X two-output isolator original specification reference part 2

Selection and Ordering

  • Input signal: provide the signal type, minimum and maximum values, and source instrument.
  • Both outputs: identify the signal range and input requirements of each receiving device.
  • Power: confirm that a suitable 24 V DC supply is available.
  • Connections: confirm the required terminal or connector arrangement.
  • Existing installations: include the complete model code and photographs of the label and wiring terminals.

Related Signal Isolators

For applications requiring one output, compare the Watanabe TZ-1XA and TZ-5XA DC signal isolators.

Need Help Selecting a Two-Output Isolator?

Contact Seacom with your input signal, both required outputs and connected equipment. We can help check the configuration for your measurement and control application.

16 other products in the same category:

Sato SK-RHC Temperature & Humidity Transmitter | Seacom
  • Out-of-Stock

The Sato SK-RHC Series measures temperature and humidity with a local display and output for compatible monitoring equipment.

  • Voltage, 4–20 mA or RS-485 versions selected when ordering.
  • Plug-in, remote and miniature flexible probe options.
  • Relay alarm with an upper or lower threshold for each parameter.
  • Selectable 1-second or 10-second refresh interval.
  • Probe purchased separately; measurement range and accuracy depend on the probe.
Thermocouple Data Loggers DL1700 (CMS, FDA Approved)
  • Out-of-Stock

The Vaisala DL1700 is a four-channel thermocouple data logger for continuous monitoring and validation work at extreme temperatures.

  • Overall application range from −240 to +1760 °C, depending on thermocouple type
  • Accepts J, K, T, E, R and S thermocouples
  • Four thermocouple inputs plus an internal cold-junction reference
  • Works with Vaisala viewLinc for monitoring, alarms and compliant reporting
Dickson Chart Paper
  • Out-of-Stock

Dickson chart paper and replacement recorder pens for compatible temperature, humidity and pressure chart recorders.

  • 3-inch, 4-inch, 6-inch and 8-inch circular chart paper
  • Chart options for different measurement ranges and recording periods
  • Chart paper supplied in packs of 60 sheets
  • Red, blue and combined replacement pen packs
  • Selection assistance using your recorder model and existing part number

Send us a photograph of your current chart or pen packaging to help identify the correct replacement.

Sato Chart Paper
  • Out-of-Stock

Sato chart paper and replacement cartridge pens for Sigma II thermohygrographs and compatible Sato recording instruments.

  • 1-day, 7-day and 32-day charts for selected Sigma II models
  • Chart options for −15 to 40°C and −10 to 50°C instruments
  • Violet and red recording pens, individually or in 12-piece packs
  • Selection assistance using your recorder model and existing chart or pen reference
Flat Leaf Probe ST / STN Series
  • Out-of-Stock

Anritsu ST and STN flat leaf temperature probes feature thin, flexible sensing tapes for attachment to measurement surfaces.

  • ST probe assemblies and STN replaceable sensing tapes
  • Type K and Type E options, depending on configuration
  • Selected versions rated up to 400°C; limits vary by model
  • Choice of tape configurations, lengths and instrument connections
  • Selection assistance for complete probes and replacement tapes
Dickson Touch Screen Data Logger TWP
  • Out-of-Stock

The DicksonOne TWP provides local touchscreen viewing and cloud-connected monitoring of temperature, relative humidity or differential pressure. Its replaceable sensor system simplifies calibration and supports different monitoring applications using the same logger platform.

  • Large 8-inch LCD touchscreen
  • WiFi, Ethernet and Power over Ethernet connectivity
  • Approximately 1,000,000 sample-point backup capacity
  • Up to 70 hours of rechargeable battery backup
  • Replaceable temperature, humidity, thermocouple, RTD and differential-pressure sensors
  • Phone, text and email alarms through a DicksonOne subscription
Long Range Wireless Data Logger (CMS, FDA Approved) RFL100
  • Out-of-Stock

The Vaisala RFL100 uses secure, long-range VaiNet wireless technology to monitor temperature, relative humidity and carbon dioxide with the AP10 Access Point and viewLinc Continuous Monitoring System.

  • At least 50 m typical indoor wireless range
  • Up to 32 RFL100 data loggers per AP10
  • 30 days of local measurement memory
  • Approximately 18 months of battery operation for temperature and humidity monitoring
MSR Gas Detection and Alarm System
  • Out-of-Stock

MSR gas detection systems continuously monitor combustible, toxic and refrigerant gases, generate local or central alarms and interface with ventilation, shutdown and building-management systems.

  • Gas-specific fixed detectors for commercial and industrial applications
  • Compact controllers for small systems and networked controllers for larger sites
  • Analogue, relay, RS-485 and Modbus integration options
  • Local displays, warning indicators, sounders and beacons
  • Solutions for general areas and certified hazardous areas
  • Applications include refrigeration plants, laboratories, garages and process facilities
Anritsu AP-400 & AP-450 Handheld Thermo Printer
  • Out-of-Stock

The Anritsu AP-400 Series combines a high-accuracy thermocouple thermometer with a built-in thermal printer. Measurements can be printed immediately, printed automatically at selected intervals or stored and printed later.

  • Single-channel handheld thermometer with built-in printer
  • Manual, interval and sequential-number printing
  • Stores up to 100 measurements for batch printing
  • AP-400 supports Type E or K with an ASP connector
  • AP-450 supports Type E, K, J, T or R with an ANP connector
  • Thermocouple type is selected when ordering and is not switchable
  • Powered by four AA batteries or an optional AC adaptor

Ask Seacom about the AP-400 Series

Vaisala HMT120 and HMT130 Transmitters (Are Being replaced by Origo10) | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala HMT120 and HMT130 provide accurate, stable humidity and temperature measurement for cleanrooms, laboratories, data centres and demanding HVAC applications.

Product transition: HMT120/HMT130 are expected to be phased out. For new projects, the Vaisala Origo10 is the recommended replacement platform.

  • Humidity accuracy up to ±1.5% RH
  • HMT120 loop-powered 4–20 mA output
  • HMT130 voltage outputs, RS-485 and relay
  • Interchangeable fixed or remote measurement probe
  • Origo10 recommended for new installations
Isuzu Thermohygrograph TH27R
  • Out-of-Stock

The Isuzu TH27R paper temperature and humidity recorder has been discontinued and is no longer recommended for new installations. Seacom continues to support existing instruments with selected chart papers and recording pens.

  • Legacy temperature range from −20 to +50 °C
  • Relative-humidity range from 0 to 100 %RH
  • Quartz-driven cylindrical paper-chart recorder
  • Replacement TH27R chart papers and cartridge pens remain available
  • Existing recorder and chart details must be confirmed before ordering
  • Closest current substitute: Sato Sigma II NSII-Q thermohygrograph
Vaisala HMP110
  • Out-of-Stock

The Vaisala HMP110 is a high-accuracy humidity and temperature probe designed for demanding equipment integration, environmental chambers, data loggers, incubators and controlled-environment applications.

It provides ±1.5% RH accuracy, a 0–100% RH range, −40 °C to +80 °C temperature measurement, a chemically resistant HUMICAP 180R sensor and analog or Modbus RTU output options.

Hydrogen Peroxide H2O2, Humidity, And Temperature Probe HPP270
  • Out-of-Stock

The Vaisala HPP270 Series provides stable, repeatable measurement for demanding vaporized hydrogen peroxide bio-decontamination processes.

  • HPP271 measures vaporized H₂O₂ concentration
  • HPP272 adds relative saturation, relative humidity and temperature
  • H₂O₂ measurement range from 0 to 2000 ppm
  • Accuracy of ±10 ppm or 5% of reading, whichever is greater
  • Two 4–20 mA outputs or RS-485 with Modbus RTU
  • IP65 stainless-steel construction with Vaisala PEROXCAP® technology
  • Compatible with Vaisala Indigo transmitters and Indigo80
Anritsu BS Needle Temperature Probes | Seacom
  • Out-of-Stock

The Anritsu BS Series needle temperature probes measure internal temperature in liquids and semi-solid materials.

  • Type K and Type E thermocouple options.
  • Probe diameters from 0.9 mm to 5.0 mm, depending on the model.
  • Temperature ranges from −200°C up to 200°C, 300°C or 500°C, depending on the model.
  • Different insertion lengths, cables and connectors to suit the measurement task.
Low Temperature Probe BR Series
  • Out-of-Stock

The Anritsu BR Series measures temperature inside freezers, refrigerators, incubators and drying ovens. Select the probe configuration to suit your measurement location and compatible instrument.

  • Published model examples cover −100 to 200°C.
  • Type K and Type E thermocouple options.
  • Suitable for temperature checks and recording with a compatible instrument.
  • Confirm the probe, cable and connector specifications when ordering.
Ryutai Kogyo PGH Purge Flowmeter for Small Flow Rates
  • Out-of-Stock

Ryutai Kogyo PGH, GPB, GPC and AMF purge and panel flowmeters provide local flow indication for equipment and test systems.

  • PGH: compact glass tube meter for small flows.
  • GPB and GPC: glass tube panel meters with different flow capacities.
  • AMF: lightweight acrylic tube panel meter.
  • Choose the series, calibrated range and configuration to match the application.