Cart
Custom content

This is custom content

List of products by brand Vaisala

Authorised Vaisala Distributor in Malaysia

Seacom is an authorised Vaisala distributor in Malaysia for industrial measurement instruments and continuous monitoring systems. We supply humidity and temperature sensors, dew point meters and transmitters, CO₂ instruments, pressure instruments, moisture-in-oil probes, biogas instruments, weather and wind sensors and continuous monitoring systems related products.

Choosing an instrument starts with understanding the application. Apart from the measuring range, we need to consider the operating conditions, installation and connection to your existing system. Our team can help you check these details and select a suitable model.

If you are replacing an existing instrument, send us a clear photo of the model label and the complete order code. For a new installation, share your application or project specification so we can review the requirements with you.

Our Vaisala Range and Local Support

We support customers across Malaysia in pharmaceutical manufacturing, semiconductor production, battery manufacturing, data centres, HVAC and general industry. Some enquiries involve a single replacement probe; others involve instruments and monitoring points for a complete facility. In either case, the selection should match the actual site requirements.

  • settings_input_component Industrial transmitters and probes Measure humidity, temperature, dew point, CO₂ and pressure at the required point, with suitable outputs to the control or monitoring system.
  • work Portable measurement instruments Carry out checks at different locations during commissioning, maintenance and troubleshooting.
  • storage Continuous Monitoring Systems Record conditions, manage alarms and review historical data using Vaisala viewLinc.
  • domain Controlled-environment monitoring Monitor cleanrooms, laboratories, warehouses, refrigerators and freezers according to the conditions required.
  • ac_unit HVAC and building measurement Provide humidity, temperature, CO₂ and differential-pressure readings for room and air-handling control.
  • invert_colors Moisture-in-oil measurement Measure dissolved moisture and temperature in compatible lubrication, hydraulic and transformer oils.
  • nature Biogas and biomethane measurement Measure methane, CO₂ and humidity in suitable raw-biogas and upgrading applications.
  • wb_sunny Weather and wind measurement Measure outdoor conditions with weather transmitters and ultrasonic wind sensors suited to the installation.

Vaisala Products and Instrument Families

The categories below cover our main Vaisala instruments. Click the heading to view the products, or send us your requirements if you need help comparing the models.

Vaisala humidity sensor and transmitter Malaysia
Humidity and temperature

Humidity Sensors and Transmitters

For room, duct, cleanroom and process measurement, select Vaisala humidity and temperature transmitters or humidity probes according to the conditions at the sensing point. Check the temperature range, expected humidity, mounting arrangement and signal required by the receiving system.

Product families: HMP, HMD, HMW and XMP instruments, Origo10 transmitters and compatible Vaisala Indigo instruments.

View humidity instruments →
Vaisala dew point meter and transmitter Malaysia
Dew point

Dew Point Meters and Transmitters

For compressed air, dryers, dry rooms and process gases, the required dew point is an important starting point. We also need to check the line pressure and sampling arrangement. Use a fixed transmitter for continuous measurement or a portable meter for checks at several points.

Product families: DMP probes and DMT transmitters, with the model selected for the measuring range and installation conditions.

View dew point instruments →
Vaisala viewLinc Continuous Monitoring System Malaysia
Continuous monitoring

Vaisala viewLinc Continuous Monitoring System

Vaisala viewLinc brings readings, alarms and historical records into one monitoring system. For GxP applications, involve QA when defining the records, access permissions and qualification requirements. These should be agreed as part of the system scope.

System components: viewLinc software, RFL100 loggers, AP10 access points, VDL200 PoE loggers and CAB100 cabinets, selected according to the monitoring points and connections required.

Explore viewLinc CMS →
Vaisala Indigo80 portable humidity dew point and carbon dioxide meter
Portable measurement

Vaisala Portable Measurement Instruments

A portable instrument is useful for commissioning, maintenance checks and investigating unusual readings. The probe and accessories are as important as the handheld unit, particularly when measuring compressed air or taking readings at difficult locations.

Portable options: Indigo80 with compatible humidity, dew point or CO₂ probes. For an existing meter, provide the instrument and probe model numbers so compatibility can be checked.

View portable instruments →
Vaisala carbon dioxide sensor and transmitter Malaysia
Gas measurement

CO₂, Hydrogen Peroxide and Biogas Measurement

Ventilation systems, incubators, bio-decontamination equipment and biogas processes require different gas measurements. Confirm the gas, concentration range and operating conditions before selecting the probe.

Product families: GMP CO₂ probes, HPP hydrogen peroxide probes and MGP biogas probes. The parameters measured depend on the selected model.

View Vaisala gas instruments →
Vaisala pressure transmitter and barometer Malaysia
Pressure

Barometric and Differential Pressure Instruments

Barometric pressure and differential pressure serve different applications. For cleanroom pressure monitoring, check the pressure relationship and range between the two spaces. For atmospheric pressure, select a suitable barometer.

Product families: PTB barometers and PDT differential-pressure transmitters for suitable weather, laboratory, cleanroom and HVAC applications.

View pressure instruments →
Vaisala moisture in oil probe and transmitter Malaysia
Moisture in oil

Moisture-in-Oil Probes and Instruments

Moisture-in-oil measurement helps track the condition of compatible oils during operation. Instrument selection depends on the oil type, temperature, pressure and available connection. These details should be checked before deciding on the probe.

Product families: MMP moisture-in-oil probes and suitable portable configurations. Confirm compatibility with the oil and the measurement required.

View moisture-in-oil instruments →
Vaisala weather transmitter and WMT700 wind sensor Malaysia
Weather and wind

Weather Transmitters and Ultrasonic Wind Sensors

For outdoor installations, consider both the weather parameters and the conditions at the mounting point. Exposure, mounting position and the connection to your system should be reviewed together with the instrument selection.

Product families: WXT530 Series weather transmitters and WMT700 ultrasonic wind sensors.

View weather instruments →

Vaisala Applications in Malaysia

The same measurement parameter can serve different purposes from one site to another. These application guides explain where the instruments are used and what to check during selection.

local_hospital

Pharmaceutical — GxP Environmental and Process Monitoring

Measure environmental and process conditions in cleanrooms, production areas, storage and equipment. Define what each transmitter will measure, then review the records and alarms required from viewLinc CMS. The GxP scope should be agreed with the engineering and QA teams.

memory

Semiconductor — Critical Moisture and Process Measurement

Critical moisture measurement may be required in dry gases, drying processes and production equipment, alongside cleanroom humidity, temperature and pressure. Select low-dew-point instruments according to the process limits, pressure and installation arrangement.

battery_charging_full

Battery Manufacturing — Dry Rooms and Drying Processes

Dry rooms and drying processes need measurements that cover the specified moisture limits. Select suitable dew point instruments, and review the monitoring locations together with temperature and pressure requirements.

dns

Data Centres — Air and Cooling Measurement

Measure air conditions in server rooms, aisles and ventilation systems using suitable humidity and temperature instruments. Vaisala options also include differential-pressure measurement and TMI110 for cooling-water temperature. Select each instrument for its part of the air or cooling system.

ac_unit

HVAC — Room, Duct and Building Measurement

Room and duct instruments provide the readings used by the building control system. Choose HVAC humidity instruments, temperature sensors, CO₂ transmitters and pressure instruments according to the location, required accuracy and BMS interface.

settings_input_component

Compressed Air — Dew Point and Dryer Monitoring

Dew point measurement helps the maintenance team check air dryness and dryer performance. Consider the dryer type, working pressure and required dew point when selecting the instrument. Our portable dew point measurement guide covers checks at different points in the system.

invert_colors

Oil Moisture — Maintenance and Process Measurement

Use suitable moisture-in-oil instruments to follow dissolved moisture and temperature in compatible lubrication, hydraulic or transformer oils. Review the readings against the equipment conditions and maintenance requirements.

nature

Biogas and Biomethane Measurement

Raw-biogas measurement and methane-slip measurement in upgrading offgas require different probe capabilities. Confirm the gas composition, concentration range and process conditions before selecting the instrument.

wb_sunny

Weather and Wind Monitoring

For exposed sites, the mounting position and installation conditions affect the measurement. Select suitable weather and wind instruments for the parameters required, and review how the readings will reach the monitoring system.

Portable Meter or Permanent Transmitter?

The choice depends on how often you need the reading and what you will do with it.

settings

Permanent Transmitter

A fixed transmitter remains at the measurement point and sends readings to a suitable control or monitoring system. Choose this arrangement when the process needs continuous measurement. Recording and alarms depend on the connected equipment and configuration.

work

Portable Meter

A portable meter is suitable for periodic checks, commissioning and troubleshooting at several locations. Select the probe and sampling accessories for the application, and allow the reading to stabilise before making a comparison.

Read the portable dew point meter guide →

Replacing an Existing Vaisala Instrument

When replacing an older Vaisala instrument, check more than the model series. The measuring range, output, power supply, process connection and probe dimensions all need to suit the existing installation.

For example, DMT153 can be considered when reviewing a DMT152 replacement. An older DMT340-series installation may require a suitable DMP probe with a compatible Indigo transmitter. The replacement arrangement depends on the complete model code and configuration.

Send us a clear photo of the instrument label and, if available, the existing specification or wiring details. This helps us check the suitable replacement and identify any installation changes before you order.

Information to Include with Your Enquiry

Send the information you have available. The following details help us select the instrument and prepare a more accurate quotation:

  • straighten What you need to measure, the operating range and required accuracy.
  • place The application, the medium being measured and the installation location.
  • whatshot The process temperature, pressure and any condensation or cleaning exposure.
  • power The available power supply and the signal or communication required by your system.
  • build The probe length, mounting connection and cable length required.
  • description Any calibration, alarm, monitoring, qualification or documentation requirements.
  • label The complete model and order code if you are replacing an existing instrument.
Vaisala products and projects in Malaysia

Discuss Your Vaisala Requirements with Seacom

Contact Seacom with your Vaisala model number, application details or project specification. We can review the instrument selection, check the required accessories and prepare a quotation.

For contractors and project teams, please include the quantities, required delivery date and relevant specification. Let us know if supporting documents are needed for submission so these can be reviewed with the quotation requirements.

Active filters

Hydrogen Peroxide H2O2, Humidity, And Temperature Probe HPP270
  • Out-of-Stock

The Vaisala HPP270 Series provides stable, repeatable measurement for demanding vaporized hydrogen peroxide bio-decontamination processes.

  • HPP271 measures vaporized H₂O₂ concentration
  • HPP272 adds relative saturation, relative humidity and temperature
  • H₂O₂ measurement range from 0 to 2000 ppm
  • Accuracy of ±10 ppm or 5% of reading, whichever is greater
  • Two 4–20 mA outputs or RS-485 with Modbus RTU
  • IP65 stainless-steel construction with Vaisala PEROXCAP® technology
  • Compatible with Vaisala Indigo transmitters and Indigo80
Vaisala WXT530 Weather Transmitter| Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The compact Vaisala WXT530 Series measures wind, precipitation, barometric pressure, air temperature and relative humidity in selectable combinations for industrial and environmental weather monitoring.

  • Choose one to six essential weather parameters
  • Ultrasonic wind and acoustic precipitation measurement
  • No moving parts and low maintenance requirements
  • Modbus RTU, SDI-12, ASCII and NMEA communication options
Vaisala MM70 Discontinued | Indigo80 MMP8 Replacement
  • Out-of-Stock

The Vaisala MM70 was a portable meter for spot-checking water activity and temperature in transformer, lubrication and hydraulic oils.

  • Discontinued product; not recommended for new purchases
  • Legacy MI70 handheld indicator with MMP78 moisture-in-oil probe
  • Water-activity measurement from 0 to 1 aw
  • Temperature measurement from −40 to +100 °C
  • Direct insertion through a ball valve without draining the process
  • Numerical display, trend graph and portable data logging
Vaisala MMT330 Discontinued | MMP8 Replacement | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala MMT330 Series provided continuous measurement of moisture and temperature in transformer oil, lubrication oil, hydraulic fluid and other liquid hydrocarbons.

  • Discontinued series; not recommended for new installations
  • Legacy MMT332, MMT337 and MMT338 probe configurations
  • Measures water activity, relative saturation, temperature and calculated ppm
  • Graphical display, data logging and versatile analogue or digital outputs
  • Used for oil-condition monitoring, dryer control and free-water risk detection
  • Use Vaisala MMP8 with an Indigo transmitter for new installations
Vaisala MMT310 Moisture in Oil Transmitter | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

Vaisala HUMICAP® MMT310 Series provides continuous online measurement of moisture and temperature in transformer, lubrication and hydraulic oils.

The compact transmitter measures water activity (aw) or relative saturation (%RS), showing how close the oil is to forming free water. Optional ppm calculation is available for mineral transformer oil and configured oil types.

  • Models MMT317 and MMT318
  • Water activity range: 0 to 1 aw
  • Temperature range: -40 to +180°C
  • Two configurable analogue outputs and RS-232C
  • Up to 40 bar with MMT318 and ball-valve installation
  • IP66 compact transmitter enclosure
  • Traceable calibration certificates included
Vaisala Indigo510 Indigo520 Malaysia
  • Out-of-Stock

The Vaisala Indigo500 Series provides flagship industrial measurement integration: choose Indigo510 for a simplified single-probe system or Indigo520 for full dual-probe capability.

  • Indigo510: one probe and two isolated analog outputs
  • Indigo520: two probes, four isolated outputs and two relays
  • Ethernet web interface and Modbus TCP communication
  • Rugged IP66 and NEMA 4 metal enclosure
Humidity and Temperature Transmitter (Meteorological Grade) HMP155
  • Out-of-Stock

The Vaisala HMP155 provides stable humidity and temperature measurement for automatic weather stations, road-weather systems, airports, research sites and demanding outdoor monitoring.

  • Relative-humidity measurement from 0 to 100 %RH
  • Operating range from −80 to +60 °C
  • HMP155A with two analogue voltage outputs
  • HMP155D with RH voltage output and passive four-wire Pt100 temperature
  • HMP155E with RS-485 digital output
  • Optional warmed probe, chemical purge and additional temperature sensor
Vaisala HMP3
  • Out-of-Stock

The Vaisala HMP3 is a high-accuracy, field-maintainable probe for industrial HVAC, air-handling units, cleanrooms, paint booths and environmental chambers.

  • Humidity accuracy up to ±0.8% RH
  • Temperature measurement from −40 to +120 °C
  • Field-replaceable filter and HUMICAP sensor option
  • Standalone Modbus RTU or Vaisala Indigo transmitter operation
Vaisala HMP7
  • Out-of-Stock

The Vaisala HMP7 is designed for continuously humid, rapidly changing and near-condensing environments. Probe heating helps prevent condensation while maintaining reliable process measurement.

  • Humidity accuracy up to ±0.8% RH
  • Probe heating for condensation prevention
  • −70 to +180 °C probe-head measurement range
  • Standalone Modbus RTU or Vaisala Indigo transmitter operation
Vaisala HMP8
  • Out-of-Stock

The Vaisala HMP8 provides high-accuracy humidity and temperature measurement in compressed air, refrigerant dryers and pressurised industrial processes up to 40 bar.

  • Humidity accuracy up to ±0.8% RH
  • Operating pressure from vacuum to 40 bar
  • Adjustable insertion depth with two probe lengths
  • Optional ball valve for insertion and removal under process conditions
Vaisala HMP9
  • Out-of-Stock

The Vaisala HMP9 combines a miniature 5 mm probe head with fast-response, high-accuracy humidity and temperature measurement for tight spaces and rapidly changing environments.

  • Humidity accuracy up to ±0.8% RH
  • Temperature accuracy up to ±0.1 °C
  • −40 to +120 °C probe-head measurement range
  • Standalone Modbus RTU or Vaisala Indigo transmitter operation
Indigo200 Series Transmitters for Vaisala smart probes for Vaisala Smart Probes
  • Out-of-Stock

The Vaisala Indigo200 Series is the standard transmitter platform for one interchangeable Indigo-compatible smart probe, providing local display and practical automation-system connectivity.

  • Indigo201 with three analog outputs and two relays
  • Indigo202 with Modbus RTU and two relays
  • Colour display with numerical and graphical views
  • IP65 enclosure for industrial measurement applications
This website uses cookies to ensure you get the best experience on our website