Anritsu CS Series Micro Surface Temperature Probes

The Anritsu CS Series features small sensing heads for contact temperature measurement on stationary surfaces, particularly where space limits the use of larger probes.

  • Type K and Type E thermocouple options.
  • Head sizes from 3 mm diameter, depending on model.
  • −50 to 400°C range for CS-0, CS-1, CS-2 and CS-3 families.
  • −50 to 600°C range for the CS-7 family.
  • Straight and angled configurations with selectable shaft lengths, cables and connectors.

Select the sensing head and connection to suit the measurement point and thermometer.

Need advice or a quotation?

Ask Seacom about specifications, availability and the right instrument for your application.

Anritsu CS Series Micro Surface Temperature Probes

The Anritsu CS Series comprises compact thermocouple probes for measuring stationary surface temperatures. Small sensing heads help reach measurement points where a larger surface probe would be difficult to position.

Choose the head size, shaft arrangement and instrument connection to suit the application. These are contact probes and require a compatible thermometer or thermocouple data logger.

Key Features

  • Small sensing heads for stationary surfaces.
  • Type K and Type E thermocouple options.
  • Selected models cover −50 to 400°C or −50 to 600°C.
  • Straight and angled configurations for different access conditions.
  • Choices of shaft length, handle, cable and connector.

Anritsu CS Series micro surface temperature probes

Compare CS Probe Families

FamilyHead sizeTemperature range
CS-0* 3.0 mm diameter −50 to 400°C
CS-1* 4.2 mm diameter −50 to 400°C
CS-2* 6 mm diameter −50 to 400°C
CS-3* 2 × 10 mm −50 to 400°C
CS-7* 6 mm diameter −50 to 600°C

The asterisk represents the selected model digit. The temperature rating applies to the sensing head; the handle, cable and plug have separate operating limits.

Model Selection and Dimensions

Anritsu CS Series head dimensions and ordering guide

Model Pictures and Complete Example Codes

Each example below uses a 100 mm shaft, standard handle, 1 m TC cable and ANP miniature connector. Confirm the complete configuration and thermocouple input before ordering.

CS-01 Micro Surface Probe

SpecificationCS-01

Anritsu CS-01 micro surface temperature probe drawing

Type K example CS-01K-010-1-TC1-ANP
Type E example CS-01E-010-1-TC1-ANP
Temperature range −50 to 400°C
Tolerance at a 100°C surface ±3.0°C
Response time under test conditions 3 seconds

CS-03 Micro Surface Probe

SpecificationCS-03

Anritsu CS-03 micro surface temperature probe drawing

Type K example CS-03K-010-1-TC1-ANP
Type E example CS-03E-010-1-TC1-ANP
Temperature range −50 to 400°C
Tolerance at a 100°C surface ±3.0°C
Response time under test conditions 3 seconds

CS-11 Micro Surface Probe

SpecificationCS-11

Anritsu CS-11 micro surface temperature probe drawing

Type K example CS-11K-010-1-TC1-ANP
Type E example CS-11E-010-1-TC1-ANP
Temperature range −50 to 400°C
Tolerance at a 100°C surface ±2.5°C
Response time under test conditions 2 seconds

CS-13 Micro Surface Probe

SpecificationCS-13

Anritsu CS-13 micro surface temperature probe drawing

Type K example CS-13K-010-1-TC1-ANP
Type E example CS-13E-010-1-TC1-ANP
Temperature range −50 to 400°C
Tolerance at a 100°C surface ±2.5°C
Response time under test conditions 2 seconds

CS-21 Micro Surface Probe

SpecificationCS-21

Anritsu CS-21 micro surface temperature probe drawing

Type K example CS-21K-010-1-TC1-ANP
Type E example CS-21E-010-1-TC1-ANP
Temperature range −50 to 400°C
Tolerance at a 100°C surface ±2.5°C
Response time under test conditions 2 seconds

CS-36 Micro Surface Probe

SpecificationCS-36

Anritsu CS-36 micro surface temperature probe drawing

Type K example CS-36K-010-1-TC1-ANP
Type E example CS-36E-010-1-TC1-ANP
Temperature range −50 to 400°C
Tolerance at a 100°C surface ±2.5°C
Response time under test conditions 2 seconds

CS-73 Micro Surface Probe

SpecificationCS-73

Anritsu CS-73 micro surface temperature probe drawing

Type K example CS-73K-010-1-TC1-ANP
Type E example CS-73E-010-1-TC1-ANP
Temperature range −50 to 600°C
Tolerance at a 100°C surface ±2.5°C
Response time under test conditions 2 seconds

Tolerance by Surface Temperature

Surface temperatureCS-0*CS-1*, CS-2*, CS-3*CS-7*
−50 to −40°C ±3.5°C ±2.5°C ±2.5°C
Above −40 to 100°C ±3.0°C ±2.5°C ±2.5°C
Above 100 to 200°C ±5.0°C ±3.1°C ±3.1°C
Above 200 to 300°C ±7.5°C ±5.0°C ±5.0°C
Above 300 to 400°C ±10.0°C ±6.3°C ±6.3°C
Above 400 to 500°C Outside rated range Outside rated range ±8.0°C
Above 500 to 600°C Outside rated range Outside rated range ±13.0°C

Specifications use a stationary, flat, smooth metal surface. Response is the time to reach 99% of the true value. Published durability exceeds 50,000 contacts under a 300°C surface test; actual service life depends on use. The probes have SUS304 shafts and phenolic-resin handles and are listed as repairable, subject to assessment.

Understanding the Order Code

For CS-11K-010-1-TC1-ANP, the code identifies the head and shaft arrangement, Type K thermocouple, 100 mm shaft, standard handle, 1 m TC cable and miniature connector.

  • Shaft length: codes 005, 010 and 015 represent 50, 100 and 150 mm.
  • Handle: 1 indicates a standard handle; 0 indicates no handle.
  • Cable: TC is used with the standard handle; TS with handle-free versions.
  • Connector: ANP is the miniature plug and ASP is the Anritsu standard plug. Other terminations are available.

Some combinations cannot be manufactured. Use the complete order code when checking supply or replacing an existing probe.

Additional Model References

These references retain the configurations listed on the existing Seacom page. The ending *** is a connector placeholder, not a complete ordering code.

Model / referenceModel / reference
CS-01K-010-0-TS1-*** CS-01K-015-0-TS1-***
CS-01K-005-1-TC1-*** CS-01K-010-1-TC1-***
CS-01K-015-1-TC1-*** CS-03K-010-0-TS1-***
CS-03K-015-0-TS1-*** CS-03K-005-1-TC1-***
CS-03K-010-1-TC1-*** CS-03K-015-1-TC1-***
CS-11K-010-0-TS1-*** CS-11K-015-0-TS1-***
CS-11K-005-1-TC1-*** CS-11K-010-1-TC1-***
CS-11K-015-1-TC1-*** CS-13K-010-0-TS1-***
CS-13K-015-0-TS1-*** CS-13K-005-1-TC1-***
CS-13K-010-1-TC1-*** CS-13K-015-1-TC1-***
CS-21K-005-0-TS1-*** CS-21K-010-0-TS1-***
CS-21K-015-0-TS1-*** CS-21K-005-1-TC1-***
CS-21K-010-1-TC1-*** CS-21K-015-1-TC1-***
CS-23K-005-0-TS1-*** CS-23K-010-0-TS1-***
CS-23K-015-0-TS1-*** CS-23K-005-1-TC1-***
CS-23K-010-1-TC1-*** CS-23K-015-1-TC1-***
CS-31K-015-0-TS1-*** CS-31K-010-1-TC1-***
CS-31K-015-1-TC1-*** CS-33K-010-0-TS1-***
CS-33K-015-0-TS1-*** CS-33K-005-1-TC1-***
CS-33K-010-1-TC1-*** CS-33K-015-1-TC1-***
CS-36K-010-0-TS1-*** CS-36K-015-0-TS1-***
CS-36K-005-1-TC1-*** CS-36K-010-1-TC1-***
CS-36K-015-1-TC1-***

CS Series Video

Choosing the Right Micro Surface Probe

  • Target area: check that the sensing head fits fully on the measurement surface.
  • Access: select a straight or angled shaft that allows stable contact.
  • Surface condition: coatings, roughness and curvature can affect contact and the reading.
  • Temperature: select the probe for the highest expected surface temperature.
  • Instrument: match Type K or E and the connector to the thermometer input.

A small sensing head does not eliminate contact error. Allow the reading to stabilise and use a repeatable contact method when comparing measurements.

Related Anritsu Instruments and Probes

Confirm the thermocouple input and connector configuration before pairing a probe with an instrument.

Need Help Selecting a CS Probe?

Contact Seacom Process Instruments Sdn Bhd with the target dimensions, surface material, temperature range, access restrictions and thermometer model. For a replacement, include a photograph of the existing probe and its complete order code.

Product documents

Catalogues, manuals and other files available for this instrument.

CS Series Catalogue

Micro Sensor Probe CS Series

1.91MB
Download

You might also like

6, 12 Channels Temperature DataLogger AM-9000 Series
  • Out-of-Stock

The Anritsu AM-9000 Series records temperature from six or twelve thermocouple channels in one portable instrument. Choose a fixed thermocouple-type model or a flexible multi-input model for temperature and DC-voltage measurement.

  • Choice of 6-channel or 12-channel instruments
  • Fixed thermocouple-type and multi-input versions
  • Supports E, K, J, T and R thermocouples according to model
  • 120,000 measurement-data memory
  • USB 2.0 Micro-B communication for data transfer
  • Battery operation or optional AC adaptor
  • Optional AMS-950 software for PC analysis

Ask Seacom about the AM-9000 Series

Anritsu AP-400 & AP-450 Handheld Thermo Printer
  • Out-of-Stock

The Anritsu AP-400 Series combines a high-accuracy thermocouple thermometer with a built-in thermal printer. Measurements can be printed immediately, printed automatically at selected intervals or stored and printed later.

  • Single-channel handheld thermometer with built-in printer
  • Manual, interval and sequential-number printing
  • Stores up to 100 measurements for batch printing
  • AP-400 supports Type E or K with an ASP connector
  • AP-450 supports Type E, K, J, T or R with an ANP connector
  • Thermocouple type is selected when ordering and is not switchable
  • Powered by four AA batteries or an optional AC adaptor

Ask Seacom about the AP-400 Series

16 other products in the same category:

Vaisala HM70 Portable Meter| Replaced by Indigo80 HMP80
  • Out-of-Stock

The Vaisala HM70 was a handheld meter for humidity and temperature spot checks, field measurements, data logging and verification of installed Vaisala instruments. It is discontinued and replaced by the Vaisala Indigo80 handheld indicator with an HMP80 probe.

  • Legacy MI70 handheld indicator with HMP75, HMP76 or HMP77 probe
  • Relative-humidity measurement from 0 to 100 %RH
  • Probe-dependent temperature measurement from −70 to +180 °C
  • Numerical and graphical display with portable data recording
  • Current replacement: Indigo80 with HMP80N or HMP80L
  • HMP80N for general measurements; HMP80L for extended temperature reach
Hydrogen Peroxide H2O2, Humidity, And Temperature Probe HPP270
  • Out-of-Stock

The Vaisala HPP270 Series provides stable, repeatable measurement for demanding vaporized hydrogen peroxide bio-decontamination processes.

  • HPP271 measures vaporized H₂O₂ concentration
  • HPP272 adds relative saturation, relative humidity and temperature
  • H₂O₂ measurement range from 0 to 2000 ppm
  • Accuracy of ±10 ppm or 5% of reading, whichever is greater
  • Two 4–20 mA outputs or RS-485 with Modbus RTU
  • IP65 stainless-steel construction with Vaisala PEROXCAP® technology
  • Compatible with Vaisala Indigo transmitters and Indigo80
Sato SK-L200TH II Discontinued | SK-L754 Replacement | Seacom
  • Out-of-Stock

The Sato SK-L200TH II temperature and humidity data logger is discontinued. The replacement is the Sato SK-L754, selected with a compatible temperature and humidity probe.

  • Electronic temperature and humidity recording.
  • 16,000 stored readings per channel.
  • USB communication and microSD data transfer.
  • Choice of plug-in or cabled probe, purchased separately.

View the Sato SK-L754 replacement and probe options.

Badger Meter ModMAG M2000 electromagnetic flow meter
  • Out-of-Stock

The Badger Meter ModMAG M2000 measures conductive liquid flow, with applications in data centre chilled-water and cooling-water systems. Communication options support integration with building and plant monitoring systems.

  • Flow velocity range: 0.03–12 m/s
  • Accuracy: ±0.20% of reading ±1 mm/s with suitable straight pipe
  • Integral or remote transmitter arrangements
  • BACnet, Modbus and other communication options
  • Zero-straight-run capability subject to specified conditions
Vaisala DMT132 Dew Point Transmitter | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DMT132 is a compact and economical dew-point transmitter designed to verify refrigerant-dryer performance by measuring the actual outlet-air dew point.

  • Dew-point measurement range from −30 to +50 °C Td/f
  • Accuracy up to ±1 °C in the typical refrigerant-dryer range
  • Two-wire, loop-powered 4–20 mA output
  • Operating pressure up to 20 bar
  • Resistant to condensation and compressor oil
  • Optional warning LED and loop-powered display
Duct Mounted CO2 Transmitter GMD10
  • Out-of-Stock

The Vaisala GMD110 measures carbon dioxide directly inside ventilation ducts for precise HVAC control and demand-controlled ventilation.

  • CO₂ measurement range from 0 to 10,000 ppm
  • Accuracy of ±40 ppm from 0 to 3000 ppm
  • 4–20 mA, 0–5 V, 0–10 V or Modbus RTU output options
  • Analogue scaling of 0–2000, 0–5000 or 0–10,000 ppm
  • Fast response with less than two minutes to full specification
  • Heated CARBOCAP® sensor head helps prevent condensation
  • IP65 enclosure for demanding duct installations
  • Traceable calibration certificate included
Anritsu VA Clip-Type Temperature Probes | Seacom
  • Out-of-Stock

The Anritsu VA Series uses a clip-type sensing arrangement to measure heat-pipe surface temperature. Select the probe to suit the pipe dimensions and connected instrument.

  • Clip-type design for heat-pipe surface measurement.
  • Published configurations cover −50 to 300°C.
  • Type K and Type E thermocouple options.
  • VA-03, VA-04, VA-05 and VA-06 model options.
Vaisala TMP1
  • Out-of-Stock

The Vaisala TMP1 is a robust temperature-only probe for demanding industrial processes, pharmaceutical applications and calibration laboratories.

  • Temperature measurement range from −70 to +180 °C
  • Accuracy up to ±0.1 °C at +23 °C with standard calibration
  • Pt100 RTD Class F0.1 sensor according to IEC 60751
  • Standalone Modbus RTU over RS-485
  • Compatible with Vaisala Indigo200, Indigo300, Indigo500 and Indigo80
  • Traceable two-point calibration certificate included
  • Ask Seacom about the suitable TMP1 configuration
Dickson Touch Screen Data Logger TWP
  • Out-of-Stock

The DicksonOne TWP provides local touchscreen viewing and cloud-connected monitoring of temperature, relative humidity or differential pressure. Its replaceable sensor system simplifies calibration and supports different monitoring applications using the same logger platform.

  • Large 8-inch LCD touchscreen
  • WiFi, Ethernet and Power over Ethernet connectivity
  • Approximately 1,000,000 sample-point backup capacity
  • Up to 70 hours of rechargeable battery backup
  • Replaceable temperature, humidity, thermocouple, RTD and differential-pressure sensors
  • Phone, text and email alarms through a DicksonOne subscription
Anritsu MG Magnet Probe
  • Out-of-Stock

The Anritsu MG Series magnetic temperature probes attach to suitable stationary surfaces for surface temperature measurement.

  • Built-in magnets for secure attachment to magnetically receptive surfaces.
  • Type K and Type E thermocouple configurations.
  • Temperature ranges from −50°C to 250°C or 400°C, depending on the model.
  • Different sensing heads and cable options to suit the installation.
Smart Humidity and Temperature Probe for high temperature HMP5
  • Out-of-Stock

The Vaisala HMP5 provides high-accuracy humidity and temperature measurement in ovens, dryers, kilns and other processes operating at temperatures up to +180 °C.

  • Humidity accuracy up to ±0.8% RH
  • Temperature accuracy up to ±0.1 °C
  • −70 to +180 °C probe-head measurement range
  • Standalone Modbus RTU or Vaisala Indigo transmitter operation
Recording Pens, Ink Ribbons and Recorder Consumables | SL
  • Out-of-Stock

Replacement recording pens, ink ribbons, cartridge pens and refill ink for chart recorders and thermohygrographs.

  • Options for Dickson, Sekonic, Chino, Yokogawa, Sato, Isuzu and other brands
  • Selection by recorder model, consumable reference and ink colour
  • Send us your existing pen or ribbon details to confirm compatibility and availability
Vaisala DPT146 Dew Point Transmitter - Discontinued
  • Out-of-Stock

The Vaisala DPT146 combines dew-point and process-pressure measurement in one compact transmitter for compressed-air systems. This model is discontinued and should not be selected for new projects.

  • Dew-point measurement from −70 to +30 °C Td
  • Absolute-pressure measurement from 1 to 12 bar
  • Pressure-compensated dew point and ppm calculation
  • Analog outputs and RS-485 with Modbus RTU
  • Contact Seacom for existing-unit support and replacement assessment
Vaisala Immersion Temperature Transmitter TMI110
  • Out-of-Stock

The Vaisala TMI110 provides high-accuracy temperature measurement for data-centre chilled-water systems, HVAC cooling and heating circuits, and ventilation ducts.

  • ±0.1 °C accuracy at +20 °C
  • Fast response time of less than 8 seconds
  • 4–20 mA or Modbus RTU output options
  • IP65 enclosure with traceable calibration certificate
Vaisala HMP110
  • Out-of-Stock

The Vaisala HMP110 is a high-accuracy humidity and temperature probe designed for demanding equipment integration, environmental chambers, data loggers, incubators and controlled-environment applications.

It provides ±1.5% RH accuracy, a 0–100% RH range, −40 °C to +80 °C temperature measurement, a chemically resistant HUMICAP 180R sensor and analog or Modbus RTU output options.

Vaisala MM70 Discontinued | Indigo80 MMP8 Replacement
  • Out-of-Stock

The Vaisala MM70 was a portable meter for spot-checking water activity and temperature in transformer, lubrication and hydraulic oils.

  • Discontinued product; not recommended for new purchases
  • Legacy MI70 handheld indicator with MMP78 moisture-in-oil probe
  • Water-activity measurement from 0 to 1 aw
  • Temperature measurement from −40 to +100 °C
  • Direct insertion through a ball valve without draining the process
  • Numerical display, trend graph and portable data logging