    Vaisala DL4000 Universal Data Logger | Vaisala Distributor Malaysia | Seacom

Vaisala DL4000 Universal Input Data Logger for viewLinc CMS

The Vaisala DL4000 records current or voltage signals from industrial transmitters and brings pressure, flow, level, pH, moisture, gas concentration and other process measurements into viewLinc.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Closest current substitute: Vaisala VDL200 with ANP115 analog input probe
  • Available with 1, 2 or 4 analog input channels
  • Supports 0–20 mA, 0–5 V DC or 0–10 V DC models
  • 120,000-sample onboard memory and a 10-year battery

Need advice or a quotation?

Ask Seacom about specifications, availability and the right instrument for your application.

Vaisala DL4000 Universal Input Data Logger

Product lifecycle notice: The DL4000 is scheduled for future discontinuation. Confirm product availability before specifying it for a new project. For new analog-input monitoring systems, consider the Vaisala VDL200 with ANP115 analog input probe.

The Vaisala DL4000 records standard current or voltage signals from industrial transmitters and sensors. It allows measurements such as differential pressure, flow, fluid level, pH, electrical properties, moisture and gas concentration to be monitored alongside temperature and humidity within a Vaisala viewLinc system.

The logger is available with one, two or four channels. Separate models accept 0–20 mA, 0–5 V DC or 0–10 V DC inputs. Each channel can be scaled in engineering units so users see the actual process value rather than the raw electrical signal.

Connected to the Vaisala viewLinc Continuous Monitoring System, the DL4000 provides historical and real-time data, remote alarms and controlled reporting. It can also be used with Vaisala vLog for standalone graphing and reporting.

At a GlanceDL4000
Input types 0–20 mA, 0–5 V DC or 0–10 V DC, depending on model
Channel configurations 1, 2 or 4 channels
Input accuracy ±0.15% of full scale at +25 °C
Memory 120,000 12-bit samples
Power Internal lithium battery with a specified 10-year life at intervals of one minute or longer

Closest Substitute: VDL200 with ANP115

The closest current substitute for many DL4000 applications is the Vaisala VDL200 PoE Data Logger used with an ANP115 analog input probe. The ANP115 allows a compatible current or voltage signal to be incorporated into the current viewLinc platform.

ConsiderationDL4000VDL200 with ANP115
Product generation Legacy DL-series platform approaching phase-out Current-generation viewLinc platform
Input purpose Records standard current or voltage signals ANP115 connects compatible analog signals to VDL200
Channel arrangement Dedicated 1-, 2- or 4-channel model Configuration depends on the VDL200 probe and input arrangement
Network connection RS-232 with optional USB, Ethernet, PoE or Wi-Fi interface Native Ethernet and Power over Ethernet
Migration requirement Existing configuration may remain in service Signal range, scaling, wiring, power and viewLinc compatibility must be reviewed
Not always a direct one-for-one replacement: A DL4000 can provide up to four dedicated analog channels. Confirm the number of signals, input ranges, transmitter power requirements and network arrangement before migrating to VDL200 and ANP115.

What Can the DL4000 Monitor?

The DL4000 does not measure the physical parameter directly. It records the standard electrical output from a compatible transmitter, then converts that signal into the required engineering range.

  • Differential pressure: Cleanrooms, isolation rooms, filters and air-handling systems.
  • Flow: Liquid, gas or air flow transmitters with a compatible analog output.
  • Level: Tanks, vessels and storage systems.
  • Gas concentration: Fixed transmitters for CO₂ or other process gases.
  • Moisture and dew point: Transmitters monitoring compressed air, oils or industrial gases.
  • Electrical and process values: Conductivity, pH, particles and other parameters converted to a standard analog signal.

Choosing the Correct Input Model

DL4000 ModelInput RangeUse When the Transmitter Output Is
4000-405 0–5 V DC 0–5 V
4000-40A 0–10 V DC 0–10 V
4000-40C 0–20 mA 0–20 mA or a compatible scaled current signal
Check before ordering: The DL4000 model is factory-configured for one input type. Confirm the transmitter output, number of channels, scaling range, engineering unit and power arrangement before selecting the model code.

How Signal Scaling Works

Each channel is configured with the transmitter’s electrical and measurement ranges. For example, a differential-pressure transmitter scaled from 0 to 100 Pa with a 0–10 V output can be displayed, alarmed and reported by viewLinc directly in pascals.

Configuration ItemExample
Input signal 0–10 V DC
Transmitter range 0–100 Pa
Engineering unit Pa
Displayed result The actual differential-pressure value rather than the raw voltage
Alarm limits Configured in viewLinc using the scaled engineering value

Recording at the Measurement Point

  • Network-independent recording: Measurements continue to be stored if network communication is interrupted.
  • Battery-backed operation: The internal battery supports autonomous logging during a mains-power interruption.
  • Gap-free records: Stored data can be transferred to viewLinc after communication is restored.
  • Flexible recording intervals: Sampling can be selected from once every 10 seconds to once per day.
  • Controlled memory behaviour: Choose FIFO wrap mode or stop recording when memory is full.

DL4000 Recording Capacity

Sample Interval1 Channel2 Channels4 Channels
10 seconds 13.8 days 6.9 days 3.4 days
1 minute 2.7 months 1.3 months 20.8 days
5 minutes 1.1 years 6.9 months 3.4 months
15 minutes 3.4 years 1.7 years 10.4 months
1 hour 13.6 years 6.8 years 3.4 years

viewLinc and System Connectivity

Connection or SoftwarePurpose
RS-232 Native local serial connection
USB Direct computer connection using the appropriate interface cable
Ethernet or PoE Network connection using the Vaisala vNet interface
Wi-Fi Wireless network connection using the compatible Vaisala interface
viewLinc Enterprise Server Continuous monitoring, remote alarms, audit trails and reports
vLog Standalone graphing, reporting or validation workflows
OPC integration Makes compatible monitoring data available to third-party systems

The complete viewLinc system can support records and workflows designed to meet FDA 21 CFR Part 11 and EU GMP Annex 11 requirements. Compliance depends on the complete system configuration, validation and operating procedures.

Technical Specifications

Current input 0–20 mA; 5.5 µA resolution; 75 Ω input impedance
Voltage inputs 0–5 V DC or 0–10 V DC; 0.025% full-scale resolution; input impedance greater than 1 MΩ
Input accuracy ±0.15% of full scale at +25 °C
Operating environment −40 to +85 °C; 0–100% RH, non-condensing
Memory Non-volatile EEPROM; 120,000 12-bit samples
Sampling interval User selectable from once every 10 seconds to once per day
Internal clock accuracy ±1 minute/month at −25 to +70 °C
Dimensions 85 × 59 × 26 mm
Weight 76 g

DL4000 or Another Vaisala Logger?

Monitoring RequirementRecommended Logger
One to four standard analog transmitter signals DL4000
Temperature and relative humidity DL2000
Two or four precision temperature channels DL1000 / DL1400 Series
Thermocouple measurement across extreme temperatures DL1700
Current-generation PoE logging with analog inputs VDL200 with ANP115

Vaisala DL4000 Supplier and System Integrator in Malaysia

Seacom Process Instruments supplies and supports the Vaisala DL4000 Universal Input Data Logger in Malaysia for pharmaceutical facilities, cleanrooms, laboratories, hospitals, warehouses, semiconductor manufacturing, utilities and other critical industrial environments. We can also assist existing DL4000 users with migration planning for the VDL200 and ANP115 platform.

Our team can assist with transmitter and input selection, signal scaling, monitoring-point planning, power and network architecture, viewLinc system integration, installation, commissioning, alarm configuration, calibration planning and GxP validation documentation.

Contact Seacom with the measured parameter, transmitter model, electrical output, engineering range, number of channels, sampling interval, network constraints and validation expectations. We can check whether a DL4000 is still appropriate or prepare a suitable VDL200 and ANP115 configuration.

Product documents

Catalogues, manuals and other files available for this instrument.

DL1016/DL1416 catalogue

Temperature Data Loggers DL1016/DL1416 (CMS, FDA Approved)

746.42KB
Download

DL1000/DL1400 catalogue

Temperature Data Loggers DL1000/DL1400 (CMS, FDA Approved)

1.28MB
Download

DL1700 catalogue

Thermocouple Data Loggers DL1700 (CMS, FDA Approved)

578.71KB
Download

HMT140 catalogue

Wi-Fi Data Logger (CMS, FDA Approved) HMT140

477.89KB
Download

DL4000 catalogue

Universal Input Data Logger (CMS, FDA Approved) DL4000

2.14MB
Download

DL2000 catalogue

Temperature And RH Data Logger (CMS, FDA Approved) DL2000

1008.79KB
Download

viewLinc catalogue

Continuous Monitoring System viewLinc (CMS, FDA Approved)

398.33KB
Download

You might also like

Temperature Data Loggers DL1016/1416 (CMS, FDA Approved)
  • Out-of-Stock

Vaisala DL1000, DL1400, DL1016 and DL1416 temperature data loggers provide reliable, traceable monitoring for refrigerators, freezers, cold rooms, incubators and regulated facilities.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Current replacement platform: Vaisala VDL200 with suitable smart probes
  • Two- or four-channel configurations
  • External probe range down to −90 °C
  • Onboard memory and a typical 10-year battery life
Thermocouple Data Loggers DL1700 (CMS, FDA Approved)
  • Out-of-Stock

The Vaisala DL1700 is a four-channel thermocouple data logger for continuous monitoring and validation work at extreme temperatures.

  • Overall application range from −240 to +1760 °C, depending on thermocouple type
  • Accepts J, K, T, E, R and S thermocouples
  • Four thermocouple inputs plus an internal cold-junction reference
  • Works with Vaisala viewLinc for monitoring, alarms and compliant reporting
Temperature And RH Data Logger (CMS, FDA Approved) DL2000
  • Out-of-Stock

The Vaisala DL2000 combines precision temperature and relative-humidity monitoring with optional analog or door-contact inputs for viewLinc systems.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Current replacement platform: Vaisala VDL200 with suitable smart probes
  • Internal temperature and relative-humidity measurement
  • Optional current, voltage or Boolean input configurations
  • Onboard memory and a typical 10-year battery life
Vaisala DL4000 Universal Data Logger | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DL4000 records current or voltage signals from industrial transmitters and brings pressure, flow, level, pH, moisture, gas concentration and other process measurements into viewLinc.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Closest current substitute: Vaisala VDL200 with ANP115 analog input probe
  • Available with 1, 2 or 4 analog input channels
  • Supports 0–20 mA, 0–5 V DC or 0–10 V DC models
  • 120,000-sample onboard memory and a 10-year battery
Vaisala HMT140 Replacement with RFL100 | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala HMT140 Wi-Fi Data Logger has been discontinued and is no longer recommended for new monitoring systems.

  • Primary replacement: Vaisala RFL100 with AP10 VaiNet Access Point
  • Existing HMT140 installations can continue to be supported
  • Migration should be checked against the existing sensor and input type
  • Contact Seacom for replacement selection and viewLinc compatibility
Long Range Wireless Data Logger (CMS, FDA Approved) RFL100
  • Out-of-Stock

The Vaisala RFL100 uses secure, long-range VaiNet wireless technology to monitor temperature, relative humidity and carbon dioxide with the AP10 Access Point and viewLinc Continuous Monitoring System.

  • At least 50 m typical indoor wireless range
  • Up to 32 RFL100 data loggers per AP10
  • 30 days of local measurement memory
  • Approximately 18 months of battery operation for temperature and humidity monitoring
Vaisala Temperature and Humidity Logger VDL200
  • Out-of-Stock

The Vaisala VDL200 is a secure Power-over-Ethernet data logger for monitoring temperature, relative humidity, carbon dioxide and analog or Boolean inputs in controlled and GxP-regulated environments.

Designed for the Vaisala viewLinc Continuous Monitoring System, the VDL200 combines interchangeable smart probes, onboard memory and battery backup to provide reliable, gap-free environmental monitoring.

Vaisala Continuous Monitoring System viewLinc
  • Out-of-Stock

Vaisala viewLinc provides continuous monitoring, alarming and reporting for temperature, humidity, CO₂, differential pressure and other critical parameters in GxP-regulated and demanding industrial environments.

  • Supports FDA 21 CFR Part 11 and EU GMP Annex 11 requirements
  • Secure audit trails, access control, alarms and reports
  • Ethernet, PoE, Wi-Fi, VaiNet and Modbus connectivity
  • Scalable from a few monitoring points to thousands

9 other products in the same category:

Vaisala Temperature and Humidity Logger VDL200
  • Out-of-Stock

The Vaisala VDL200 is a secure Power-over-Ethernet data logger for monitoring temperature, relative humidity, carbon dioxide and analog or Boolean inputs in controlled and GxP-regulated environments.

Designed for the Vaisala viewLinc Continuous Monitoring System, the VDL200 combines interchangeable smart probes, onboard memory and battery backup to provide reliable, gap-free environmental monitoring.

Cabinet for Continuous Monitoring System (CMS)
  • Out-of-Stock

The Vaisala CAB100 centralises differential-pressure transmitters, analog inputs and interface components for cleanroom and industrial monitoring with the viewLinc Continuous Monitoring System.

  • Preconfigured cabinet for viewLinc monitoring systems
  • CAB100A and higher-capacity CAB100B models
  • Differential pressure, analog input and hazardous-area options
  • IP54 or IP66 enclosure protection, depending on model
Temperature Data Loggers DL1016/1416 (CMS, FDA Approved)
  • Out-of-Stock

Vaisala DL1000, DL1400, DL1016 and DL1416 temperature data loggers provide reliable, traceable monitoring for refrigerators, freezers, cold rooms, incubators and regulated facilities.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Current replacement platform: Vaisala VDL200 with suitable smart probes
  • Two- or four-channel configurations
  • External probe range down to −90 °C
  • Onboard memory and a typical 10-year battery life
Vaisala PDT101 PDT102 Pressure Transmitter | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala PDT101 and PDT102 provide precise low differential-pressure measurement for cleanrooms, isolation rooms, regulated facilities, data centres and air-handling systems.

  • PDT101 accuracy up to 0.40% of span
  • PDT102 high accuracy up to 0.25% of span
  • 4–20 mA or voltage output configurations
  • Compatible with Vaisala viewLinc monitoring solutions
Temperature And RH Data Logger (CMS, FDA Approved) DL2000
  • Out-of-Stock

The Vaisala DL2000 combines precision temperature and relative-humidity monitoring with optional analog or door-contact inputs for viewLinc systems.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Current replacement platform: Vaisala VDL200 with suitable smart probes
  • Internal temperature and relative-humidity measurement
  • Optional current, voltage or Boolean input configurations
  • Onboard memory and a typical 10-year battery life
Long Range Wireless Data Logger (CMS, FDA Approved) RFL100
  • Out-of-Stock

The Vaisala RFL100 uses secure, long-range VaiNet wireless technology to monitor temperature, relative humidity and carbon dioxide with the AP10 Access Point and viewLinc Continuous Monitoring System.

  • At least 50 m typical indoor wireless range
  • Up to 32 RFL100 data loggers per AP10
  • 30 days of local measurement memory
  • Approximately 18 months of battery operation for temperature and humidity monitoring
Vaisala HMT140 Replacement with RFL100 | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala HMT140 Wi-Fi Data Logger has been discontinued and is no longer recommended for new monitoring systems.

  • Primary replacement: Vaisala RFL100 with AP10 VaiNet Access Point
  • Existing HMT140 installations can continue to be supported
  • Migration should be checked against the existing sensor and input type
  • Contact Seacom for replacement selection and viewLinc compatibility
Vaisala Continuous Monitoring System viewLinc
  • Out-of-Stock

Vaisala viewLinc provides continuous monitoring, alarming and reporting for temperature, humidity, CO₂, differential pressure and other critical parameters in GxP-regulated and demanding industrial environments.

  • Supports FDA 21 CFR Part 11 and EU GMP Annex 11 requirements
  • Secure audit trails, access control, alarms and reports
  • Ethernet, PoE, Wi-Fi, VaiNet and Modbus connectivity
  • Scalable from a few monitoring points to thousands
Thermocouple Data Loggers DL1700 (CMS, FDA Approved)
  • Out-of-Stock

The Vaisala DL1700 is a four-channel thermocouple data logger for continuous monitoring and validation work at extreme temperatures.

  • Overall application range from −240 to +1760 °C, depending on thermocouple type
  • Accepts J, K, T, E, R and S thermocouples
  • Four thermocouple inputs plus an internal cold-junction reference
  • Works with Vaisala viewLinc for monitoring, alarms and compliant reporting
This website uses cookies to ensure you get the best experience on our website