Cart
Custom content

This is custom content

  • Out-of-Stock
    Smart Dew Point Probe and Transmitter DMP7
    Dew Point Probe DMP8
    Vaisala DMP7 Dew Point Probe | Vaisala Distributor Malaysia | Seacom
    Vaisala DMP7 Dew Point Probe | Vaisala Distributor Malaysia | Seacom

Vaisala DMP7 Compact Dew Point Probe for Tight Spaces

The Vaisala DRYCAP® Dew Point and Temperature Probe DMP7 is designed for accurate low-humidity measurement where installation space is limited.

  • Short 41 mm probe for remote installation in tight spaces
  • Dew point measurement range from −70 to +80 °C Td/f
  • Pressure-tight installation for processes from 0 to 10 bar
  • Use with Modbus RTU, an Indigo transmitter or the portable Indigo80 handheld indicator
  • Suitable for dry rooms, compressed air, industrial drying and semiconductor equipment

Need advice or a quotation?

Ask Seacom about specifications, availability and the right instrument for your application.

Vaisala DMP7 Dew Point and Temperature Probe

The Vaisala DMP7 is a compact industrial probe for measuring low dew points in locations where a conventional probe is difficult to install. Its short sensing head can be mounted directly in a process or connected remotely to an Indigo transmitter, making it particularly useful inside compact equipment, dry-air systems and restricted pipework.

Vaisala DRYCAP® sensor technology provides stable measurement in demanding low-humidity conditions. The sensor tolerates condensation, oil, dust and most chemicals, while automatic sensor purge helps maintain performance between calibration intervals.

DMP7 at a Glance

Measured parameters Dew point or frost point, temperature and calculated humidity parameters
Dew point range −70 to +80 °C Td/f
Continuous-use dew point range −70 to +45 °C Td/f
Dew point accuracy Up to ±2 °C Td/f
Temperature range 0 to +80 °C
Process pressure 0 to 10 bar with the pressure-tight fitting
Probe length 41 mm
Digital output Modbus RTU over RS-485
Sensor Vaisala DRYCAP® 180M

Why Choose the DMP7?

  • Fits restricted installations: the short probe is suited to compact machinery, narrow ducts and other locations with little insertion space.
  • Measures very dry conditions: the wide dew point range supports dry-room, compressed-air and industrial drying applications.
  • Installs directly in pressurised processes: the pressure-tight fitting supports in-line measurement up to 10 bar without a separate sampling system.
  • Recovers from demanding conditions: DRYCAP technology withstands condensation and common industrial contaminants.
  • Offers flexible integration: use the probe directly through Modbus RTU or add an Indigo transmitter for a display, analogue outputs, relays and expanded system connectivity.

Typical Applications

  • Semiconductor and battery-manufacturing equipment
  • Dry rooms and glove boxes
  • Compressed-air and dry-gas systems
  • Industrial dryers and drying cabinets
  • Blanket gases used in metal heat treatment
  • Compact process equipment with restricted installation space

Fixed or Portable Measurement

For straightforward digital integration, the DMP7 can operate as a standalone Modbus RTU device. Where a permanent local display, analogue signal, relay control or Ethernet connection is required, pair it with a compatible Vaisala Indigo transmitter.

Portable Use with Indigo80

The DMP7 can also connect to the Vaisala Indigo80 handheld indicator, turning the installed-probe technology into a portable measurement and diagnostic setup. Indigo80 can display live readings, log measurement data and support field checking or adjustment of compatible probes. Up to two compatible Vaisala measurement devices can be connected at the same time, which is useful when comparing locations or using a second probe for a supporting measurement.

Product distinction: DMP7 is an Indigo-compatible industrial probe that can be used with Indigo80. DMP80 is a separate portable dew point probe designed specifically for handheld measurement with Indigo80.

The DMP7 also works with Vaisala Insight PC software for configuration, diagnostics, data viewing and field calibration.

Choosing Between DMP7 and DMP8

Selection pointDMP7DMP8
Best suited to Tight spaces and compact equipment Pressurised pipelines requiring adjustable insertion depth
Maximum pressure 10 bar 40 bar
Installation Short, pressure-tight probe fitting Adjustable installation with a ball-valve option

Selection note: choose the DMP7 when physical clearance is the main constraint. For higher-pressure pipelines or installations that need adjustable probe depth and easy removal, consider the DMP8.

Installation and Ordering Considerations

Before selecting the probe and accessories, confirm the expected dew point, process temperature, operating pressure, available installation space, process connection and required output. Also decide whether the application needs direct Modbus communication, a permanent Indigo transmitter or portable operation with Indigo80.

Correct probe placement is important. The measurement point should represent the actual process condition and avoid stagnant pockets, leaks, ambient-air ingress and locations where condensate can collect.

Vaisala DMP Series Comparison

Choose the DMP probe according to the installation environment, process temperature, pressure and required dew point range.

ModelBest suited toDew point rangeTemperature or pressure limitInstallation
DMP1 Dry rooms, battery production and semiconductor manufacturing −70 to +80 °C Td/f Probe operating temperature −40 to +80 °C Compact fixed probe for distributed room monitoring
DMP5 Hot industrial dryers, ovens and process ducts −40 to +100 °C Td/f Process temperature up to +180 °C Long direct-insertion probe with adjustable mounting depth
DMP6 Very-high-temperature dryers, ovens and industrial processes −25 to +100 °C Td/f Direct process measurement from +100 to +350 °C Direct-insertion probe with a dedicated passive cooling set
DMP7 Tight spaces, compact equipment, dry gas and compressed air −70 to +80 °C Td/f Process pressure up to 10 bar Short 41 mm sensing head with pressure-tight fitting
DMP8 Pressurised compressed-air and industrial-gas pipelines −70 to +80 °C Td/f Process pressure up to 40 bar absolute Adjustable insertion depth with optional ball-valve installation

Quick selection: choose DMP1 for distributed dry-room monitoring, DMP5 for processes up to +180 °C, DMP6 for very hot processes up to +350 °C, DMP7 when installation space is limited, and DMP8 for pressurised pipelines up to 40 bar.

All five probes support Modbus RTU, compatible Vaisala Indigo transmitters, the Indigo80 handheld indicator and Vaisala Insight software. The final selection should also consider process gas, flow velocity, mounting access, required outputs and calibration arrangements.

DMP7 Videos

Technical Resources

Choose the right Vaisala dew point instrument


Vaisala dew point sensing technologies application note


Compressed-air dryer success story


Improving semiconductor wafer circuit pattern quality


Compressed-air dew point sampling guidance

Vaisala DMP7 Supplier and Technical Support in Malaysia

Seacom Process Instruments supplies and supports the Vaisala DMP7 Dew Point and Temperature Probe in Malaysia for semiconductor manufacturing, dry rooms, compressed-air systems, industrial drying and other low-humidity applications.

Our team can assist with probe selection, installation fittings, measurement-point review, Indigo transmitter pairing, portable Indigo80 arrangements, system integration, commissioning and calibration planning.

Contact Seacom with your dew-point range, process temperature and pressure, available mounting space, process connection and required output, and whether the measurement will be fixed or portable, so we can recommend a suitable DMP7 arrangement.

Product documents

Catalogues, manuals and other files available for this instrument.

DMP6 catalogue

Smart Dew Point Probe DMP6

1.02MB
Download

DMP5 catalogue

Smart Dew Point Probe DMP5

867.39KB
Download

DMP7 catalogue

Smart Dew Point Probe DMP7

615.81KB
Download

DMP8 catalogue

Smart Dew Point Probe DMP8

649.15KB
Download

Indigo200 catalogue

Indigo200 Series Transmitters for Vaisala smart probes for Vaisala Smart Probes

475.15KB
Download

Indigo 500 catalogue

Indigo500 Series Transmitters for Vaisala smart probes

1.02MB
Download

Indigo80 catalogue

Advanced Portable Meter Indigo80

683.21KB
Download

You might also like

Indigo200 Series Transmitters for Vaisala smart probes for Vaisala Smart Probes
  • Out-of-Stock

The Vaisala Indigo200 Series is the standard transmitter platform for one interchangeable Indigo-compatible smart probe, providing local display and practical automation-system connectivity.

  • Indigo201 with three analog outputs and two relays
  • Indigo202 with Modbus RTU and two relays
  • Colour display with numerical and graphical views
  • IP65 enclosure for industrial measurement applications
Vaisala Indigo510 Indigo520 Malaysia
  • Out-of-Stock

The Vaisala Indigo500 Series provides flagship industrial measurement integration: choose Indigo510 for a simplified single-probe system or Indigo520 for full dual-probe capability.

  • Indigo510: one probe and two isolated analog outputs
  • Indigo520: two probes, four isolated outputs and two relays
  • Ethernet web interface and Modbus TCP communication
  • Rugged IP66 and NEMA 4 metal enclosure

15 other products in the same category:

Vaisala DMP5 High-Temperature Dew Point Probe | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DRYCAP® Dew Point and Temperature Probe DMP5 measures humidity directly in hot industrial processes with a long stainless-steel probe and adjustable installation depth.

  • Direct in-line measurement at process temperatures up to +180 °C
  • Dew point measurement range from −40 to +100 °C Td/f
  • Long probe reaches through insulation and thick process walls
  • Built-in Modbus RTU or integration with Vaisala Indigo transmitters
  • Connect to Indigo80 for portable display, diagnostics, configuration and field calibration
Vaisala DMT340 Dewpoint Transmitter | Replaced by Indigo500 and DMP
  • Out-of-Stock

The Vaisala DMT340 Series provided configurable dew-point and temperature measurement for industrial low-humidity applications. The series is discontinued and replaced by Vaisala Indigo500 transmitters with DMP7 or DMP8 smart probes.

  • Former models: DMT341, DMT342, DMT344, DMT347 and DMT348
  • Designed for dry rooms, industrial dryers, compressed air and process gases
  • Legacy display, data logging, analog, relay and communication options
  • Use DMP7 for compact, wall-mounted or tight-space applications
  • Use DMP8 for pressurised processes and pipelines
  • Pair the selected probe with an Indigo500 transmitter
Vaisala DMT345 DMT346 Dewpoint Transmitter - Discontinued
  • Out-of-Stock

The Vaisala DMT345 and DMT346 provided direct dew-point measurement in hot industrial drying processes. Both models are discontinued and replaced by Vaisala DMP5 or DMP6 smart probes with an Indigo transmitter.

  • DMT345: former solution for processes up to +180 °C
  • DMT346: former solution for very hot processes up to +350 °C
  • DMT345 replacement: DMP5 with a suitable Indigo transmitter
  • DMT346 replacement: DMP6 with a suitable Indigo transmitter
  • Direct in-process measurement without a conventional sampling system
  • Contact Seacom for mechanical and electrical migration review
Vaisala Transmitter Indigo300
  • Out-of-Stock

The Vaisala Indigo300 is a rugged industrial transmitter for one Vaisala Indigo-compatible smart probe, providing local measurement display and up to three configurable analog outputs.

Its corrosion-resistant IP66 metal enclosure, flexible probe mounting and interchangeable probe design make Indigo300 suitable for humidity, temperature, dew point, CO2, moisture in oil and other demanding industrial measurements.

Vaisala DMT152 - Discontinued
  • Out-of-Stock

The Vaisala DMT152 provides accurate dew-point measurement down to −80 °C Td/f for ultra-dry industrial and OEM applications. This model is discontinued and has been replaced by the Vaisala DMT153.

  • Calibrated dew-point range from −80 to −20 °C Td/f
  • Accuracy up to ±2 °C Td/f
  • Operating pressure up to 50 bar
  • Analog outputs and RS-485 communication
  • DRYCAP® sensor resistant to condensation and contamination
  • Use DMT153 for new projects
Vaisala DMT153 Dew Point Transmitter
  • Out-of-Stock

The Vaisala DMT153 provides traceable low-dew-point measurement for ultra-dry industrial processes. It is the current replacement for the DMT152, with modern analog, Modbus and Vaisala Indigo connectivity.

  • Calibrated dew-point range from −80 to −20 °C Td/f
  • Dew-point accuracy up to ±2 °C Td/f
  • Operating pressure from vacuum to 50 bar absolute
  • Analog outputs or RS-485 with Modbus RTU
  • Compatible with Vaisala Indigo transmitters and Indigo80
  • DRYCAP® sensor with automatic calibration and sensor purge
Dew Point Probe DMP8
  • Out-of-Stock

The Vaisala DRYCAP® Dew Point and Temperature Probe DMP8 provides reliable low-humidity measurement in pressurised pipelines with adjustable installation depth.

  • Dew point measurement range from −70 to +80 °C Td/f
  • Designed for pressurised processes from 0 to 40 bar absolute
  • Adjustable insertion depth with ISO R 1/2 or NPT 1/2 process connection
  • Optional ball-valve kit permits insertion and removal without shutting down the process
  • Use with Modbus RTU, an Indigo transmitter or the portable Indigo80 handheld indicator
Vaisala Indigo510 Indigo520 Malaysia
  • Out-of-Stock

The Vaisala Indigo500 Series provides flagship industrial measurement integration: choose Indigo510 for a simplified single-probe system or Indigo520 for full dual-probe capability.

  • Indigo510: one probe and two isolated analog outputs
  • Indigo520: two probes, four isolated outputs and two relays
  • Ethernet web interface and Modbus TCP communication
  • Rugged IP66 and NEMA 4 metal enclosure
Vaisala Dewpoint Probe DMP1
  • Out-of-Stock

The Vaisala DMP1 Dew Point and Temperature Probe provides fast, dependable low-humidity measurement for dry rooms and moisture-sensitive manufacturing areas.

  • Dew point measurement range from −70 to +80 °C Td/f
  • Fast response for detecting changes across large dry rooms
  • Modbus RTU communication or integration with Vaisala Indigo transmitters
  • Connect to Indigo80 for portable display, data logging, diagnostics and field calibration
  • Suitable for battery production, semiconductor manufacturing and controlled dry environments
Indigo200 Series Transmitters for Vaisala smart probes for Vaisala Smart Probes
  • Out-of-Stock

The Vaisala Indigo200 Series is the standard transmitter platform for one interchangeable Indigo-compatible smart probe, providing local display and practical automation-system connectivity.

  • Indigo201 with three analog outputs and two relays
  • Indigo202 with Modbus RTU and two relays
  • Colour display with numerical and graphical views
  • IP65 enclosure for industrial measurement applications
Vaisala DPT145 SF6 Transmitter | Discontinued
  • Out-of-Stock

The Vaisala DPT145 provides online dew-point, pressure and temperature measurement for SF6-insulated electrical equipment. The model is being discontinued and should not be specified for new projects.

  • Measures dew point, pressure and temperature
  • Calculates SF6 density, normalised pressure and moisture in ppm
  • RS-485 communication with Modbus RTU
  • Contact Seacom for availability and replacement assessment
Vaisala DPT146 Dew Point Transmitter - Discontinued
  • Out-of-Stock

The Vaisala DPT146 combines dew-point and process-pressure measurement in one compact transmitter for compressed-air systems. This model is discontinued and should not be selected for new projects.

  • Dew-point measurement from −70 to +30 °C Td
  • Absolute-pressure measurement from 1 to 12 bar
  • Pressure-compensated dew point and ppm calculation
  • Analog outputs and RS-485 with Modbus RTU
  • Contact Seacom for existing-unit support and replacement assessment
Vaisala DMT132 Dew Point Transmitter | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DMT132 is a compact and economical dew-point transmitter designed to verify refrigerant-dryer performance by measuring the actual outlet-air dew point.

  • Dew-point measurement range from −30 to +50 °C Td/f
  • Accuracy up to ±1 °C in the typical refrigerant-dryer range
  • Two-wire, loop-powered 4–20 mA output
  • Operating pressure up to 20 bar
  • Resistant to condensation and compressor oil
  • Optional warning LED and loop-powered display
Vaisala DMT143 & DMT143L Dew Point Transmitters | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DMT143 and DMT143L provide compact, dependable dew-point measurement for small industrial dryers, compressed-air systems, glove boxes and OEM equipment.

  • Dew-point measurement range across the family from −70 to +60 °C Td/f
  • Accuracy up to ±2 °C Td/f
  • Vaisala DRYCAP® technology with automatic calibration
  • Resistant to condensation, compressor oil and particulate contamination
  • Analog output and RS-485 with Modbus RTU options
  • Compatible with the Vaisala Indigo80 handheld indicator
Vaisala DMP6 High-Temperature Dew Point Probe | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DRYCAP® Dew Point Probe DMP6 measures humidity directly inside very hot industrial processes using a robust probe and passive cooling set.

  • Direct in-line measurement at process temperatures from +100 to +350 °C
  • Dew point measurement range from −25 to +100 °C Td/f
  • Passive cooling requires no power, cooling water or moving components
  • Built-in Modbus RTU or integration with Vaisala Indigo transmitters
  • Connect to Indigo80 for portable display, diagnostics, configuration and field calibration
This website uses cookies to ensure you get the best experience on our website