Smart Humidity and Temperature Probe for wall mounting HMP1 Smart Humidity and Temperature Probe for wall mounting HMP1

Vaisala HMP1 Wall-Mounted Humidity and Temperature Probe

Vaisala HMP1 Wall-Mounted Humidity and Temperature Probe

The Vaisala HMP1 is a high-accuracy, interchangeable humidity and temperature probe for indoor spaces. It connects directly to an Indigo200 or Indigo300 transmitter to create a compact wall-mounted measurement system.

  • Humidity accuracy up to ±1.0% RH
  • Temperature accuracy up to ±0.2 °C
  • 0–100% RH and −40 to +60 °C measurement ranges
  • Modbus RTU and full Vaisala Indigo compatibility

Vaisala HMP1 Wall-Mounted Humidity and Temperature Probe

The Vaisala HMP1 is a high-accuracy, interchangeable humidity and temperature probe for indoor spaces. It connects directly to an Indigo200 or Indigo300 transmitter to create a compact wall-mounted measurement system.

  • Humidity accuracy up to ±1.0% RH
  • Temperature accuracy up to ±0.2 °C
  • 0–100% RH and −40 to +60 °C measurement ranges
  • Modbus RTU and full Vaisala Indigo compatibility

Vaisala HMP1 Humidity and Temperature Probe for Wall Mounting

The Vaisala HUMICAP® Humidity and Temperature Probe HMP1 is designed for accurate ambient measurement in indoor spaces. Its compact probe head and electronics are integrated into one body, making it ideal for wall-mounted monitoring in laboratories, cleanrooms, data centres, museums, storage areas, production rooms and demanding HVAC applications.

The HMP1 provides relative-humidity accuracy up to ±1.0% RH and temperature accuracy up to ±0.2 °C under typical room conditions. It includes a traceable multipoint calibration certificate and uses Vaisala HUMICAP sensor technology for long-term measurement stability.

The probe can operate independently as a Modbus RTU device or connect to a Vaisala Indigo transmitter. When plugged directly into an Indigo200 Series transmitter or Indigo300 transmitter, it forms a neat single-piece wall-mounted system without requiring a probe cable.

Why Choose the Vaisala HMP1?

  • High Indoor Measurement Accuracy: Provides humidity accuracy up to ±1.0% RH and temperature accuracy up to ±0.2 °C at +23 °C.
  • Designed for Indoor Spaces: Optimised for reliable ambient measurement in controlled rooms and occupied indoor environments.
  • Compact Wall Installation: The integrated probe construction can be mounted using the supplied holder or connected directly to Indigo200 and Indigo300 transmitters.
  • Interchangeable Smart Probe: Measurement intelligence and calibration data are stored in the probe, supporting rapid replacement with minimal system downtime.
  • Standalone Modbus RTU: The HMP1 can communicate directly with a building-management system, PLC or other host through RS-485 Modbus RTU.
  • Sensor Purge: Chemical purge helps minimise the effects of cleaning agents and chemical contaminants on long-term measurement stability.
  • Multiple Calculated Parameters: In addition to RH and temperature, the probe calculates dew point, wet-bulb temperature, absolute humidity, enthalpy, mixing ratio and other humidity parameters.
  • Traceable Calibration: Supplied with a traceable calibration certificate covering six humidity points and one temperature point.

HMP1 Measurement Performance

Measurement SpecificationPerformance
Relative-Humidity Range 0–100% RH
RH Accuracy at +23 °C ±1.0% RH from 0–90% RH
RH Factory-Calibration Uncertainty ±0.7% RH from 0–40% RH; ±1.0% RH from 40–95% RH
RH Response Time 21 seconds, T63 in still air
Humidity Sensor Vaisala HUMICAP® I
Temperature Range −40 to +60 °C
Temperature Accuracy at +23 °C ±0.2 °C
Temperature Factory-Calibration Uncertainty ±0.1 °C at +23 °C
Temperature Response Time 70 seconds, T63 in still air

Calculated Humidity Parameters

The HMP1 can provide a wide selection of measured and calculated parameters through its digital interface or a compatible Indigo transmitter.

  • Relative humidity
  • Temperature
  • Absolute humidity
  • Dew point and dew/frost point temperature
  • Wet-bulb temperature
  • Enthalpy
  • Mixing ratio
  • Water-vapour pressure
  • Water concentration and water mass fraction

Operating and Electrical Specifications

FeatureSpecification
Operating Temperature −40 to +60 °C
Storage Temperature −40 to +60 °C
Measurement Environment Air, nitrogen, hydrogen, argon, helium and oxygen; consult Vaisala for other chemicals
Protection Rating IP50
Operating Voltage 15–30 V DC
Typical Current Consumption 2 mA
Maximum Current Consumption 200 mA
Digital Interface Non-isolated RS-485
Communication Protocol Modbus RTU

Mechanical Specifications

Mechanical FeatureSpecification
Connector M12 five-pin A-coded male
Approximate Weight 38 g
Probe Material AISI 316L stainless steel
Probe-Body Material PBT
Probe-Body Diameter 25 mm
Overall Length Approximately 162 mm
Probe-Head Diameter 5 mm
Wall Mounting Probe holder supplied with the HMP1

Compatible Vaisala Indigo Transmitters

Pairing the HMP1 with an Indigo transmitter adds a local display and additional analog, relay, Ethernet or digital communication options, depending on the selected transmitter.

TransmitterRecommended ConfigurationProduct Link
Indigo200 Series Standard compact wall transmitter for one HMP1, with display and practical analog, relay or Modbus options Vaisala Indigo200
Indigo300 Rugged IP66 metal transmitter for one HMP1 with local display and up to three analog outputs Vaisala Indigo300
Indigo510 Simplified flagship transmitter for one probe, isolated outputs, Ethernet and Modbus TCP Vaisala Indigo510
Indigo520 Full flagship transmitter for two compatible probes, isolated outputs, relays, Ethernet and Modbus TCP Vaisala Indigo520

Standalone HMP1 or HMP1 with an Indigo Transmitter?

RequirementRecommended Configuration
Direct Modbus RTU integration HMP1 used as a standalone RS-485 probe
Compact wall display HMP1 connected directly to Indigo200
Rugged metal wall transmitter HMP1 connected directly to Indigo300
Ethernet and one probe HMP1 with Indigo510 and a suitable connection cable
Two measurement probes HMP1 with Indigo520 and suitable connection cables
Portable checking and diagnostics HMP1 connected to an Indigo80 handheld indicator using the appropriate cable

View the Vaisala Indigo80 Portable Meter

Common HMP1 Applications

  • Cleanrooms: Accurate wall-mounted humidity and temperature monitoring in controlled manufacturing environments.
  • Laboratories: Stable ambient measurement for research, testing and calibration areas.
  • Data Centres: Room humidity and temperature measurement for cooling control and environmental monitoring.
  • Museums and Archives: Monitoring indoor conditions around sensitive collections and stored materials.
  • Pharmaceutical Facilities: Environmental measurement in production rooms, warehouses and support areas.
  • HVAC Systems: High-accuracy room input for building automation and indoor climate control.
  • Warehouses: Monitoring conditions affecting moisture-sensitive products and raw materials.
  • Electronics Manufacturing: Humidity control in production, assembly and storage spaces.

Correct Installation for Reliable Room Measurement

  • Install the HMP1 where air can circulate freely around the probe head.
  • Avoid direct sunlight, radiant heat and nearby heat-producing equipment.
  • Do not position the probe directly above doors, windows or air diffusers.
  • Avoid locations affected by external walls or concealed hot and cold services.
  • Mount the probe at a representative height for the monitored space.
  • Use the HMP1 in indoor, non-wetting environments consistent with its IP50 rating.

Calibration and Maintenance

The HMP1 is fully calibrated and adjusted before delivery. The probe stores its own calibration information, allowing it to be exchanged without replacing the complete transmitter. Calibration and adjustment can be performed using Vaisala Insight PC software, a compatible Indigo transmitter or an Indigo80 handheld indicator.

A typical calibration interval is one year, although the correct interval depends on the application, operating conditions and quality-system requirements. Sensor purge can be scheduled or initiated when needed to help remove chemical contamination from the humidity sensor.

Other Vaisala Indigo-Compatible Smart Probes

The HMP1 is one member of the wider Vaisala Indigo smart-probe family. The same Indigo transmitter platform can be configured with different probes for humidity, temperature, dew point, carbon dioxide, moisture in oil and vaporised hydrogen peroxide measurement.

Measurement RequirementRecommended Indigo ProbeTypical Application
General process humidity Vaisala HMP3 General industrial processes with moderate humidity and temperature
High-pressure or vacuum measurement Vaisala HMP4 Compressed air, breathing air, industrial gases and vacuum systems below 100 bar
High-temperature humidity Vaisala HMP5 Ovens, dryers, ceramics, baking and industrial drying processes
Continuous high humidity Vaisala HMP7 High-humidity processes, test chambers, humidifiers and rapid humidity changes
Pressurised pipeline with adjustable insertion Vaisala HMP8 Compressed-air and dryer pipelines up to 40 bar with optional ball-valve installation
Compact and fast-response humidity Vaisala HMP9 Tight spaces, air-handling units, dryers, test chambers and data centres
High-temperature dew point Vaisala DMP5 / DMP6 Industrial drying processes operating at high or very high temperatures
Dew point in a confined space Vaisala DMP7 Dry rooms, compressed-air systems and compact industrial equipment
Pressurised-pipeline dew point Vaisala DMP8 Compressed air and industrial gas pipelines with adjustable insertion depth
Percentage-level carbon dioxide Vaisala GMP251 Incubators, cold storage and demanding life-science applications
ppm-level carbon dioxide Vaisala GMP252 Agriculture, refrigeration, greenhouses and demanding HVAC applications
Industrial temperature only Vaisala TMP1 Pharmaceutical, laboratory, calibration and demanding process-temperature measurement
Moisture in oil Vaisala MMP8 Transformer oil, lubricating oil, hydraulic fluids and oil-condition monitoring
Vaporised hydrogen peroxide Vaisala HPP270 Series Bio-decontamination processes requiring H₂O₂, humidity and temperature measurement
Compatibility note: Probe compatibility and available transmitter functions depend on the selected Indigo model, transmitter firmware and connection arrangement. Confirm the complete probe-and-transmitter configuration when ordering.

Related Vaisala Indoor Humidity Products

Vaisala HMP1 Supplier in Malaysia

Seacom Process Instruments supplies and supports the Vaisala HMP1 humidity and temperature probe in Malaysia for laboratories, cleanrooms, data centres, museums, warehouses, pharmaceutical facilities and demanding HVAC systems.

Our team can assist with selecting the HMP1 as a standalone Modbus probe or configuring it with an Indigo200, Indigo300, Indigo510 or Indigo520 transmitter according to the required display, analog output, relay and network communication functions.

Contact Seacom for Vaisala HMP1 Selection