Cart
Custom content

This is custom content

  • Out-of-Stock
    Atago CM-800α
    Atago PRM
    Atago CM-BASEα

ATAGO Inline Refractometers for Brix & Liquid Concentration

Monitor liquid concentration directly in your process with ATAGO inline refractometers. Models are available for Brix measurement, glycol concentration and other liquid applications requiring a suitable concentration scale.

  • CM-800α: compact inline Brix monitor.
  • PRM-100α DX: wider Brix range, higher Brix accuracy and user-defined concentration scales.
  • CM-800α-PG / EG: dedicated models for propylene glycol or ethylene glycol solutions.
  • Discuss your liquid, concentration range and installation requirements with Seacom Malaysia.

Need advice or a quotation?

Ask Seacom about specifications, availability and the right instrument for your application.

ATAGO Inline Refractometers for Liquid Concentration Monitoring

Is your liquid mixture staying at the required concentration throughout production? ATAGO inline refractometers provide continuous measurements at the installation point, helping operators identify dilution, blending changes and concentration drift while the process is running.

Applications include food and beverage production, glycol cooling circuits and industrial liquid processing. The correct model depends on the liquid, required measuring range, accuracy and process conditions.

What Does an Inline Refractometer Measure?

A refractometer measures refractive index, an optical property that changes with liquid composition. The instrument can express this measurement as Brix or, with a suitable scale, as the concentration of a particular solution.

Brix is based on sucrose concentration. For other liquids, a Brix reading should not automatically be treated as the percentage of the chemical present. A dedicated concentration scale or a validated relationship between refractive index, concentration and temperature is needed.

Which ATAGO Model Suits Your Application?

ModelMeasurement RangePublished AccuracyTypical Selection Reason
CM-800α Brix: 0.0–80.0% Brix: ±0.1% Compact instrument with an integrated display for routine inline Brix monitoring.
PRM-100α DX Brix: 0.00–100.00%
Refractive index: 1.32000–1.55700 nD
Brix: ±0.05%
Refractive index: ±0.00010 nD
Wider measuring range, higher Brix accuracy and user-defined concentration scales. Separate detection and display sections.
CM-800α-PG Propylene glycol: 0.0–90.0% Propylene glycol: ±0.4% Direct concentration monitoring of propylene glycol solutions.
CM-800α-EG Ethylene glycol: 0.0–90.0% Ethylene glycol: ±0.4% Direct concentration monitoring of ethylene glycol solutions.

These figures apply to the stated measurement scales. Confirm the selected configuration and its suitability for your actual liquid before ordering.

Food and Beverage: Check Brix During Production

For beverage blending, syrup preparation and liquid food processing, inline Brix measurement helps operators follow concentration changes during a batch or production run. It can also support checks before filling and help identify the transition between product and rinse water.

The CM-800α is a starting point for routine Brix monitoring. Consider the PRM-100α DX when the application needs its wider range, higher Brix accuracy or separate display arrangement.

Cooling Systems: Monitor Glycol Concentration

Where a cooling circuit uses glycol and water, choose a model matched to the glycol type: CM-800α-PG for propylene glycol or CM-800α-EG for ethylene glycol. Both models also provide a freezing-point scale.

A potential application is checking coolant concentration in a data centre or industrial cooling system that uses a compatible glycol mixture. Share the coolant datasheet, including additives, so the measurement scale and wetted materials can be reviewed against the actual formulation.

Industrial Liquids: Select the Correct Concentration Scale

ATAGO offers dedicated CM-800α variants for selected chemicals, including sodium hydroxide and hydrogen peroxide. The PRM-100α DX also supports user-defined concentration scales using suitable refractive-index, concentration and temperature data.

For cleaning, dilution or chemical blending applications, start with the liquid composition and the concentration you need to control. Where several ingredients can change independently, the reading needs application-specific validation before it is used to control one component.

Connect Measurements to Your Process System

The models listed above provide 4–20 mA and RS-232C outputs. These allow measurements to be passed to compatible recording or control equipment. High- and low-limit alarm outputs are also available on these models.

Automatic temperature compensation is specified from 5 to 100°C for the listed models. This should be distinguished from the instrument's temperature display range and its cleaning-temperature capability.

Installation and Material Selection

The process connection, sample contact and cleaning method are part of selecting the instrument. ATAGO offers different fittings and selected alternative wetted-material versions, including titanium and Hastelloy.

Tell us about deposits or coating on existing equipment. Prism cleaning requirements and suitable cleaning accessories can then be considered together with the installation.

Information to Include with Your Enquiry

  • Liquid name, composition and available datasheet.
  • Normal concentration and required measuring range.
  • Required accuracy and purpose of the measurement.
  • Operating temperature and pressure.
  • Pipe size, connection type or proposed sampling arrangement.
  • Cleaning chemicals, cleaning temperature and frequency.
  • Required output and existing control system.

Discuss Your Liquid Concentration Application with Seacom

Send us the liquid details and what you need to measure. If you already have an instrument, include its model number and a photo of the installation. We can help review the application and identify the model and configuration to quote.

16 other products in the same category:

Vaisala HMP110
  • Out-of-Stock

The Vaisala HMP110 is a high-accuracy humidity and temperature probe designed for demanding equipment integration, environmental chambers, data loggers, incubators and controlled-environment applications.

It provides ±1.5% RH accuracy, a 0–100% RH range, −40 °C to +80 °C temperature measurement, a chemically resistant HUMICAP 180R sensor and analog or Modbus RTU output options.

Vaisala Indigo510 Indigo520 Malaysia
  • Out-of-Stock

The Vaisala Indigo500 Series provides flagship industrial measurement integration: choose Indigo510 for a simplified single-probe system or Indigo520 for full dual-probe capability.

  • Indigo510: one probe and two isolated analog outputs
  • Indigo520: two probes, four isolated outputs and two relays
  • Ethernet web interface and Modbus TCP communication
  • Rugged IP66 and NEMA 4 metal enclosure
Yashima Temperature and Universal Controller
  • Out-of-Stock

Yashima's temperature controller and transmitter accepts 15 type of different input from thermocouple, R.T.D. mA & DC voltage. Range setting & alternation can be easy done from thermocouple to R. T. D. or mA to DC voltage. It has programmable scale range and it is so easy that you may program it within few touches!

Vaisala DMT340 Dewpoint Transmitter | Replaced by Indigo500 and DMP
  • Out-of-Stock

The Vaisala DMT340 Series provided configurable dew-point and temperature measurement for industrial low-humidity applications. The series is discontinued and replaced by Vaisala Indigo500 transmitters with DMP7 or DMP8 smart probes.

  • Former models: DMT341, DMT342, DMT344, DMT347 and DMT348
  • Designed for dry rooms, industrial dryers, compressed air and process gases
  • Legacy display, data logging, analog, relay and communication options
  • Use DMP7 for compact, wall-mounted or tight-space applications
  • Use DMP8 for pressurised processes and pipelines
  • Pair the selected probe with an Indigo500 transmitter
Smart Humidity and Temperature Probe for high temperature HMP5
  • Out-of-Stock

The Vaisala HMP5 provides high-accuracy humidity and temperature measurement in ovens, dryers, kilns and other processes operating at temperatures up to +180 °C.

  • Humidity accuracy up to ±0.8% RH
  • Temperature accuracy up to ±0.1 °C
  • −70 to +180 °C probe-head measurement range
  • Standalone Modbus RTU or Vaisala Indigo transmitter operation
Sekonic ST-50A Thermohygrograph & Alternatives | Seacom
  • Out-of-Stock

The Sekonic ST-50A displays temperature and relative humidity and records both on a continuous paper chart.

  • Electronic temperature and humidity sensing with LCD display.
  • Optional extension cables for remote sensor placement.
  • Battery operation or a suitable external DC supply.
  • Desktop or wall-mounted installation.

Being phased out: confirm availability before ordering. Alternatives include the Sato Sigma II for paper records, Sato SK-L754 for electronic logging and Vaisala viewLinc for centralised monitoring.

Fine Flexible Probe SF Series
  • Out-of-Stock

Anritsu SF Series fine flexible temperature probes use extra-fine thermocouple wire in a Teflon-coated sheath for internal temperature measurement.

  • Flexible construction for positioning in restricted spaces
  • Type K and Type E configurations
  • Published temperature range: −50 to 200°C
  • Model references: SF-K-050, SF-K-100, SF-K-150 and SF-K-200
  • Confirm the required length and instrument connector when ordering
Smart Dew Point Probe and Transmitter DMP7
  • Out-of-Stock

The Vaisala DRYCAP® Dew Point and Temperature Probe DMP7 is designed for accurate low-humidity measurement where installation space is limited.

  • Short 41 mm probe for remote installation in tight spaces
  • Dew point measurement range from −70 to +80 °C Td/f
  • Pressure-tight installation for processes from 0 to 10 bar
  • Use with Modbus RTU, an Indigo transmitter or the portable Indigo80 handheld indicator
  • Suitable for dry rooms, compressed air, industrial drying and semiconductor equipment
Vaisala DMT132 Dew Point Transmitter | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DMT132 is a compact and economical dew-point transmitter designed to verify refrigerant-dryer performance by measuring the actual outlet-air dew point.

  • Dew-point measurement range from −30 to +50 °C Td/f
  • Accuracy up to ±1 °C in the typical refrigerant-dryer range
  • Two-wire, loop-powered 4–20 mA output
  • Operating pressure up to 20 bar
  • Resistant to condensation and compressor oil
  • Optional warning LED and loop-powered display
Vaisala MMP8 Moisture in Oil Probe | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala MMP8 provides continuous online measurement of dissolved moisture and temperature in transformer oil, lubrication oil, hydraulic fluid and other liquid hydrocarbons.

  • Measures water activity from 0 to 1 aw, relative saturation, temperature and ppmw
  • Dry-end accuracy up to ±0.01 aw or ±1%RS
  • Temperature measurement from −40 to +180 °C
  • Available in standard 262 mm and long 448 mm probe versions
  • Adjustable insertion depth with ISO 1/2 or NPT 1/2 process fittings
  • Standalone Modbus RTU or connection to Vaisala Indigo transmitters
Tokico Flow Meter Malaysia FGB FRO FRP | Seacom
  • Out-of-Stock

The Tokico FGB, FRO and FRP are high-accuracy mechanical positive displacement flow meters for measuring diesel, kerosene, fuel oil, heavy oil, crude palm oil and other compatible industrial liquids.

Available in sizes from 15 to 100 mm, these durable Tokico flow meters provide direct mechanical totalisation, accuracy within ±0.5% and flow capacities ranging from small-volume fuel consumption to large oil-transfer applications.

FUJIFILM Prescale Pressure Film | Seacom
  • Out-of-Stock

FUJIFILM Prescale reveals contact pressure and pressure distribution through changes in red colour density. Place the film between contacting surfaces to identify uneven loading and compare contact patterns.

  • Nine standard grades covering 0.006 to 300 MPa
  • Two-sheet and mono-sheet types, depending on the grade
  • For pressure checks on rollers, flanges, gaskets, presses and contact surfaces
  • Choose the grade according to pressure, temperature and humidity conditions
ickson PR Series Pressure Data Logger | PR125 PR325 PR525
  • Out-of-Stock

The Dickson PR125, PR325 and PR525 are rugged battery-powered pressure data loggers for recording equipment and line pressure without a permanently connected computer.

  • PR125: 0 to 100 PSI pressure range
  • PR325: 0 to 300 PSI pressure range
  • PR525: 0 to 500 PSI pressure range
  • Pressure accuracy of ±1% of full scale
  • User-selectable sampling from 1 second to 24 hours
  • Segmented LCD with current and minimum/maximum readings
  • IP68 enclosure with 1/4-inch NPT process fitting
  • USB or flash-card data-retrieval configurations
Dew Point Probe DMP8
  • Out-of-Stock

The Vaisala DRYCAP® Dew Point and Temperature Probe DMP8 provides reliable low-humidity measurement in pressurised pipelines with adjustable installation depth.

  • Dew point measurement range from −70 to +80 °C Td/f
  • Designed for pressurised processes from 0 to 40 bar absolute
  • Adjustable insertion depth with ISO R 1/2 or NPT 1/2 process connection
  • Optional ball-valve kit permits insertion and removal without shutting down the process
  • Use with Modbus RTU, an Indigo transmitter or the portable Indigo80 handheld indicator
Vaisala HMP8
  • Out-of-Stock

The Vaisala HMP8 provides high-accuracy humidity and temperature measurement in compressed air, refrigerant dryers and pressurised industrial processes up to 40 bar.

  • Humidity accuracy up to ±0.8% RH
  • Operating pressure from vacuum to 40 bar
  • Adjustable insertion depth with two probe lengths
  • Optional ball valve for insertion and removal under process conditions
This website uses cookies to ensure you get the best experience on our website