Cart
Custom content

This is custom content

  • Out-of-Stock
    Vaisala HMT360 Intrinsically Safe Transmitter | HMT370EX Replacement

Vaisala HMT360 Intrinsically Safe Humidity and Temperature Transmitter – Discontinued

The Vaisala HMT360 Series was an intrinsically safe transmitter platform for humidity, temperature and moisture measurement in hazardous areas. It is discontinued and replaced by the Vaisala HMT370EX with an application-specific probe.

  • HMT361 wall mounting → HMP371
  • HMT363 ducts and confined spaces → HMP373
  • HMT364 high pressure and vacuum → HMP374
  • HMT365 high temperature → HMP375
  • HMT367 high humidity → HMP377
  • HMT368 pressurised pipelines → HMP378

Need advice or a quotation?

Ask Seacom about specifications, availability and the right instrument for your application.

Product status: The Vaisala HMT360 Series is discontinued. For new hazardous-area installations and planned migrations, use the Vaisala HMT370EX intrinsically safe transmitter with the probe and regional certification selected for the application.

Vaisala HMT360 for Existing Hazardous-Area Installations

The Vaisala HMT360 Series provided intrinsically safe humidity and temperature measurement for potentially explosive gas and dust environments. Different probe versions supported wall mounting, confined spaces, high pressure, vacuum, high temperature, high humidity and pressurised pipelines.

Configuration-dependent versions also measured moisture in industrial oil, JET A-1 fuel and natural gas. The transmitter used two-wire 4–20 mA measurement channels through an approved intrinsic-safety interface, with service communication used for configuration and calibration.

HMT360 to HMT370EX Replacement Guide

Legacy modelOriginal applicationCurrent HMT370EX probeMigration note
HMT361 Wall-mounted ambient measurement HMP371 Fixed probe for wall or enclosure installation
HMT363 Ducts, channels and confined spaces HMP373 Check probe cable material, insertion depth and temperature class
HMT364 High-pressure processes and vacuum HMP374 Confirm process pressure, fitting and safe isolation arrangement
HMT365 High-temperature processes HMP375 Check probe-head temperature against the required Ex temperature class
HMT367 Continuous high humidity and demanding wet conditions HMP377 Review probe heating and external temperature compensation requirements
HMT368 Pressurised pipelines HMP378 Confirm insertion depth, fitting body and ball-valve arrangement

Explore the Vaisala HMT370EX replacement platform

Special HMT360 Moisture and Natural-Gas Versions

Legacy configurationOriginal medium or useCurrent starting pointImportant requirement
HMT368F / HMT360F Moisture in industrial oil HMT370EX with HMP378F Confirm oil type, water-solubility coefficients, process fitting and certification
HMT368H / HMT360H Moisture in JET A-1 fuel HMT370EX with HMP378H Confirm aviation-fuel application, installation and applicable approval
HMT362N Natural gas with a flanged probe arrangement Application review required Do not assume a current standard probe duplicates the legacy flange and certification
HMT364N High-pressure natural gas HMT370EX with HMP374 as the technical starting point Gas compatibility, pressure, process sealing and hazardous-area approval must be confirmed
HMT368N Natural-gas pipeline installation HMT370EX with HMP378 as the technical starting point Confirm gas service, pipeline pressure, insertion method, fitting and certification

Special-medium warning: a similar probe shape or pressure rating does not by itself approve a replacement for natural gas, oil or aviation fuel. The measured medium, complete Ex marking, sealing materials, pressure boundary and regional certification must be reviewed for the exact ordered configuration.

HMT360 and HMT370EX Comparison

Comparison pointHMT360 SeriesHMT370EX Series
Product status Discontinued Current replacement platform
Safety concept Intrinsically safe legacy transmitter Current intrinsically safe Ex i transmitter
Probe options HMT361, HMT363, HMT364, HMT365, HMT367 and HMT368 variants Interchangeable HMP371, HMP373, HMP374, HMP375, HMP377 and HMP378 probes
Special moisture versions Oil, JET A-1 and selected natural-gas configurations HMP378F for oil and HMP378H for JET A-1; natural gas requires application review
Relative-humidity range 0 to 100 %RH 0 to 100 %RH within model and dew-point limitations
Best stated RH accuracy Up to ±1.0 %RH at +20 °C Up to ±0.8 %RH at +23 °C
Temperature measurement Probe-dependent, up to −70 to +180 °C Probe- and certification-dependent, up to −70 to +180 °C
Analogue outputs Two-wire 4–20 mA, configuration-dependent Two configurable two-wire 4–20 mA channels
Probe servicing Legacy removable-probe arrangement Interchangeable smart probes with independent calibration
Ingress protection IP65 legacy enclosure Up to IP66 with the probe connected; configuration-dependent

Hazardous-Area Migration Checks

Replacing an intrinsically safe transmitter requires more than matching the measured parameter. Review the complete electrical and mechanical installation before changing the device.

  • Record the complete HMT360 model code, Ex marking and certification documents.
  • Confirm the gas or dust zone, gas group, dust group and required equipment protection level.
  • Check the required temperature class and maximum ambient and process temperatures.
  • Verify the safety barrier or galvanic isolator against the HMT370EX entity parameters.
  • Include field-cable capacitance, inductance and cable length in the intrinsic-safety assessment.
  • Confirm whether one or two 4–20 mA measurement channels are required.
  • Map the existing measurement ranges, engineering units and receiving-system scaling.
  • Check probe fitting, pressure rating, insertion depth, sealing materials and removal procedure.
  • Select the correct regional certificate for the country where the equipment will be installed.

Probe Temperature and Ex Temperature Class

The maximum measuring range of a probe is not automatically the permitted temperature in every hazardous-area installation. The allowed temperature depends on the probe model, cable material, gas or dust classification and required Ex temperature class.

Example temperature classPublished upper probe-head limit for applicable configurationsSelection guidance
T6 Approximately +55 °C Use the exact limit stated in the regional safety guide and ordered configuration
T5 Approximately +100 °C Applicable probe and cable configuration must be confirmed
T4 Up to approximately +135 °C for applicable remote probes Do not use the general probe range as the certified limit
T3 Up to +180 °C for applicable probe configurations Confirm the complete Ex approval, ambient conditions and installation method

Can an Existing HMT360 Remain in Service?

A functioning HMT360 does not need to be removed solely because the series is discontinued. Keep the transmitter label, probe model, barrier information, control drawing, wiring diagram, calibration certificates and configuration records while the installation remains in service.

For a critical hazardous-area measurement, check calibration and repair availability and plan migration before a failure creates an extended process interruption. Any service work must preserve the approved intrinsic-safety installation and be carried out by suitably competent personnel.

Vaisala HMT360 Support and HMT370EX Replacement in Malaysia

Seacom Process Instruments supports existing Vaisala HMT360 intrinsically safe transmitters in Malaysia and supplies the current HMT370EX platform for chemical production, pharmaceuticals, paint booths, powder handling, fuel storage, oil and gas processes and other hazardous areas.

Our team can assist with identifying the legacy probe, selecting the HMT370EX configuration, reviewing process fittings and pressure limits, mapping 4–20 mA outputs, coordinating safety barriers, commissioning and calibration planning.

Contact Seacom with the complete HMT360 model code, nameplate photographs, hazardous-area classification, measured medium, process temperature and pressure, existing barrier details and required outputs so we can review a suitable migration arrangement.

Product documents

Catalogues, manuals and other files available for this instrument.

HMT370EX catalogue

Intrinsically Safe Humidity and Temperature Transmitter Series HMT370EX

999.79KB
Download

HMT360 catalogue

Instrinsically Safe Humidity and Humidity Transmitter HMT360 series

1.17MB
Download

You might also like

Vaisala HMT370EX Intrinsically Safe Transmitter | Seacom
  • Out-of-Stock

The Vaisala HMT370EX provides intrinsically safe humidity and temperature measurement with HMP-series probes. The new DMP370 configuration combines the HMT370EX transmitter with a DMP37X DRYCAP® probe for low-dew-point measurement in hazardous locations.

  • HMP probes for relative humidity and temperature
  • DMP370 dew-point measurement from −70 to +10 °C Td/f
  • Two two-wire 4–20 mA outputs
  • Certified configurations for hazardous gas and dust areas, up to Zone 0 / 20
  • Detachable probes and traceable calibration

DMP370 availability: Vaisala plans first deliveries for Q1 2027. Contact Seacom for configuration and project lead time.

16 other products in the same category:

Vaisala HMM105 Digital Humidity Module | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala HMM105 provides reliable humidity measurement for integration into environmental chambers, incubators and OEM equipment.

  • 0–100% RH measurement range
  • I2C output for relative humidity or dew point
  • Detachable 12 mm probe with 300 mm flexible cable
  • Probe withstands +180 °C continuously and +200 °C temporarily
Indigo200 Series Transmitters for Vaisala smart probes for Vaisala Smart Probes
  • Out-of-Stock

The Vaisala Indigo200 Series is the standard transmitter platform for one interchangeable Indigo-compatible smart probe, providing local display and practical automation-system connectivity.

  • Indigo201 with three analog outputs and two relays
  • Indigo202 with Modbus RTU and two relays
  • Colour display with numerical and graphical views
  • IP65 enclosure for industrial measurement applications
Vaisala Indigo510 Indigo520 Malaysia
  • Out-of-Stock

The Vaisala Indigo500 Series provides flagship industrial measurement integration: choose Indigo510 for a simplified single-probe system or Indigo520 for full dual-probe capability.

  • Indigo510: one probe and two isolated analog outputs
  • Indigo520: two probes, four isolated outputs and two relays
  • Ethernet web interface and Modbus TCP communication
  • Rugged IP66 and NEMA 4 metal enclosure
Vaisala HMT370EX Intrinsically Safe Transmitter | Seacom
  • Out-of-Stock

The Vaisala HMT370EX provides intrinsically safe humidity and temperature measurement with HMP-series probes. The new DMP370 configuration combines the HMT370EX transmitter with a DMP37X DRYCAP® probe for low-dew-point measurement in hazardous locations.

  • HMP probes for relative humidity and temperature
  • DMP370 dew-point measurement from −70 to +10 °C Td/f
  • Two two-wire 4–20 mA outputs
  • Certified configurations for hazardous gas and dust areas, up to Zone 0 / 20
  • Detachable probes and traceable calibration

DMP370 availability: Vaisala plans first deliveries for Q1 2027. Contact Seacom for configuration and project lead time.

Vaisala HMP110
  • Out-of-Stock

The Vaisala HMP110 is a high-accuracy humidity and temperature probe designed for demanding equipment integration, environmental chambers, data loggers, incubators and controlled-environment applications.

It provides ±1.5% RH accuracy, a 0–100% RH range, −40 °C to +80 °C temperature measurement, a chemically resistant HUMICAP 180R sensor and analog or Modbus RTU output options.

Vaisala HMT140 Replacement with RFL100 | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala HMT140 Wi-Fi Data Logger has been discontinued and is no longer recommended for new monitoring systems.

  • Primary replacement: Vaisala RFL100 with AP10 VaiNet Access Point
  • Existing HMT140 installations can continue to be supported
  • Migration should be checked against the existing sensor and input type
  • Contact Seacom for replacement selection and viewLinc compatibility
Smart Humidity and Temperature Probe for high temperature HMP5
  • Out-of-Stock

The Vaisala HMP5 provides high-accuracy humidity and temperature measurement in ovens, dryers, kilns and other processes operating at temperatures up to +180 °C.

  • Humidity accuracy up to ±0.8% RH
  • Temperature accuracy up to ±0.1 °C
  • −70 to +180 °C probe-head measurement range
  • Standalone Modbus RTU or Vaisala Indigo transmitter operation
Biogas Methane, Carbon Dioxide and Humidity Multigas Probe MGP261
  • Out-of-Stock

The Vaisala MGP261 measures methane, carbon dioxide and humidity directly in raw biogas. Its in-situ design avoids a separate sampling system and helps operators monitor gas quality while protecting downstream equipment.

  • Measures CH4, CO2 and water vapour in one probe
  • 0–100 vol-% measurement range for methane and carbon dioxide
  • Humidity output as 0–25 vol-% H2O or −10 to +60 °C dew point
  • Heated optics help prevent condensation in wet biogas
  • Three isolated 4–20 mA outputs and RS-485 Modbus RTU
  • Ex-certified construction for direct installation in hazardous process areas

Ask Seacom about the MGP261

Smart Humidity and Temperature Probe for high pressure HMP4
  • Out-of-Stock

The Vaisala HMP4 provides high-accuracy humidity and temperature measurement in compressed air, breathing air, industrial gases, vacuum systems and other processes operating at pressures up to 100 bar.

  • Operating pressure below 100 bar, including vacuum applications
  • Humidity accuracy up to ±0.8% RH
  • Temperature range from -70 °C to +180 °C
  • Standalone Modbus RTU or connection to an Indigo transmitter
Vaisala HMP7
  • Out-of-Stock

The Vaisala HMP7 is designed for continuously humid, rapidly changing and near-condensing environments. Probe heating helps prevent condensation while maintaining reliable process measurement.

  • Humidity accuracy up to ±0.8% RH
  • Probe heating for condensation prevention
  • −70 to +180 °C probe-head measurement range
  • Standalone Modbus RTU or Vaisala Indigo transmitter operation
Vaisala Indigo520 Supervisor
  • Out-of-Stock

The Vaisala Indigo520 Supervisor manages up to 100 compatible compact humidity and temperature probes through one host unit. It provides local visibility for the maintenance team and Modbus TCP communication for data centre BMS integration.

  • Two daisy chains: Up to 50 probes per chain.
  • 5-inch touchscreen: View measurements, probe status and alerts.
  • Web interface: Supports commissioning and configuration.
  • Malaysia project support: Contact Seacom for probe selection and installation requirements.

Expected availability: early 2027. Enquire with Seacom for configuration and delivery confirmation.

Vaisala Humidity And Temperature Transmitter XMP10
  • Out-of-Stock

The Vaisala XMP10 Series comprises compact humidity and temperature probes offering accuracy levels up to ±1% RH and ±0.1 °C for demanding HVAC, data-centre and critical-environment applications.

The probes feature analog or Modbus RTU outputs, a standard M8 connector, an IP65-rated body and compatibility with Vaisala Origo10 modular HVAC transmitters.

CO2, Temperature and Humidity Transmitter Series GMW90
  • Out-of-Stock

The Vaisala GMW90 Series provides stable wall-mounted carbon-dioxide and temperature measurement, with optional humidity, for demanding HVAC and building-automation applications.

  • Carbon-dioxide measurement from 0 to 5000 ppm
  • CO₂ accuracy up to ±(30 ppm + 2% of reading)
  • Temperature measurement from −5 to +55 °C
  • Optional HUMICAP® relative-humidity measurement from 0 to 95 %RH
  • Voltage, current or Modbus RTU output models
  • Display and CO₂ status-indicator options
  • Field-exchangeable calibrated measurement modules
  • Traceable three-point CO₂ calibration certificate included
Vaisala HMT330 Transmitter| Indigo500 Replacement
  • Out-of-Stock

The Vaisala HMT330 Series was a flagship industrial transmitter platform for humidity, temperature and calculated moisture parameters. It is discontinued and replaced by an Indigo500 transmitter with the HMP probe selected for the application.

  • HMT331 wall mounting → HMP1 with Indigo500
  • HMT333 ducts and tight spaces → HMP3 or HMP9 with Indigo500
  • HMT334 high pressure and vacuum → HMP4 with Indigo500
  • HMT335 high temperature → HMP5 with Indigo500
  • HMT337 high humidity → HMP7 with Indigo500
  • HMT338 pressurised pipelines → HMP8 with Indigo500
This website uses cookies to ensure you get the best experience on our website