Cart
Custom content

This is custom content

  • Out-of-Stock
    Vaisala HMT140 Replacement with RFL100 | Vaisala Distributor Malaysia | Seacom

Vaisala HMT140 Wi-Fi Data Logger – Discontinued, Replaced by RFL100

The Vaisala HMT140 Wi-Fi Data Logger has been discontinued and is no longer recommended for new monitoring systems.

  • Primary replacement: Vaisala RFL100 with AP10 VaiNet Access Point
  • Existing HMT140 installations can continue to be supported
  • Migration should be checked against the existing sensor and input type
  • Contact Seacom for replacement selection and viewLinc compatibility

Need advice or a quotation?

Ask Seacom about specifications, availability and the right instrument for your application.

Vaisala HMT140 Wi-Fi Data Logger — Discontinued

Product status: The Vaisala HMT140 has been discontinued. For new wireless temperature and humidity monitoring systems, use the Vaisala RFL100 Wireless Data Logger with AP10 Access Point. Existing HMT140 users should confirm the installed input type before selecting a replacement.

The HMT140 was a battery-powered Wi-Fi data logger for use with the Vaisala viewLinc Continuous Monitoring System. Depending on the model, it could measure relative humidity, temperature, RTD inputs, voltage, current or Boolean contacts.

This page remains available to help existing users identify installed HMT140 models, maintain operating systems and plan migration to current Vaisala monitoring hardware.

Recommended Replacement

Existing HMT140 ApplicationRecommended Direction
Temperature and relative humidity RFL100 with AP10
Refrigerator, freezer or cold-room temperature RFL100 with a suitable temperature probe
CO₂, temperature and humidity RFL100 with compatible probes and AP10
Voltage, current or Boolean input Application review required; a VDL200 or another viewLinc-compatible interface may be more suitable

The RFL100 uses Vaisala VaiNet rather than the HMT140’s direct Wi-Fi connection. Each installation therefore requires an AP10 Access Point and a check of wireless coverage, probe compatibility and viewLinc version.

HMT140 Model Identification

Legacy ModelMeasurement Channels
HMT141 1 temperature and 1 relative-humidity channel using an HMP110 probe
HMT143 2 RTD temperature channels
HMT144 2 voltage inputs, 0–5 V DC
HMT145 2 voltage inputs, 0–10 V DC
HMT146 2 current inputs, 0–20 mA
HMT147 2 Boolean or door-contact inputs
HMT148 1 RTD temperature input and 1 Boolean input
HMT14D 1 RTD temperature input and 1 current input
HMT14E 1 RTD temperature input and 1 voltage input, 0–5 V DC
HMT14F 1 RTD temperature input and 1 voltage input, 0–10 V DC

Legacy HMT140 Measurement Performance

MeasurementLegacy Specification
Relative humidity 0–100% RH using the HMP110 probe
HMP110 temperature −40 to +80 °C
RTD temperature input −196 to +90 °C
Current input 0–22 mA measurement range
Voltage input 0–5 V or 0–10 V, depending on model
Contact input Open/closed dry contact

Legacy Technical Specifications

Wireless network IEEE 802.11b/g Wi-Fi
Wi-Fi security WEP 128-bit, WPA or WPA2 Personal
Memory 3,060 samples
Sample interval User selectable from 2 to 60 minutes
Display Optional 128 × 64 monochrome display without backlight
Housing protection IP65
Operating temperature without display −40 to +60 °C
Operating temperature with display −20 to +60 °C
Weight 300 g with batteries, without probe

HMT140 and RFL100 Comparison

FeatureLegacy HMT140Current RFL100 System
Wireless technology Direct 2.4 GHz Wi-Fi VaiNet wireless through AP10
Primary measurements Model-dependent temperature, RH, analog or contact inputs Temperature, RH and CO₂ using compatible probes
Network connection Each logger connects to the Wi-Fi network AP10 connects the VaiNet devices to the network
Local measurement memory 3,060 samples 30 days of local measurement storage
Product status Discontinued Current wireless viewLinc platform

Migration Checklist for Existing HMT140 Users

  • Record the complete HMT140 model number and installed channel type.
  • Confirm the measurement range, required accuracy and existing probe arrangement.
  • Check whether temperature, humidity, analog or door-contact inputs are being used.
  • Confirm the installed viewLinc version and server environment.
  • Review the location of existing Wi-Fi access points and the proposed AP10 installation.
  • Carry out a VaiNet coverage assessment where walls, cold-room panels or production equipment may affect the signal.
  • Plan calibration, qualification and change-control documentation before replacing devices in a regulated system.

Vaisala HMT140 Replacement and viewLinc Support in Malaysia

Seacom Process Instruments supports existing Vaisala HMT140 installations in Malaysia and supplies current Vaisala RFL100, AP10 and VDL200 monitoring hardware for pharmaceutical facilities, laboratories, hospitals, blood banks, warehouses, cold rooms and other controlled environments.

Our team can assist with installed-model identification, replacement selection, monitoring-point planning, VaiNet coverage assessment, network architecture, viewLinc integration, installation, commissioning, calibration planning and GxP validation documentation.

Contact Seacom with the HMT140 model number, measured parameters, probe details, device quantities, facility layout, network constraints and validation requirements for a suitable migration plan.

Product documents

Catalogues, manuals and other files available for this instrument.

HMT140 catalogue

Wi-Fi Data Logger (CMS, FDA Approved) HMT140

477.89KB
Download

You might also like

Temperature Data Loggers DL1016/1416 (CMS, FDA Approved)
  • Out-of-Stock

Vaisala DL1000, DL1400, DL1016 and DL1416 temperature data loggers provide reliable, traceable monitoring for refrigerators, freezers, cold rooms, incubators and regulated facilities.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Current replacement platform: Vaisala VDL200 with suitable smart probes
  • Two- or four-channel configurations
  • External probe range down to −90 °C
  • Onboard memory and a typical 10-year battery life
Thermocouple Data Loggers DL1700 (CMS, FDA Approved)
  • Out-of-Stock

The Vaisala DL1700 is a four-channel thermocouple data logger for continuous monitoring and validation work at extreme temperatures.

  • Overall application range from −240 to +1760 °C, depending on thermocouple type
  • Accepts J, K, T, E, R and S thermocouples
  • Four thermocouple inputs plus an internal cold-junction reference
  • Works with Vaisala viewLinc for monitoring, alarms and compliant reporting
Temperature And RH Data Logger (CMS, FDA Approved) DL2000
  • Out-of-Stock

The Vaisala DL2000 combines precision temperature and relative-humidity monitoring with optional analog or door-contact inputs for viewLinc systems.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Current replacement platform: Vaisala VDL200 with suitable smart probes
  • Internal temperature and relative-humidity measurement
  • Optional current, voltage or Boolean input configurations
  • Onboard memory and a typical 10-year battery life
Vaisala DL4000 Universal Data Logger | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DL4000 records current or voltage signals from industrial transmitters and brings pressure, flow, level, pH, moisture, gas concentration and other process measurements into viewLinc.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Closest current substitute: Vaisala VDL200 with ANP115 analog input probe
  • Available with 1, 2 or 4 analog input channels
  • Supports 0–20 mA, 0–5 V DC or 0–10 V DC models
  • 120,000-sample onboard memory and a 10-year battery
Vaisala HMT140 Replacement with RFL100 | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala HMT140 Wi-Fi Data Logger has been discontinued and is no longer recommended for new monitoring systems.

  • Primary replacement: Vaisala RFL100 with AP10 VaiNet Access Point
  • Existing HMT140 installations can continue to be supported
  • Migration should be checked against the existing sensor and input type
  • Contact Seacom for replacement selection and viewLinc compatibility
Long Range Wireless Data Logger (CMS, FDA Approved) RFL100
  • Out-of-Stock

The Vaisala RFL100 uses secure, long-range VaiNet wireless technology to monitor temperature, relative humidity and carbon dioxide with the AP10 Access Point and viewLinc Continuous Monitoring System.

  • At least 50 m typical indoor wireless range
  • Up to 32 RFL100 data loggers per AP10
  • 30 days of local measurement memory
  • Approximately 18 months of battery operation for temperature and humidity monitoring
Vaisala Temperature and Humidity Logger VDL200
  • Out-of-Stock

The Vaisala VDL200 is a secure Power-over-Ethernet data logger for monitoring temperature, relative humidity, carbon dioxide and analog or Boolean inputs in controlled and GxP-regulated environments.

Designed for the Vaisala viewLinc Continuous Monitoring System, the VDL200 combines interchangeable smart probes, onboard memory and battery backup to provide reliable, gap-free environmental monitoring.

Vaisala Continuous Monitoring System viewLinc
  • Out-of-Stock

Vaisala viewLinc provides continuous monitoring, alarming and reporting for temperature, humidity, CO₂, differential pressure and other critical parameters in GxP-regulated and demanding industrial environments.

  • Supports FDA 21 CFR Part 11 and EU GMP Annex 11 requirements
  • Secure audit trails, access control, alarms and reports
  • Ethernet, PoE, Wi-Fi, VaiNet and Modbus connectivity
  • Scalable from a few monitoring points to thousands

9 other products in the same category:

Long Range Wireless Data Logger (CMS, FDA Approved) RFL100
  • Out-of-Stock

The Vaisala RFL100 uses secure, long-range VaiNet wireless technology to monitor temperature, relative humidity and carbon dioxide with the AP10 Access Point and viewLinc Continuous Monitoring System.

  • At least 50 m typical indoor wireless range
  • Up to 32 RFL100 data loggers per AP10
  • 30 days of local measurement memory
  • Approximately 18 months of battery operation for temperature and humidity monitoring
Vaisala Continuous Monitoring System viewLinc
  • Out-of-Stock

Vaisala viewLinc provides continuous monitoring, alarming and reporting for temperature, humidity, CO₂, differential pressure and other critical parameters in GxP-regulated and demanding industrial environments.

  • Supports FDA 21 CFR Part 11 and EU GMP Annex 11 requirements
  • Secure audit trails, access control, alarms and reports
  • Ethernet, PoE, Wi-Fi, VaiNet and Modbus connectivity
  • Scalable from a few monitoring points to thousands
Thermocouple Data Loggers DL1700 (CMS, FDA Approved)
  • Out-of-Stock

The Vaisala DL1700 is a four-channel thermocouple data logger for continuous monitoring and validation work at extreme temperatures.

  • Overall application range from −240 to +1760 °C, depending on thermocouple type
  • Accepts J, K, T, E, R and S thermocouples
  • Four thermocouple inputs plus an internal cold-junction reference
  • Works with Vaisala viewLinc for monitoring, alarms and compliant reporting
Temperature Data Loggers DL1016/1416 (CMS, FDA Approved)
  • Out-of-Stock

Vaisala DL1000, DL1400, DL1016 and DL1416 temperature data loggers provide reliable, traceable monitoring for refrigerators, freezers, cold rooms, incubators and regulated facilities.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Current replacement platform: Vaisala VDL200 with suitable smart probes
  • Two- or four-channel configurations
  • External probe range down to −90 °C
  • Onboard memory and a typical 10-year battery life
Temperature And RH Data Logger (CMS, FDA Approved) DL2000
  • Out-of-Stock

The Vaisala DL2000 combines precision temperature and relative-humidity monitoring with optional analog or door-contact inputs for viewLinc systems.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Current replacement platform: Vaisala VDL200 with suitable smart probes
  • Internal temperature and relative-humidity measurement
  • Optional current, voltage or Boolean input configurations
  • Onboard memory and a typical 10-year battery life
Vaisala PDT101 PDT102 Pressure Transmitter | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala PDT101 and PDT102 provide precise low differential-pressure measurement for cleanrooms, isolation rooms, regulated facilities, data centres and air-handling systems.

  • PDT101 accuracy up to 0.40% of span
  • PDT102 high accuracy up to 0.25% of span
  • 4–20 mA or voltage output configurations
  • Compatible with Vaisala viewLinc monitoring solutions
Cabinet for Continuous Monitoring System (CMS)
  • Out-of-Stock

The Vaisala CAB100 centralises differential-pressure transmitters, analog inputs and interface components for cleanroom and industrial monitoring with the viewLinc Continuous Monitoring System.

  • Preconfigured cabinet for viewLinc monitoring systems
  • CAB100A and higher-capacity CAB100B models
  • Differential pressure, analog input and hazardous-area options
  • IP54 or IP66 enclosure protection, depending on model
Vaisala DL4000 Universal Data Logger | Vaisala Distributor Malaysia | Seacom
  • Out-of-Stock

The Vaisala DL4000 records current or voltage signals from industrial transmitters and brings pressure, flow, level, pH, moisture, gas concentration and other process measurements into viewLinc.

  • Scheduled for future discontinuation; confirm availability before specifying
  • Closest current substitute: Vaisala VDL200 with ANP115 analog input probe
  • Available with 1, 2 or 4 analog input channels
  • Supports 0–20 mA, 0–5 V DC or 0–10 V DC models
  • 120,000-sample onboard memory and a 10-year battery
Vaisala Temperature and Humidity Logger VDL200
  • Out-of-Stock

The Vaisala VDL200 is a secure Power-over-Ethernet data logger for monitoring temperature, relative humidity, carbon dioxide and analog or Boolean inputs in controlled and GxP-regulated environments.

Designed for the Vaisala viewLinc Continuous Monitoring System, the VDL200 combines interchangeable smart probes, onboard memory and battery backup to provide reliable, gap-free environmental monitoring.

This website uses cookies to ensure you get the best experience on our website