The Vaisala GMP231 is an OEM carbon-dioxide probe designed for accurate measurement and permanent wall installation in life-science incubators.
The Vaisala GMP231 is designed specifically for incubator manufacturers and equipment integrators. It installs through the incubator wall so the CARBOCAP® sensor head is exposed to the chamber while the electronics remain outside and thermally isolated.
This construction allows the probe to remain installed during high-temperature sterilisation, reducing the need to remove and separately decontaminate the sensor. The measurement is optimized around the common 5% CO₂ incubator setpoint while covering concentrations from 0 to 20% CO₂.
Incubator-specific design: Select GMP231 when the probe must be integrated through an incubator wall and remain in place during +180 °C heat sterilisation. For a general-purpose percentage-level probe with analogue, Modbus RTU and Indigo-transmitter options, review the Vaisala GMP251.
| Specification | GMP231 |
|---|---|
| Measurement range | 0 to 20% CO₂ |
| Optimized measurement point | 5% CO₂ |
| Calibration uncertainty at 5% CO₂ | ±0.1% CO₂ |
| Repeatability from 0 to 8% CO₂ | ±0.1% CO₂ |
| Repeatability from 8 to 12% CO₂ | ±0.2% CO₂ |
| Repeatability from 12 to 20% CO₂ | ±0.4% CO₂ |
| Non-linearity from 0 to 20% CO₂ | ±0.1% CO₂ |
| Start-up time | Less than 20 seconds |
| Warm-up time for full specification | Less than three minutes |
| Response time | Less than 30 seconds, T63; less than 50 seconds, T90 |
| Sensor technology | Vaisala CARBOCAP® non-dispersive infrared sensor |
The repeatability and compensation specifications are defined at controlled reference conditions. Evaluate the complete uncertainty requirement for the incubator, including calibration uncertainty, long-term stability, compensation and gas-distribution effects.
| Condition | GMP231 specification | Practical requirement |
|---|---|---|
| Normal CO₂ measurement | 0 to +70 °C | Measurement electronics operate outside the incubator wall |
| Heat sterilisation | Sensor head withstands +180 °C | Probe must be in standby mode and installed according to Vaisala instructions |
| Maximum standby durability | Sensor head up to +195 °C | This is a durability limit, not a normal measurement temperature |
| Specified sterilisation endurance | At least 120 cycles at +180 °C | Record sterilisation exposure as part of the equipment maintenance history |
| Operating humidity | 0 to 100%, non-condensing | Heated optics reduce condensation risk during normal powered operation |
| Operating pressure | Below 1500 hPa | Configure pressure compensation to match the actual chamber condition |
| Influence | GMP231 capability | Why it matters |
|---|---|---|
| Temperature | Internal temperature measurement and compensation | Incubator measurement normally occurs close to +37 °C but varies during recovery and operation |
| Pressure | Internal pressure measurement with compensation from 500 to 1100 hPa | CO₂ gas density and indicated concentration change with atmospheric pressure |
| Humidity | Water-vapour compensation from 0 to 100 %RH | Incubators operate at high humidity, which changes the dry-gas fraction |
| Oxygen | Configurable compensation from 0 to 90% O₂ | Background-gas composition affects infrared CO₂ measurement |
Pressure and temperature are measured internally for compensation. Humidity and oxygen settings must match the intended chamber conditions. Incorrect compensation values can create a systematic error even when the probe is correctly calibrated.
| Specification | GMP231 |
|---|---|
| Digital outputs | I²C at 5 V and two-wire RS-485 with Vaisala Industrial Protocol |
| Analogue output | Scalable 0–20 mA; maximum load 600 Ω |
| Supply voltage | 11 to 30 V DC; 20 to 30 V DC when analogue output is used |
| Power consumption | Less than 1 W, pulsed |
| Connector | M12, 8-pin |
| Sensor-head protection | IP54 |
| Electronics-housing protection | IP20 |
| Probe-tube length | Approximately 118.5 mm |
| Weight | Approximately 150 g without cable; 200 g with cable |
| Probe-tube material | PPSU |
| Filter material | PTFE |
| Selection point | GMP231 | GMP251 | GMP80P with Indigo80 |
|---|---|---|---|
| Main purpose | Permanent OEM integration in CO₂ incubators | General percentage-level CO₂ measurement | Portable pump-aspirated incubator sampling |
| Measurement range | 0 to 20% CO₂ | 0 to 20% CO₂ | 0 to 20% CO₂ using GMP251 measurement technology |
| Design point | Optimized around 5% CO₂ and +37 °C | Flexible measurement across the full percentage-level range | Portable checks through sampling ports and tubing |
| Heat sterilisation | Sensor head remains installed during +180 °C cycles | Not designed as a permanent through-wall sterilisation probe | Portable equipment is removed before chamber sterilisation |
| Pressure measurement | Internal pressure sensor | Pressure value is configured for compensation | Pressure compensation is configured through the portable system |
| Outputs | I²C, Vaisala RS-485 protocol or 0–20 mA | Voltage, current, Modbus RTU or Vaisala protocol | Local Indigo80 display, logging and data transfer |
| Best choice when | The probe is built into an incubator and must survive sterilisation in place | A fixed general-purpose percentage-level probe is required | Technicians need portable sampling, checking or troubleshooting |
| Product information | GMP231 is detailed on this page | Explore Vaisala GMP251 | Explore Vaisala Indigo80 and GMP80P |
| Issue | Possible effect | Recommended response |
|---|---|---|
| Poor gas mixing | Probe reading does not represent the culture area | Review injection point, fan operation, recovery time and sensing location |
| Door opening | Temporary CO₂, temperature and humidity disturbance | Apply an appropriate control delay and evaluate recovery performance |
| Incorrect pressure compensation | Systematic CO₂ deviation | Use the internal pressure measurement and confirm the compensation configuration |
| Condensation | Slow recovery or unstable measurement | Keep the sensor powered where appropriate and review the chamber cycle |
| Repeated sterilisation | Long-term exposure and material ageing | Track cycle count and verify the probe according to the quality plan |
| Controller scaling mismatch | Incorrect displayed CO₂ value or control action | Verify the configured 0–20 mA scale at both the probe and controller |
GMP231 is supplied with a four-point traceable CO₂ calibration certificate. Field verification or adjustment can be performed using certified reference gas and supported Vaisala service equipment. The calibration plan should reflect incubator criticality, sterilisation exposure, quality requirements and the required uncertainty.
Seacom Process Instruments supplies and supports the Vaisala GMP231 Incubator CO₂ Probe in Malaysia for life-science incubators, laboratory equipment and OEM chamber integration.
Our team can help review the measurement range, incubator wall arrangement, sterilisation cycle, electrical interface, analogue scaling, environmental compensation and calibration requirement. We can also help compare permanent GMP231 integration with the general-purpose GMP251 or portable Indigo80/GMP80P sampling arrangement.
Planning a GMP231 installation? Send us the incubator design, normal CO₂ setpoint, sterilisation temperature and duration, wall thickness, supply voltage, controller interface, output requirement and calibration expectations.