Magnetic Flow Sensor

Aichi Tokei ND Flowsensor is ideal for measuring variety of fluid and outputs open collector pulses with the built-in amplifier type magnetic sensor.


Features

  • Highly accurate over a wide measurement range
  • Simple and durable structure
  • Compact and lightweight (eg. ND10: 120g)
  • Compatible with various kinds of fluids
  • Free installation position (except the position that of the holding plate is faced downward.)
  • Excellent cost-performance
  • High sensitive high-density pulse output




Overview

Item Model
ND05 -
TATAAA

ND05-
PATAAC
ND05-
NATAAC
ND10-
TATAAA
ND10-
PATAAA
ND10-
NATAAA
ND20-
PATAAA
ND20-
NATAAA
Flow-rate range 0.3 - 3 L/min 1.0 - 10L/min 1.5 - 20L/min 3.0 - 60L/min
Accuracy
(Standard installation position)
±2% (RS)
Pulse unit 2.5mL/p 7.69mL/p 25mL/p
Pressure drop 12 kPa or less
(At 3L/min)
15 kPa or less
(At 10L/min)
20 kPa or less
(At 20L/min)
60 kPa or less
(At 60L/min)
Fluid temperature range 0 to +60°C 0 to +70°C 0 to +60°C 0 to +70°C 0 to +60°C 0 to +70°C
Connection R 1/2 R 3/4
Weight Approx.150g Approx.120g Approx.360g



Common Specification

Maximum working pressure 1MPa or less with a fluid temperature of +20°C
Viscosity 0.5 to 1.5 mPa·s
Output signal Open collector pulse
4-wires, Lead-wire length approx. 600mm
Duty ratio 3/7 < A/B < 7/3
Impressed voltage range 3 to 15 V DC
Ambient temperature -20° to +80° (Dew condensation must be avoided)


Download


Specific References

You Might Also Like

.

1 other product in the same category:

.

back to top